Analog single-photon counter for high-speed scanning microscopy

Sucbei Moon, Dug Young Kim

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

We introduce a novel single-photon sensitive photodetection method of analog single-photon counting (SPC) for the application of high-speed scanning microscopy that requires high measurement speed and wide dynamic range for the photodetector. This scheme is based on analog electronic circuits which can perform proper differentiation and integration operations before and after discrimination of the analog signal from the photomultiplier tube (PMT), respectively. In spite of its simpler implementation, our analog SPC scheme exhibits good sensitivity and operation stability. Related with the dynamic range, the maximum count rate of our analog SPC is significantly improved due to the fast operation of the analog circuitry. This characteristic of the higher counting rate makes this scheme very suitable for high-speed scanning microscopy. It has also been demonstrated that the afterpulsing problem of an analog-mode PMT is the major noise source that degrades the image quality in the application of scanning microscopy, and our SPC scheme successfully neutralizes this kind of impulse noises to obtain a nearly shot-noise-limited imaging performance.

Original languageEnglish
Pages (from-to)13990-14003
Number of pages14
JournalOptics Express
Volume16
Issue number18
DOIs
Publication statusPublished - 2008 Sep 1

Fingerprint

counters
high speed
analogs
microscopy
scanning
counting
photons
photomultiplier tubes
dynamic range
shot noise
photometers
discrimination
impulses
sensitivity
electronics

All Science Journal Classification (ASJC) codes

  • Atomic and Molecular Physics, and Optics

Cite this

Moon, Sucbei ; Kim, Dug Young. / Analog single-photon counter for high-speed scanning microscopy. In: Optics Express. 2008 ; Vol. 16, No. 18. pp. 13990-14003.
@article{7a74b5b6719146c9bc840e341a7a64e9,
title = "Analog single-photon counter for high-speed scanning microscopy",
abstract = "We introduce a novel single-photon sensitive photodetection method of analog single-photon counting (SPC) for the application of high-speed scanning microscopy that requires high measurement speed and wide dynamic range for the photodetector. This scheme is based on analog electronic circuits which can perform proper differentiation and integration operations before and after discrimination of the analog signal from the photomultiplier tube (PMT), respectively. In spite of its simpler implementation, our analog SPC scheme exhibits good sensitivity and operation stability. Related with the dynamic range, the maximum count rate of our analog SPC is significantly improved due to the fast operation of the analog circuitry. This characteristic of the higher counting rate makes this scheme very suitable for high-speed scanning microscopy. It has also been demonstrated that the afterpulsing problem of an analog-mode PMT is the major noise source that degrades the image quality in the application of scanning microscopy, and our SPC scheme successfully neutralizes this kind of impulse noises to obtain a nearly shot-noise-limited imaging performance.",
author = "Sucbei Moon and Kim, {Dug Young}",
year = "2008",
month = "9",
day = "1",
doi = "10.1364/OE.16.013990",
language = "English",
volume = "16",
pages = "13990--14003",
journal = "Optics Express",
issn = "1094-4087",
publisher = "The Optical Society",
number = "18",

}

Analog single-photon counter for high-speed scanning microscopy. / Moon, Sucbei; Kim, Dug Young.

In: Optics Express, Vol. 16, No. 18, 01.09.2008, p. 13990-14003.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Analog single-photon counter for high-speed scanning microscopy

AU - Moon, Sucbei

AU - Kim, Dug Young

PY - 2008/9/1

Y1 - 2008/9/1

N2 - We introduce a novel single-photon sensitive photodetection method of analog single-photon counting (SPC) for the application of high-speed scanning microscopy that requires high measurement speed and wide dynamic range for the photodetector. This scheme is based on analog electronic circuits which can perform proper differentiation and integration operations before and after discrimination of the analog signal from the photomultiplier tube (PMT), respectively. In spite of its simpler implementation, our analog SPC scheme exhibits good sensitivity and operation stability. Related with the dynamic range, the maximum count rate of our analog SPC is significantly improved due to the fast operation of the analog circuitry. This characteristic of the higher counting rate makes this scheme very suitable for high-speed scanning microscopy. It has also been demonstrated that the afterpulsing problem of an analog-mode PMT is the major noise source that degrades the image quality in the application of scanning microscopy, and our SPC scheme successfully neutralizes this kind of impulse noises to obtain a nearly shot-noise-limited imaging performance.

AB - We introduce a novel single-photon sensitive photodetection method of analog single-photon counting (SPC) for the application of high-speed scanning microscopy that requires high measurement speed and wide dynamic range for the photodetector. This scheme is based on analog electronic circuits which can perform proper differentiation and integration operations before and after discrimination of the analog signal from the photomultiplier tube (PMT), respectively. In spite of its simpler implementation, our analog SPC scheme exhibits good sensitivity and operation stability. Related with the dynamic range, the maximum count rate of our analog SPC is significantly improved due to the fast operation of the analog circuitry. This characteristic of the higher counting rate makes this scheme very suitable for high-speed scanning microscopy. It has also been demonstrated that the afterpulsing problem of an analog-mode PMT is the major noise source that degrades the image quality in the application of scanning microscopy, and our SPC scheme successfully neutralizes this kind of impulse noises to obtain a nearly shot-noise-limited imaging performance.

UR - http://www.scopus.com/inward/record.url?scp=51149123248&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=51149123248&partnerID=8YFLogxK

U2 - 10.1364/OE.16.013990

DO - 10.1364/OE.16.013990

M3 - Article

VL - 16

SP - 13990

EP - 14003

JO - Optics Express

JF - Optics Express

SN - 1094-4087

IS - 18

ER -