Anterior segment measurements using Pentacam and Orbscan II 1 to 5 years after refractive surgery

Sun Woong Kim, Hae Jung Sun, Jee Ho Chang, Eung Kweon Kim

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

PURPOSE: To compare anterior segment measurements between Pentacam and Orbscan II after laser surface ablation. METHODS: Corneal thickness, anterior elevation, posterior elevation, and anterior chamber depth more than 1 year after laser refractive surgery were measured using Pentacam and Orbscan II in 51 eyes that underwent laser epithelial keratomileusis (LASEK) and 21 eyes that underwent photorefractive keratectomy (PRK). As controls, the same comparisons were made in 52 unoperated eyes. RESULTS: Mean follow-up was 28.2 months in the LASEK group and 49.9 months in the PRK group. Mean corneal thickness using Pentacam was thicker than that using Orbscan by 10.4 μm in unoperated eyes, 22.6 μm in LASEK eyes, and 11.0 μm in PRK eyes, but the two devices showed good correlation in all groups. Mean anterior elevation was highly correlated between the two devices with 2.1-μm differences in LASEK eyes, but posterior elevation showed no correlation with significant discrepancies. Mean anterior chamber depth was 0.12- to 0.14-μm thicker with Pentacam than with Orbscan, and highly correlated in all groups. CONCLUSIONS: Pentacam and Orbscan showed good correlations in corneal thickness, anterior elevation, and anterior chamber depth despite some differences in mean values. The two devices, however, showed no correlation in posterior elevation measurements, a difference that was greater in the postoperative groups.

Original languageEnglish
Pages (from-to)1091-1097
Number of pages7
JournalJournal of Refractive Surgery
Volume25
Issue number12
DOIs
Publication statusPublished - 2009 Dec 1

Fingerprint

Refractive Surgical Procedures
Photorefractive Keratectomy
Anterior Chamber
Lasers
Laser Therapy
Equipment and Supplies

All Science Journal Classification (ASJC) codes

  • Surgery
  • Ophthalmology

Cite this

Kim, Sun Woong ; Sun, Hae Jung ; Chang, Jee Ho ; Kim, Eung Kweon. / Anterior segment measurements using Pentacam and Orbscan II 1 to 5 years after refractive surgery. In: Journal of Refractive Surgery. 2009 ; Vol. 25, No. 12. pp. 1091-1097.
@article{d58a376c66fd4b3d9106d2b82b5594ab,
title = "Anterior segment measurements using Pentacam and Orbscan II 1 to 5 years after refractive surgery",
abstract = "PURPOSE: To compare anterior segment measurements between Pentacam and Orbscan II after laser surface ablation. METHODS: Corneal thickness, anterior elevation, posterior elevation, and anterior chamber depth more than 1 year after laser refractive surgery were measured using Pentacam and Orbscan II in 51 eyes that underwent laser epithelial keratomileusis (LASEK) and 21 eyes that underwent photorefractive keratectomy (PRK). As controls, the same comparisons were made in 52 unoperated eyes. RESULTS: Mean follow-up was 28.2 months in the LASEK group and 49.9 months in the PRK group. Mean corneal thickness using Pentacam was thicker than that using Orbscan by 10.4 μm in unoperated eyes, 22.6 μm in LASEK eyes, and 11.0 μm in PRK eyes, but the two devices showed good correlation in all groups. Mean anterior elevation was highly correlated between the two devices with 2.1-μm differences in LASEK eyes, but posterior elevation showed no correlation with significant discrepancies. Mean anterior chamber depth was 0.12- to 0.14-μm thicker with Pentacam than with Orbscan, and highly correlated in all groups. CONCLUSIONS: Pentacam and Orbscan showed good correlations in corneal thickness, anterior elevation, and anterior chamber depth despite some differences in mean values. The two devices, however, showed no correlation in posterior elevation measurements, a difference that was greater in the postoperative groups.",
author = "Kim, {Sun Woong} and Sun, {Hae Jung} and Chang, {Jee Ho} and Kim, {Eung Kweon}",
year = "2009",
month = "12",
day = "1",
doi = "10.3928/1081597X-20091117-08",
language = "English",
volume = "25",
pages = "1091--1097",
journal = "Journal of Refractive Surgery",
issn = "1081-597X",
publisher = "Slack Incorporated",
number = "12",

}

Anterior segment measurements using Pentacam and Orbscan II 1 to 5 years after refractive surgery. / Kim, Sun Woong; Sun, Hae Jung; Chang, Jee Ho; Kim, Eung Kweon.

In: Journal of Refractive Surgery, Vol. 25, No. 12, 01.12.2009, p. 1091-1097.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Anterior segment measurements using Pentacam and Orbscan II 1 to 5 years after refractive surgery

AU - Kim, Sun Woong

AU - Sun, Hae Jung

AU - Chang, Jee Ho

AU - Kim, Eung Kweon

PY - 2009/12/1

Y1 - 2009/12/1

N2 - PURPOSE: To compare anterior segment measurements between Pentacam and Orbscan II after laser surface ablation. METHODS: Corneal thickness, anterior elevation, posterior elevation, and anterior chamber depth more than 1 year after laser refractive surgery were measured using Pentacam and Orbscan II in 51 eyes that underwent laser epithelial keratomileusis (LASEK) and 21 eyes that underwent photorefractive keratectomy (PRK). As controls, the same comparisons were made in 52 unoperated eyes. RESULTS: Mean follow-up was 28.2 months in the LASEK group and 49.9 months in the PRK group. Mean corneal thickness using Pentacam was thicker than that using Orbscan by 10.4 μm in unoperated eyes, 22.6 μm in LASEK eyes, and 11.0 μm in PRK eyes, but the two devices showed good correlation in all groups. Mean anterior elevation was highly correlated between the two devices with 2.1-μm differences in LASEK eyes, but posterior elevation showed no correlation with significant discrepancies. Mean anterior chamber depth was 0.12- to 0.14-μm thicker with Pentacam than with Orbscan, and highly correlated in all groups. CONCLUSIONS: Pentacam and Orbscan showed good correlations in corneal thickness, anterior elevation, and anterior chamber depth despite some differences in mean values. The two devices, however, showed no correlation in posterior elevation measurements, a difference that was greater in the postoperative groups.

AB - PURPOSE: To compare anterior segment measurements between Pentacam and Orbscan II after laser surface ablation. METHODS: Corneal thickness, anterior elevation, posterior elevation, and anterior chamber depth more than 1 year after laser refractive surgery were measured using Pentacam and Orbscan II in 51 eyes that underwent laser epithelial keratomileusis (LASEK) and 21 eyes that underwent photorefractive keratectomy (PRK). As controls, the same comparisons were made in 52 unoperated eyes. RESULTS: Mean follow-up was 28.2 months in the LASEK group and 49.9 months in the PRK group. Mean corneal thickness using Pentacam was thicker than that using Orbscan by 10.4 μm in unoperated eyes, 22.6 μm in LASEK eyes, and 11.0 μm in PRK eyes, but the two devices showed good correlation in all groups. Mean anterior elevation was highly correlated between the two devices with 2.1-μm differences in LASEK eyes, but posterior elevation showed no correlation with significant discrepancies. Mean anterior chamber depth was 0.12- to 0.14-μm thicker with Pentacam than with Orbscan, and highly correlated in all groups. CONCLUSIONS: Pentacam and Orbscan showed good correlations in corneal thickness, anterior elevation, and anterior chamber depth despite some differences in mean values. The two devices, however, showed no correlation in posterior elevation measurements, a difference that was greater in the postoperative groups.

UR - http://www.scopus.com/inward/record.url?scp=74049105691&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=74049105691&partnerID=8YFLogxK

U2 - 10.3928/1081597X-20091117-08

DO - 10.3928/1081597X-20091117-08

M3 - Article

C2 - 20000290

AN - SCOPUS:74049105691

VL - 25

SP - 1091

EP - 1097

JO - Journal of Refractive Surgery

JF - Journal of Refractive Surgery

SN - 1081-597X

IS - 12

ER -