A novel modification of double stapling technique in Billroth I anastomosis

Yeong An Ji, Ho Yoon Seok, Ho Pak Kyung, Geon Ung Heo, Jin Oh Sung, Jin Hyung Woo, Hoon Noh Sung

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Although the double-stapling technique has been used as a safe procedure in gastroduodenostomy, creating anastomosis with a circular stapler on the linear stapler line can be vulnerable for anastomotic leakage and ischemia. Therefore, we tried to modify the double-stapling technique to avoid stapling on the staple line.

Original languageEnglish
Pages (from-to)518-519
Number of pages2
JournalJournal of surgical oncology
Volume100
Issue number6
DOIs
Publication statusPublished - 2009 Nov 1

Fingerprint

Gastroenterostomy
Anastomotic Leak
Ischemia

All Science Journal Classification (ASJC) codes

  • Surgery
  • Oncology

Cite this

Ji, Y. A., Seok, H. Y., Kyung, H. P., Heo, G. U., Sung, J. O., Woo, J. H., & Sung, H. N. (2009). A novel modification of double stapling technique in Billroth I anastomosis. Journal of surgical oncology, 100(6), 518-519. https://doi.org/10.1002/jso.21368
Ji, Yeong An ; Seok, Ho Yoon ; Kyung, Ho Pak ; Heo, Geon Ung ; Sung, Jin Oh ; Woo, Jin Hyung ; Sung, Hoon Noh. / A novel modification of double stapling technique in Billroth I anastomosis. In: Journal of surgical oncology. 2009 ; Vol. 100, No. 6. pp. 518-519.
@article{ebc7cbf2145743e2890d5f6e9f75f902,
title = "A novel modification of double stapling technique in Billroth I anastomosis",
abstract = "Although the double-stapling technique has been used as a safe procedure in gastroduodenostomy, creating anastomosis with a circular stapler on the linear stapler line can be vulnerable for anastomotic leakage and ischemia. Therefore, we tried to modify the double-stapling technique to avoid stapling on the staple line.",
author = "Ji, {Yeong An} and Seok, {Ho Yoon} and Kyung, {Ho Pak} and Heo, {Geon Ung} and Sung, {Jin Oh} and Woo, {Jin Hyung} and Sung, {Hoon Noh}",
year = "2009",
month = "11",
day = "1",
doi = "10.1002/jso.21368",
language = "English",
volume = "100",
pages = "518--519",
journal = "Journal of Surgical Oncology",
issn = "0022-4790",
publisher = "Wiley-Liss Inc.",
number = "6",

}

Ji, YA, Seok, HY, Kyung, HP, Heo, GU, Sung, JO, Woo, JH & Sung, HN 2009, 'A novel modification of double stapling technique in Billroth I anastomosis', Journal of surgical oncology, vol. 100, no. 6, pp. 518-519. https://doi.org/10.1002/jso.21368

A novel modification of double stapling technique in Billroth I anastomosis. / Ji, Yeong An; Seok, Ho Yoon; Kyung, Ho Pak; Heo, Geon Ung; Sung, Jin Oh; Woo, Jin Hyung; Sung, Hoon Noh.

In: Journal of surgical oncology, Vol. 100, No. 6, 01.11.2009, p. 518-519.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A novel modification of double stapling technique in Billroth I anastomosis

AU - Ji, Yeong An

AU - Seok, Ho Yoon

AU - Kyung, Ho Pak

AU - Heo, Geon Ung

AU - Sung, Jin Oh

AU - Woo, Jin Hyung

AU - Sung, Hoon Noh

PY - 2009/11/1

Y1 - 2009/11/1

N2 - Although the double-stapling technique has been used as a safe procedure in gastroduodenostomy, creating anastomosis with a circular stapler on the linear stapler line can be vulnerable for anastomotic leakage and ischemia. Therefore, we tried to modify the double-stapling technique to avoid stapling on the staple line.

AB - Although the double-stapling technique has been used as a safe procedure in gastroduodenostomy, creating anastomosis with a circular stapler on the linear stapler line can be vulnerable for anastomotic leakage and ischemia. Therefore, we tried to modify the double-stapling technique to avoid stapling on the staple line.

UR - http://www.scopus.com/inward/record.url?scp=70350324051&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70350324051&partnerID=8YFLogxK

U2 - 10.1002/jso.21368

DO - 10.1002/jso.21368

M3 - Article

C2 - 19697394

AN - SCOPUS:70350324051

VL - 100

SP - 518

EP - 519

JO - Journal of Surgical Oncology

JF - Journal of Surgical Oncology

SN - 0022-4790

IS - 6

ER -