Purpose: Circumcision is widely practiced in Korea. Circumcision has been popularly performed with mechanical devices such as the Gomco clamp, the Plastibell device and other modified devices. We investigate the effect of using a new device (the circumcision clamp). Materials and Methods: We conducted a retrospective study between December 2003 and February 2004 on 75 patients who wanted circumcision. 25 patients were operated on by performing conventional circumcision, and 50 patients were operated on by using the circumcision clamp. Results: The mean operation time for the new device group was shorter than that for the conventional circumcision group (p < 0.05). No significant difference of complications was noted between the conventional circumcision group and the circumcision clamp group. Conclusions: The new method with using the circumcision clamp has a benefit as it is designed to expose the glans and it saves operating time.

Original languageEnglish
Pages (from-to)1099-1102
Number of pages4
JournalKorean Journal of Urology
Volume47
Issue number10
DOIs
Publication statusPublished - 2006 Jan 1

Fingerprint

Equipment and Supplies
Korea
Retrospective Studies

All Science Journal Classification (ASJC) codes

  • Urology

Cite this

Jung, Jaehung ; Lee, Sang Bong ; Song, Jae Mann. / A new convenient device of circumcision. In: Korean Journal of Urology. 2006 ; Vol. 47, No. 10. pp. 1099-1102.
@article{eb1f84276d84488987b743d9de30fc1b,
title = "A new convenient device of circumcision",
abstract = "Purpose: Circumcision is widely practiced in Korea. Circumcision has been popularly performed with mechanical devices such as the Gomco clamp, the Plastibell device and other modified devices. We investigate the effect of using a new device (the circumcision clamp). Materials and Methods: We conducted a retrospective study between December 2003 and February 2004 on 75 patients who wanted circumcision. 25 patients were operated on by performing conventional circumcision, and 50 patients were operated on by using the circumcision clamp. Results: The mean operation time for the new device group was shorter than that for the conventional circumcision group (p < 0.05). No significant difference of complications was noted between the conventional circumcision group and the circumcision clamp group. Conclusions: The new method with using the circumcision clamp has a benefit as it is designed to expose the glans and it saves operating time.",
author = "Jaehung Jung and Lee, {Sang Bong} and Song, {Jae Mann}",
year = "2006",
month = "1",
day = "1",
doi = "10.4111/kju.2006.47.10.1099",
language = "English",
volume = "47",
pages = "1099--1102",
journal = "Korean Journal of Urology",
issn = "2005-6737",
publisher = "Korean Urological Association",
number = "10",

}

A new convenient device of circumcision. / Jung, Jaehung; Lee, Sang Bong; Song, Jae Mann.

In: Korean Journal of Urology, Vol. 47, No. 10, 01.01.2006, p. 1099-1102.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A new convenient device of circumcision

AU - Jung, Jaehung

AU - Lee, Sang Bong

AU - Song, Jae Mann

PY - 2006/1/1

Y1 - 2006/1/1

N2 - Purpose: Circumcision is widely practiced in Korea. Circumcision has been popularly performed with mechanical devices such as the Gomco clamp, the Plastibell device and other modified devices. We investigate the effect of using a new device (the circumcision clamp). Materials and Methods: We conducted a retrospective study between December 2003 and February 2004 on 75 patients who wanted circumcision. 25 patients were operated on by performing conventional circumcision, and 50 patients were operated on by using the circumcision clamp. Results: The mean operation time for the new device group was shorter than that for the conventional circumcision group (p < 0.05). No significant difference of complications was noted between the conventional circumcision group and the circumcision clamp group. Conclusions: The new method with using the circumcision clamp has a benefit as it is designed to expose the glans and it saves operating time.

AB - Purpose: Circumcision is widely practiced in Korea. Circumcision has been popularly performed with mechanical devices such as the Gomco clamp, the Plastibell device and other modified devices. We investigate the effect of using a new device (the circumcision clamp). Materials and Methods: We conducted a retrospective study between December 2003 and February 2004 on 75 patients who wanted circumcision. 25 patients were operated on by performing conventional circumcision, and 50 patients were operated on by using the circumcision clamp. Results: The mean operation time for the new device group was shorter than that for the conventional circumcision group (p < 0.05). No significant difference of complications was noted between the conventional circumcision group and the circumcision clamp group. Conclusions: The new method with using the circumcision clamp has a benefit as it is designed to expose the glans and it saves operating time.

UR - http://www.scopus.com/inward/record.url?scp=33751361991&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33751361991&partnerID=8YFLogxK

U2 - 10.4111/kju.2006.47.10.1099

DO - 10.4111/kju.2006.47.10.1099

M3 - Article

VL - 47

SP - 1099

EP - 1102

JO - Korean Journal of Urology

JF - Korean Journal of Urology

SN - 2005-6737

IS - 10

ER -