An electrodynamic preconcentrator integrated thermoelectric biosensor chip for continuous monitoring of biochemical process

Yong Hwan Choi, Min Gu Kim, Dong Hyun Kang, Jaesam Sim, Jongbaeg Kim, Yong Jun Kim

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

This paper proposes an integrated sensor chip for continuous monitoring of a biochemical process. It is composed of a preconcentrator and a thermoelectric biosensor. In the preconcentrator, the concentration of the injected biochemical sample is electrodynamically condensed. Then, in the downstream thermoelectric biosensor, the preconcentrated target molecules react with sequentially injected capture molecules and generate reaction heat. The reaction heat is detected based on the thermoelectric effect, and an integrated split-flow microchannel improves the sensor stability by providing ability to self-compensate thermal noise. These sequential preconcentration and detection processes are performed in completely label-free and continuous conditions and consequently enhance the sensor sensitivity. The performance of the integrated biosensor chip was evaluated at various flow rates and applied voltages. First, in order to verify characteristics of the fabricated preconcentrator, 10 m -diameter polystyrene (PS) particles were used. The particles were concentrated by applying ac voltage from 0 to 16 Vpp at 3 MHz at various flow rates. In the experimental result, approximately 92.8% of concentration efficiency was achieved at a voltage over 16 Vpp and at a flow rate below 100 l h-1. The downstream thermoelectric biosensor was characterized by measuring reaction heat of biotin-streptavidin interaction. The preconcentrated streptavidin-coated PS particles flow into the reaction chamber and react with titrated biotin. The measured output voltage was 288.2 V at a flow rate of 100 l h-1 without preconcentration. However, by using proposed preconcentrator, an output voltage of 812.3 V was achieved with a 16 Vpp-applied preconcentration in the same given sample and flow rate. According to these results, the proposed label-free biomolecular preconcentration and detection technique can be applied in continuous and high-throughput biochemical applications.

Original languageEnglish
Article number045022
JournalJournal of Micromechanics and Microengineering
Volume22
Issue number4
DOIs
Publication statusPublished - 2012 Apr 1

Fingerprint

Electrodynamics
Biosensors
Flow rate
Monitoring
Electric potential
Streptavidin
Polystyrenes
Biotin
Labels
Sensors
Thermoelectricity
Molecules
Thermal noise
Microchannels
Throughput
Hot Temperature

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Mechanics of Materials
  • Mechanical Engineering
  • Electrical and Electronic Engineering

Cite this

@article{3135bf588c584a93b07ea8adfcc189a9,
title = "An electrodynamic preconcentrator integrated thermoelectric biosensor chip for continuous monitoring of biochemical process",
abstract = "This paper proposes an integrated sensor chip for continuous monitoring of a biochemical process. It is composed of a preconcentrator and a thermoelectric biosensor. In the preconcentrator, the concentration of the injected biochemical sample is electrodynamically condensed. Then, in the downstream thermoelectric biosensor, the preconcentrated target molecules react with sequentially injected capture molecules and generate reaction heat. The reaction heat is detected based on the thermoelectric effect, and an integrated split-flow microchannel improves the sensor stability by providing ability to self-compensate thermal noise. These sequential preconcentration and detection processes are performed in completely label-free and continuous conditions and consequently enhance the sensor sensitivity. The performance of the integrated biosensor chip was evaluated at various flow rates and applied voltages. First, in order to verify characteristics of the fabricated preconcentrator, 10 m -diameter polystyrene (PS) particles were used. The particles were concentrated by applying ac voltage from 0 to 16 Vpp at 3 MHz at various flow rates. In the experimental result, approximately 92.8{\%} of concentration efficiency was achieved at a voltage over 16 Vpp and at a flow rate below 100 l h-1. The downstream thermoelectric biosensor was characterized by measuring reaction heat of biotin-streptavidin interaction. The preconcentrated streptavidin-coated PS particles flow into the reaction chamber and react with titrated biotin. The measured output voltage was 288.2 V at a flow rate of 100 l h-1 without preconcentration. However, by using proposed preconcentrator, an output voltage of 812.3 V was achieved with a 16 Vpp-applied preconcentration in the same given sample and flow rate. According to these results, the proposed label-free biomolecular preconcentration and detection technique can be applied in continuous and high-throughput biochemical applications.",
author = "Choi, {Yong Hwan} and Kim, {Min Gu} and Kang, {Dong Hyun} and Jaesam Sim and Jongbaeg Kim and Kim, {Yong Jun}",
year = "2012",
month = "4",
day = "1",
doi = "10.1088/0960-1317/22/4/045022",
language = "English",
volume = "22",
journal = "Journal of Micromechanics and Microengineering",
issn = "0960-1317",
publisher = "IOP Publishing Ltd.",
number = "4",

}

An electrodynamic preconcentrator integrated thermoelectric biosensor chip for continuous monitoring of biochemical process. / Choi, Yong Hwan; Kim, Min Gu; Kang, Dong Hyun; Sim, Jaesam; Kim, Jongbaeg; Kim, Yong Jun.

In: Journal of Micromechanics and Microengineering, Vol. 22, No. 4, 045022, 01.04.2012.

Research output: Contribution to journalArticle

TY - JOUR

T1 - An electrodynamic preconcentrator integrated thermoelectric biosensor chip for continuous monitoring of biochemical process

AU - Choi, Yong Hwan

AU - Kim, Min Gu

AU - Kang, Dong Hyun

AU - Sim, Jaesam

AU - Kim, Jongbaeg

AU - Kim, Yong Jun

PY - 2012/4/1

Y1 - 2012/4/1

N2 - This paper proposes an integrated sensor chip for continuous monitoring of a biochemical process. It is composed of a preconcentrator and a thermoelectric biosensor. In the preconcentrator, the concentration of the injected biochemical sample is electrodynamically condensed. Then, in the downstream thermoelectric biosensor, the preconcentrated target molecules react with sequentially injected capture molecules and generate reaction heat. The reaction heat is detected based on the thermoelectric effect, and an integrated split-flow microchannel improves the sensor stability by providing ability to self-compensate thermal noise. These sequential preconcentration and detection processes are performed in completely label-free and continuous conditions and consequently enhance the sensor sensitivity. The performance of the integrated biosensor chip was evaluated at various flow rates and applied voltages. First, in order to verify characteristics of the fabricated preconcentrator, 10 m -diameter polystyrene (PS) particles were used. The particles were concentrated by applying ac voltage from 0 to 16 Vpp at 3 MHz at various flow rates. In the experimental result, approximately 92.8% of concentration efficiency was achieved at a voltage over 16 Vpp and at a flow rate below 100 l h-1. The downstream thermoelectric biosensor was characterized by measuring reaction heat of biotin-streptavidin interaction. The preconcentrated streptavidin-coated PS particles flow into the reaction chamber and react with titrated biotin. The measured output voltage was 288.2 V at a flow rate of 100 l h-1 without preconcentration. However, by using proposed preconcentrator, an output voltage of 812.3 V was achieved with a 16 Vpp-applied preconcentration in the same given sample and flow rate. According to these results, the proposed label-free biomolecular preconcentration and detection technique can be applied in continuous and high-throughput biochemical applications.

AB - This paper proposes an integrated sensor chip for continuous monitoring of a biochemical process. It is composed of a preconcentrator and a thermoelectric biosensor. In the preconcentrator, the concentration of the injected biochemical sample is electrodynamically condensed. Then, in the downstream thermoelectric biosensor, the preconcentrated target molecules react with sequentially injected capture molecules and generate reaction heat. The reaction heat is detected based on the thermoelectric effect, and an integrated split-flow microchannel improves the sensor stability by providing ability to self-compensate thermal noise. These sequential preconcentration and detection processes are performed in completely label-free and continuous conditions and consequently enhance the sensor sensitivity. The performance of the integrated biosensor chip was evaluated at various flow rates and applied voltages. First, in order to verify characteristics of the fabricated preconcentrator, 10 m -diameter polystyrene (PS) particles were used. The particles were concentrated by applying ac voltage from 0 to 16 Vpp at 3 MHz at various flow rates. In the experimental result, approximately 92.8% of concentration efficiency was achieved at a voltage over 16 Vpp and at a flow rate below 100 l h-1. The downstream thermoelectric biosensor was characterized by measuring reaction heat of biotin-streptavidin interaction. The preconcentrated streptavidin-coated PS particles flow into the reaction chamber and react with titrated biotin. The measured output voltage was 288.2 V at a flow rate of 100 l h-1 without preconcentration. However, by using proposed preconcentrator, an output voltage of 812.3 V was achieved with a 16 Vpp-applied preconcentration in the same given sample and flow rate. According to these results, the proposed label-free biomolecular preconcentration and detection technique can be applied in continuous and high-throughput biochemical applications.

UR - http://www.scopus.com/inward/record.url?scp=84878129244&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84878129244&partnerID=8YFLogxK

U2 - 10.1088/0960-1317/22/4/045022

DO - 10.1088/0960-1317/22/4/045022

M3 - Article

AN - SCOPUS:84878129244

VL - 22

JO - Journal of Micromechanics and Microengineering

JF - Journal of Micromechanics and Microengineering

SN - 0960-1317

IS - 4

M1 - 045022