Abstract

A new micro biosensor has been proposed and fabricated for the measurement of glucose concentration in whole blood. The proposed micro biosensor has been monolithically integrated with enzymatic metal microelectrode array in a micromachined chamber attached to a microsyringe. The fabricated micro biosensor has a high sensitivity of 470 nA/cm2·mM for detecting glucose levels in a wide linear range of 0∼50 mM in photassium phosphate buffer solution (pH7.0).

Original languageEnglish
Pages443-446
Number of pages4
Publication statusPublished - 2001 Jan 1
Event14th IEEE International Conference on Micro Electro Mechanical Systems (MEMS 2001) - Interlaken, Switzerland
Duration: 2001 Jan 212001 Jan 25

Conference

Conference14th IEEE International Conference on Micro Electro Mechanical Systems (MEMS 2001)
CountrySwitzerland
CityInterlaken
Period01/1/2101/1/25

Fingerprint

Biosensors
Blood
Glucose
Microelectrodes
Phosphates
Metals

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Mechanical Engineering
  • Electrical and Electronic Engineering

Cite this

Kim, J. H., Kim, B. G., Yoon, E., & Han, C. H. (2001). A new monolithic micro biosensor for blood analysis. 443-446. Paper presented at 14th IEEE International Conference on Micro Electro Mechanical Systems (MEMS 2001), Interlaken, Switzerland.
Kim, J. H. ; Kim, B. G. ; Yoon, E. ; Han, C. H. / A new monolithic micro biosensor for blood analysis. Paper presented at 14th IEEE International Conference on Micro Electro Mechanical Systems (MEMS 2001), Interlaken, Switzerland.4 p.
@conference{a20ea37a55c24b31847c3fa646c7ba9b,
title = "A new monolithic micro biosensor for blood analysis",
abstract = "A new micro biosensor has been proposed and fabricated for the measurement of glucose concentration in whole blood. The proposed micro biosensor has been monolithically integrated with enzymatic metal microelectrode array in a micromachined chamber attached to a microsyringe. The fabricated micro biosensor has a high sensitivity of 470 nA/cm2·mM for detecting glucose levels in a wide linear range of 0∼50 mM in photassium phosphate buffer solution (pH7.0).",
author = "Kim, {J. H.} and Kim, {B. G.} and E. Yoon and Han, {C. H.}",
year = "2001",
month = "1",
day = "1",
language = "English",
pages = "443--446",
note = "14th IEEE International Conference on Micro Electro Mechanical Systems (MEMS 2001) ; Conference date: 21-01-2001 Through 25-01-2001",

}

Kim, JH, Kim, BG, Yoon, E & Han, CH 2001, 'A new monolithic micro biosensor for blood analysis', Paper presented at 14th IEEE International Conference on Micro Electro Mechanical Systems (MEMS 2001), Interlaken, Switzerland, 01/1/21 - 01/1/25 pp. 443-446.

A new monolithic micro biosensor for blood analysis. / Kim, J. H.; Kim, B. G.; Yoon, E.; Han, C. H.

2001. 443-446 Paper presented at 14th IEEE International Conference on Micro Electro Mechanical Systems (MEMS 2001), Interlaken, Switzerland.

Research output: Contribution to conferencePaper

TY - CONF

T1 - A new monolithic micro biosensor for blood analysis

AU - Kim, J. H.

AU - Kim, B. G.

AU - Yoon, E.

AU - Han, C. H.

PY - 2001/1/1

Y1 - 2001/1/1

N2 - A new micro biosensor has been proposed and fabricated for the measurement of glucose concentration in whole blood. The proposed micro biosensor has been monolithically integrated with enzymatic metal microelectrode array in a micromachined chamber attached to a microsyringe. The fabricated micro biosensor has a high sensitivity of 470 nA/cm2·mM for detecting glucose levels in a wide linear range of 0∼50 mM in photassium phosphate buffer solution (pH7.0).

AB - A new micro biosensor has been proposed and fabricated for the measurement of glucose concentration in whole blood. The proposed micro biosensor has been monolithically integrated with enzymatic metal microelectrode array in a micromachined chamber attached to a microsyringe. The fabricated micro biosensor has a high sensitivity of 470 nA/cm2·mM for detecting glucose levels in a wide linear range of 0∼50 mM in photassium phosphate buffer solution (pH7.0).

UR - http://www.scopus.com/inward/record.url?scp=0034996186&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034996186&partnerID=8YFLogxK

M3 - Paper

AN - SCOPUS:0034996186

SP - 443

EP - 446

ER -

Kim JH, Kim BG, Yoon E, Han CH. A new monolithic micro biosensor for blood analysis. 2001. Paper presented at 14th IEEE International Conference on Micro Electro Mechanical Systems (MEMS 2001), Interlaken, Switzerland.