An automated and semi-continuous method for the analysis of water-soluble constituents in PM2.5

B. K. Lee, Y. H. Kim, D. S. Lee

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

An automated and semi-continuous method for measuring water-soluble constituents in PM2.5 was developed. The system consists of a multi-tube diffusion scrubber (MTDS), a low temperature particle impactor (LTPI), an inertial air/liquid separator, and two ion chromatography systems. The MTDS acts as an interfering gas removal system and also as a humidifier for growing particles. Since the MTDS operates at 40 °C, the loss of volatile compounds and hydrological conversion of nitrogen oxides to nitrite were not of significant concern. The condensation of water vapor, dissolution of soluble constituents, and capture of insoluble particles occurred in the LTPI. The condensed liquid containing the dissolved species and the insoluble particles was separated from the airflow using an inertial air/liquid separator. The analysis of cations and anions in the effluent liquid was performed using two ion chromatography systems. The collection efficiency, including the inlet loss, of the system was 96.6 ± 7.1% at an air flow rate of 1.0 SLPM. The limits of detection ranged from 12 to 57 ng/m3 for major ionic constituents without any pre-concentration procedure. This method was tested in the field and the average data capture was over 90%, demonstrating the reliability of the system.

Original languageEnglish
Pages (from-to)145-153
Number of pages9
JournalScience of the Total Environment
Volume393
Issue number1
DOIs
Publication statusPublished - 2008 Apr 1

Fingerprint

Scrubbers
Ion chromatography
Water
Liquids
Separators
liquid
ion chromatography
Air
airflow
Nitrogen Oxides
water
Steam
Nitrogen oxides
Nitrites
Water vapor
Anions
Cations
air
Effluents
Condensation

All Science Journal Classification (ASJC) codes

  • Environmental Engineering
  • Environmental Chemistry
  • Waste Management and Disposal
  • Pollution

Cite this

@article{1658ccdc066c414aa46cd33925d316d5,
title = "An automated and semi-continuous method for the analysis of water-soluble constituents in PM2.5",
abstract = "An automated and semi-continuous method for measuring water-soluble constituents in PM2.5 was developed. The system consists of a multi-tube diffusion scrubber (MTDS), a low temperature particle impactor (LTPI), an inertial air/liquid separator, and two ion chromatography systems. The MTDS acts as an interfering gas removal system and also as a humidifier for growing particles. Since the MTDS operates at 40 °C, the loss of volatile compounds and hydrological conversion of nitrogen oxides to nitrite were not of significant concern. The condensation of water vapor, dissolution of soluble constituents, and capture of insoluble particles occurred in the LTPI. The condensed liquid containing the dissolved species and the insoluble particles was separated from the airflow using an inertial air/liquid separator. The analysis of cations and anions in the effluent liquid was performed using two ion chromatography systems. The collection efficiency, including the inlet loss, of the system was 96.6 ± 7.1{\%} at an air flow rate of 1.0 SLPM. The limits of detection ranged from 12 to 57 ng/m3 for major ionic constituents without any pre-concentration procedure. This method was tested in the field and the average data capture was over 90{\%}, demonstrating the reliability of the system.",
author = "Lee, {B. K.} and Kim, {Y. H.} and Lee, {D. S.}",
year = "2008",
month = "4",
day = "1",
doi = "10.1016/j.scitotenv.2007.11.035",
language = "English",
volume = "393",
pages = "145--153",
journal = "Science of the Total Environment",
issn = "0048-9697",
publisher = "Elsevier",
number = "1",

}

An automated and semi-continuous method for the analysis of water-soluble constituents in PM2.5. / Lee, B. K.; Kim, Y. H.; Lee, D. S.

In: Science of the Total Environment, Vol. 393, No. 1, 01.04.2008, p. 145-153.

Research output: Contribution to journalArticle

TY - JOUR

T1 - An automated and semi-continuous method for the analysis of water-soluble constituents in PM2.5

AU - Lee, B. K.

AU - Kim, Y. H.

AU - Lee, D. S.

PY - 2008/4/1

Y1 - 2008/4/1

N2 - An automated and semi-continuous method for measuring water-soluble constituents in PM2.5 was developed. The system consists of a multi-tube diffusion scrubber (MTDS), a low temperature particle impactor (LTPI), an inertial air/liquid separator, and two ion chromatography systems. The MTDS acts as an interfering gas removal system and also as a humidifier for growing particles. Since the MTDS operates at 40 °C, the loss of volatile compounds and hydrological conversion of nitrogen oxides to nitrite were not of significant concern. The condensation of water vapor, dissolution of soluble constituents, and capture of insoluble particles occurred in the LTPI. The condensed liquid containing the dissolved species and the insoluble particles was separated from the airflow using an inertial air/liquid separator. The analysis of cations and anions in the effluent liquid was performed using two ion chromatography systems. The collection efficiency, including the inlet loss, of the system was 96.6 ± 7.1% at an air flow rate of 1.0 SLPM. The limits of detection ranged from 12 to 57 ng/m3 for major ionic constituents without any pre-concentration procedure. This method was tested in the field and the average data capture was over 90%, demonstrating the reliability of the system.

AB - An automated and semi-continuous method for measuring water-soluble constituents in PM2.5 was developed. The system consists of a multi-tube diffusion scrubber (MTDS), a low temperature particle impactor (LTPI), an inertial air/liquid separator, and two ion chromatography systems. The MTDS acts as an interfering gas removal system and also as a humidifier for growing particles. Since the MTDS operates at 40 °C, the loss of volatile compounds and hydrological conversion of nitrogen oxides to nitrite were not of significant concern. The condensation of water vapor, dissolution of soluble constituents, and capture of insoluble particles occurred in the LTPI. The condensed liquid containing the dissolved species and the insoluble particles was separated from the airflow using an inertial air/liquid separator. The analysis of cations and anions in the effluent liquid was performed using two ion chromatography systems. The collection efficiency, including the inlet loss, of the system was 96.6 ± 7.1% at an air flow rate of 1.0 SLPM. The limits of detection ranged from 12 to 57 ng/m3 for major ionic constituents without any pre-concentration procedure. This method was tested in the field and the average data capture was over 90%, demonstrating the reliability of the system.

UR - http://www.scopus.com/inward/record.url?scp=39149093356&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=39149093356&partnerID=8YFLogxK

U2 - 10.1016/j.scitotenv.2007.11.035

DO - 10.1016/j.scitotenv.2007.11.035

M3 - Article

C2 - 18237764

AN - SCOPUS:39149093356

VL - 393

SP - 145

EP - 153

JO - Science of the Total Environment

JF - Science of the Total Environment

SN - 0048-9697

IS - 1

ER -