Abstract
PURPOSE: To assess the reproducibility and agreement of anterior chamber measurements between the Pentacam (PTC) and the Anterior segment optical coherence tomography (AOCT) in normal healthy eyes with open angle. METHODS: Prospective cross-sectional comparative case series. A total of 162 eyes of 81 healthy volunteers with normal open angle were included in this study. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Intra-observer variability and inter-methods agreement of both instruments for ACA and ACD were evaluated. RESULTS: Values of temporal and nasal ACA measured by two instruments were similar, and the results of ACD were also not significantly different between modalities (p > 0.01). ACA and ACD measurements by PTC and AOCT showed good intra-observer and inter-method agreements (all > 0.9). CONCLUSIONS: PTC and AOCT are presumed to be very useful for the anterior chamber angle examination. They may provide good images and quantitative data about the angle structures including ACA and ACD.
Original language | English |
---|---|
Pages (from-to) | 242-245 |
Number of pages | 4 |
Journal | Korean journal of ophthalmology : KJO |
Volume | 22 |
Issue number | 4 |
DOIs | |
Publication status | Published - 2008 Jan 1 |
Fingerprint
All Science Journal Classification (ASJC) codes
- Medicine(all)
Cite this
}
Anterior chamber measurements by pentacam and AS-OCT in eyes with normal open angles. / Yi, Jeong Ho; Hong, Samin; Seong, Gong Je; Kang, Sung Yong; Ma, Kyoung Tak; kim, chanyun.
In: Korean journal of ophthalmology : KJO, Vol. 22, No. 4, 01.01.2008, p. 242-245.Research output: Contribution to journal › Article
TY - JOUR
T1 - Anterior chamber measurements by pentacam and AS-OCT in eyes with normal open angles.
AU - Yi, Jeong Ho
AU - Hong, Samin
AU - Seong, Gong Je
AU - Kang, Sung Yong
AU - Ma, Kyoung Tak
AU - kim, chanyun
PY - 2008/1/1
Y1 - 2008/1/1
N2 - PURPOSE: To assess the reproducibility and agreement of anterior chamber measurements between the Pentacam (PTC) and the Anterior segment optical coherence tomography (AOCT) in normal healthy eyes with open angle. METHODS: Prospective cross-sectional comparative case series. A total of 162 eyes of 81 healthy volunteers with normal open angle were included in this study. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Intra-observer variability and inter-methods agreement of both instruments for ACA and ACD were evaluated. RESULTS: Values of temporal and nasal ACA measured by two instruments were similar, and the results of ACD were also not significantly different between modalities (p > 0.01). ACA and ACD measurements by PTC and AOCT showed good intra-observer and inter-method agreements (all > 0.9). CONCLUSIONS: PTC and AOCT are presumed to be very useful for the anterior chamber angle examination. They may provide good images and quantitative data about the angle structures including ACA and ACD.
AB - PURPOSE: To assess the reproducibility and agreement of anterior chamber measurements between the Pentacam (PTC) and the Anterior segment optical coherence tomography (AOCT) in normal healthy eyes with open angle. METHODS: Prospective cross-sectional comparative case series. A total of 162 eyes of 81 healthy volunteers with normal open angle were included in this study. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Intra-observer variability and inter-methods agreement of both instruments for ACA and ACD were evaluated. RESULTS: Values of temporal and nasal ACA measured by two instruments were similar, and the results of ACD were also not significantly different between modalities (p > 0.01). ACA and ACD measurements by PTC and AOCT showed good intra-observer and inter-method agreements (all > 0.9). CONCLUSIONS: PTC and AOCT are presumed to be very useful for the anterior chamber angle examination. They may provide good images and quantitative data about the angle structures including ACA and ACD.
UR - http://www.scopus.com/inward/record.url?scp=60249087717&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=60249087717&partnerID=8YFLogxK
U2 - 10.3341/kjo.2008.22.4.242
DO - 10.3341/kjo.2008.22.4.242
M3 - Article
C2 - 19096241
AN - SCOPUS:60249087717
VL - 22
SP - 242
EP - 245
JO - Korean journal of ophthalmology : KJO
JF - Korean journal of ophthalmology : KJO
SN - 1011-8942
IS - 4
ER -