If you made any changes in Pure these will be visible here soon.

Research Output 1998 2019

  • 331 Citations
  • 9 h-Index
  • 22 Article
  • 5 Conference contribution
  • 2 Paper
  • 1 Letter
Filter
Article
2019
1 Citation (Scopus)

Removal of airborne contamination in airborne infectious isolation rooms

Cho, J., Woo, K. & Kim, B., 2019 Feb 1, In : ASHRAE Journal. 61, 2, p. 8-21 14 p.

Research output: Contribution to journalArticle

Ventilation
Contamination
Air
Ventilation exhausts
Viruses
2018
6 Citations (Scopus)

Development of a data-driven predictive model of supply air temperature in an air-handling unit for conserving energy

Hong, G. & Kim, B. S., 2018 Feb, In : Energies. 11, 2, 407.

Research output: Contribution to journalArticle

Predictive Model
Data-driven
Unit
Air
Energy
2017
2 Citations (Scopus)

Experimental investigation on hygrothermal behaviour and the surface condensation risk of a data centre

Cho, J., Park, S., Lim, T. & Kim, B., 2017 Dec 1, In : Indoor and Built Environment. 26, 10, p. 1362-1381 20 p.

Research output: Contribution to journalArticle

Technology
Temperature
Humidity
Air
Air Conditioning
2016
3 Citations (Scopus)
Simulation Tool
Condensation
Experimental Investigation
Monitoring
Temperature
15 Citations (Scopus)

Field measurements of infiltration rate in high rise residential buildings using the constant concentration method

Hong, G. & Kim, B. S., 2016 Feb 15, In : Building and Environment. 97, p. 48-54 7 p.

Research output: Contribution to journalArticle

residential building
subversion
Infiltration
infiltration
Korea
2012
37 Citations (Scopus)

Viability of datacenter cooling systems for energy efficiency in temperate or subtropical regions: Case study

Cho, J., Lim, T. & Kim, B. S., 2012 Dec 1, In : Energy and Buildings. 55, p. 189-197 9 p.

Research output: Contribution to journalArticle

Economizers
Cooling systems
Energy efficiency
Humidity control
Water
2011
70 Citations (Scopus)

Evaluation of air management system's thermal performance for superior cooling efficiency in high-density data centers

Cho, J. & Kim, B. S., 2011 Sep 1, In : Energy and Buildings. 43, 9, p. 2145-2155 11 p.

Research output: Contribution to journalArticle

Cooling
Air
Servers
Ventilation exhausts
Hot Temperature
26 Citations (Scopus)

Predictions and measurements of the stack effect on indoor airborne virus transmission in a high-rise hospital building

Lim, T., Cho, J. & Kim, B. S., 2011 Dec 1, In : Building and Environment. 46, 12, p. 2413-2424 12 p.

Research output: Contribution to journalArticle

Viruses
building
virus
prediction
influenza
2010
11 Citations (Scopus)

A wind tunnel experiment and CFD analysis on airflow performance of enclosed-arcade markets in Korea

Kim, T., Kim, K. & Kim, B. S., 2010 May 1, In : Building and Environment. 45, 5, p. 1329-1338 10 p.

Research output: Contribution to journalArticle

dynamic analysis
computational fluid dynamics
wind tunnel
Dynamic analysis
airflow
4 Citations (Scopus)
Diffusers (fluid)
Viruses
Ventilation
Computational fluid dynamics
air
20 Citations (Scopus)

The predictions of infection risk of indoor airborne transmission of diseases in high-rise hospitals: Tracer gas simulation

Lim, T., Cho, J. & Kim, B. S., 2010 Aug 1, In : Energy and Buildings. 42, 8, p. 1172-1181 10 p.

Research output: Contribution to journalArticle

Gases
Viruses
Air
Diffusers (fluid)
Ventilation
2009
85 Citations (Scopus)

Measurements and predictions of the air distribution systems in high compute density (Internet) data centers

Cho, J., Lim, T. & Kim, B. S., 2009 Oct 1, In : Energy and Buildings. 41, 10, p. 1107-1115 9 p.

Research output: Contribution to journalArticle

Internet
Air
Cooling systems
Air intakes
Computational fluid dynamics
2008
10 Citations (Scopus)

Cooling systems for IT environment heat removal in (internet) data centers

Cho, J., Lim, T. & Kim, B. S., 2008 Jan 1, In : Journal of Asian Architecture and Building Engineering. 7, 2, p. 387-394 8 p.

Research output: Contribution to journalArticle

Cooling systems
heat
Internet
Cooling
Air
4 Citations (Scopus)

Survey and numerical effect analyses of the market structure and arcade form on the indoor environment of enclosed-arcade markets during summer

Kim, K., Park, S. & Kim, B., 2008 Oct 1, In : Solar Energy. 82, 10, p. 940-955 16 p.

Research output: Contribution to journalArticle

Roofs
Atmospheric humidity
Solar radiation
Temperature
Ventilation
2007
15 Citations (Scopus)

Analysis of design approaches to improve the comfort level of a small glazed-envelope building during summer

Kim, K., Kim, B. S. & Park, S., 2007 Jan 1, In : Solar Energy. 81, 1, p. 39-51 13 p.

Research output: Contribution to journalArticle

Luminance
Glare
Temperature
Architectural design
Computer simulation
1 Citation (Scopus)
Smoke
simulation
Computer simulation
market
performance
2006
2 Citations (Scopus)

Air Exchange Rate Analysis of the Arcade-Type Traditional Market Using Wind Tunnel Experiment and CFD Model

Kim, B. S., Roh, J., Kim, T., Kim, K. & Hong, G., 2006 Jan 1, In : Journal of Asian Architecture and Building Engineering. 5, 1, p. 161-167 7 p.

Research output: Contribution to journalArticle

Wind tunnels
Dynamic models
Computational fluid dynamics
air
experiment
5 Citations (Scopus)

The Indoor Environment Measurement Analysis of Arcade-Type Markets in Korea

Kim, B., Roh, J., Kim, T. & Kim, K., 2006 Jan 1, In : Journal of Asian Architecture and Building Engineering. 5, 1, p. 191-198 8 p.

Research output: Contribution to journalArticle

type of market
Air quality
Roofs
Korea
Ventilation
2004
1 Citation (Scopus)
Thermal insulation
Underground buildings
Earth (planet)
residential building
simulation
3 Citations (Scopus)
Skin
building
architect
energy
Glass
4 Citations (Scopus)
residential building
Condensation
conditioning
simulation model
Glass
1998
5 Citations (Scopus)

An interface system for computerized energy analyses for building designers

Kim, B. S. & Degelman, L. O., 1998 Feb 1, In : Energy and Buildings. 27, 1, p. 97-107 11 p.

Research output: Contribution to journalArticle

Cotton
User interfaces
Interfaces (computer)
Computer systems
Recovery