Analysis of the shear behavior of stubby Y-type perfobond rib shear connectors for a composite frame structure

Sang Hyo Kim, Kun Soo Kim, Do Hoon Lee, Jun Seung Park, Oneil Han

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Shear connectors are used in steel beam-concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of building structures. Thus, this paper proposes stubby Y-type perfobond rib shear connectors, redefining the existing connectors, for composite frames of building structures; these were used to perform push-out tests. These shear connectors have relatively small ribs compared to the conventional Y-type perfobond rib shear connectors. To confirm the shear resistance of these stubby shear connectors, we performed an experiment by using transverse rebars D13 and D16. The results indicate that these shear connectors have suitable shear strength and ductility for application in composite frame structures. The shear strengths obtained using D13 and D16 were not significantly different. However, the ductility of the shear connectors with D16 was 45.1% higher than that of the shear connectors with D13.

Original languageEnglish
Article number1340
JournalMaterials
Volume10
Issue number11
DOIs
Publication statusPublished - 2017 Nov 22

Fingerprint

Composite materials
Shear strength
Ductility
Composite bridges
Concrete slabs
Steel
Experiments

All Science Journal Classification (ASJC) codes

  • Materials Science(all)

Cite this

Kim, Sang Hyo ; Kim, Kun Soo ; Lee, Do Hoon ; Park, Jun Seung ; Han, Oneil. / Analysis of the shear behavior of stubby Y-type perfobond rib shear connectors for a composite frame structure. In: Materials. 2017 ; Vol. 10, No. 11.
@article{e1dc870883c241ff9427f21ffa7bf629,
title = "Analysis of the shear behavior of stubby Y-type perfobond rib shear connectors for a composite frame structure",
abstract = "Shear connectors are used in steel beam-concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of building structures. Thus, this paper proposes stubby Y-type perfobond rib shear connectors, redefining the existing connectors, for composite frames of building structures; these were used to perform push-out tests. These shear connectors have relatively small ribs compared to the conventional Y-type perfobond rib shear connectors. To confirm the shear resistance of these stubby shear connectors, we performed an experiment by using transverse rebars D13 and D16. The results indicate that these shear connectors have suitable shear strength and ductility for application in composite frame structures. The shear strengths obtained using D13 and D16 were not significantly different. However, the ductility of the shear connectors with D16 was 45.1{\%} higher than that of the shear connectors with D13.",
author = "Kim, {Sang Hyo} and Kim, {Kun Soo} and Lee, {Do Hoon} and Park, {Jun Seung} and Oneil Han",
year = "2017",
month = "11",
day = "22",
doi = "10.3390/ma10111340",
language = "English",
volume = "10",
journal = "Materials",
issn = "1996-1944",
publisher = "MDPI AG",
number = "11",

}

Analysis of the shear behavior of stubby Y-type perfobond rib shear connectors for a composite frame structure. / Kim, Sang Hyo; Kim, Kun Soo; Lee, Do Hoon; Park, Jun Seung; Han, Oneil.

In: Materials, Vol. 10, No. 11, 1340, 22.11.2017.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Analysis of the shear behavior of stubby Y-type perfobond rib shear connectors for a composite frame structure

AU - Kim, Sang Hyo

AU - Kim, Kun Soo

AU - Lee, Do Hoon

AU - Park, Jun Seung

AU - Han, Oneil

PY - 2017/11/22

Y1 - 2017/11/22

N2 - Shear connectors are used in steel beam-concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of building structures. Thus, this paper proposes stubby Y-type perfobond rib shear connectors, redefining the existing connectors, for composite frames of building structures; these were used to perform push-out tests. These shear connectors have relatively small ribs compared to the conventional Y-type perfobond rib shear connectors. To confirm the shear resistance of these stubby shear connectors, we performed an experiment by using transverse rebars D13 and D16. The results indicate that these shear connectors have suitable shear strength and ductility for application in composite frame structures. The shear strengths obtained using D13 and D16 were not significantly different. However, the ductility of the shear connectors with D16 was 45.1% higher than that of the shear connectors with D13.

AB - Shear connectors are used in steel beam-concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of building structures. Thus, this paper proposes stubby Y-type perfobond rib shear connectors, redefining the existing connectors, for composite frames of building structures; these were used to perform push-out tests. These shear connectors have relatively small ribs compared to the conventional Y-type perfobond rib shear connectors. To confirm the shear resistance of these stubby shear connectors, we performed an experiment by using transverse rebars D13 and D16. The results indicate that these shear connectors have suitable shear strength and ductility for application in composite frame structures. The shear strengths obtained using D13 and D16 were not significantly different. However, the ductility of the shear connectors with D16 was 45.1% higher than that of the shear connectors with D13.

UR - http://www.scopus.com/inward/record.url?scp=85034979689&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85034979689&partnerID=8YFLogxK

U2 - 10.3390/ma10111340

DO - 10.3390/ma10111340

M3 - Article

VL - 10

JO - Materials

JF - Materials

SN - 1996-1944

IS - 11

M1 - 1340

ER -