Applications of joint time-frequency domain reflectometry for health assessment of cable insulation integrity in nuclear power plants

David Coats, Jingjiang Wang, Yong June Shin, Roger A. Dougal, Thomas Koshy

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Defective cables in the electric power systems of nuclear power plants can cause failure of essential components in control and instrumentation or power distribution subsystems, resulting in potential safety concerns. Due to this problem, a nondestructive and non-intrusive condition assessment technique is highly desirable to evaluate cable status and to predict the remaining useful life of a cable. The capability of joint time-frequency domain reflectometry (JTFDR) as such a condition assessment technique is studied in this paper. The health status of four popular insulation types utilized in nuclear power plants for control and distribution is monitored using JTFDR in thermal accelerated aging test including: Cross-linked polyethylene (XLPE), tree retardant cross-linked polyethylene (TR-XLPE), ethylene propylene rubber (EPR), and silicone rubber (SIR). The experimental results show that JTFDR can successfully monitor the aging process of all four insulation types. Further, the results from JTFDR are compared with the results from Elongation-at-Break (EAB). These results show that JTFDR technique is comparable with EAB, in some cases providing more linear characteristics with respect to aging time, and has great potential as a non-destructive and non-intrusive condition assessment technique.

Original languageEnglish
Title of host publication7th International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies 2010, NPIC and HMIT 2010
Pages2032-2038
Number of pages7
Volume3
Publication statusPublished - 2010 Dec 1
Event7th International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies 2010, NPIC and HMIT 2010 - Las Vegas, NV, United States
Duration: 2010 Nov 72010 Nov 11

Other

Other7th International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies 2010, NPIC and HMIT 2010
CountryUnited States
CityLas Vegas, NV
Period10/11/710/11/11

Fingerprint

Nuclear power plants
Insulation
Cables
Health
Polyethylenes
Elongation
Rubber
Aging of materials
Thermal aging
Electric power systems
Silicones
Propylene
Ethylene

All Science Journal Classification (ASJC) codes

  • Human-Computer Interaction
  • Nuclear Energy and Engineering
  • Control and Systems Engineering

Cite this

Coats, D., Wang, J., Shin, Y. J., Dougal, R. A., & Koshy, T. (2010). Applications of joint time-frequency domain reflectometry for health assessment of cable insulation integrity in nuclear power plants. In 7th International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies 2010, NPIC and HMIT 2010 (Vol. 3, pp. 2032-2038)
Coats, David ; Wang, Jingjiang ; Shin, Yong June ; Dougal, Roger A. ; Koshy, Thomas. / Applications of joint time-frequency domain reflectometry for health assessment of cable insulation integrity in nuclear power plants. 7th International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies 2010, NPIC and HMIT 2010. Vol. 3 2010. pp. 2032-2038
@inproceedings{939b730d3e27487c9fa9962f15bb1fcd,
title = "Applications of joint time-frequency domain reflectometry for health assessment of cable insulation integrity in nuclear power plants",
abstract = "Defective cables in the electric power systems of nuclear power plants can cause failure of essential components in control and instrumentation or power distribution subsystems, resulting in potential safety concerns. Due to this problem, a nondestructive and non-intrusive condition assessment technique is highly desirable to evaluate cable status and to predict the remaining useful life of a cable. The capability of joint time-frequency domain reflectometry (JTFDR) as such a condition assessment technique is studied in this paper. The health status of four popular insulation types utilized in nuclear power plants for control and distribution is monitored using JTFDR in thermal accelerated aging test including: Cross-linked polyethylene (XLPE), tree retardant cross-linked polyethylene (TR-XLPE), ethylene propylene rubber (EPR), and silicone rubber (SIR). The experimental results show that JTFDR can successfully monitor the aging process of all four insulation types. Further, the results from JTFDR are compared with the results from Elongation-at-Break (EAB). These results show that JTFDR technique is comparable with EAB, in some cases providing more linear characteristics with respect to aging time, and has great potential as a non-destructive and non-intrusive condition assessment technique.",
author = "David Coats and Jingjiang Wang and Shin, {Yong June} and Dougal, {Roger A.} and Thomas Koshy",
year = "2010",
month = "12",
day = "1",
language = "English",
isbn = "9781617822667",
volume = "3",
pages = "2032--2038",
booktitle = "7th International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies 2010, NPIC and HMIT 2010",

}

Coats, D, Wang, J, Shin, YJ, Dougal, RA & Koshy, T 2010, Applications of joint time-frequency domain reflectometry for health assessment of cable insulation integrity in nuclear power plants. in 7th International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies 2010, NPIC and HMIT 2010. vol. 3, pp. 2032-2038, 7th International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies 2010, NPIC and HMIT 2010, Las Vegas, NV, United States, 10/11/7.

Applications of joint time-frequency domain reflectometry for health assessment of cable insulation integrity in nuclear power plants. / Coats, David; Wang, Jingjiang; Shin, Yong June; Dougal, Roger A.; Koshy, Thomas.

7th International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies 2010, NPIC and HMIT 2010. Vol. 3 2010. p. 2032-2038.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Applications of joint time-frequency domain reflectometry for health assessment of cable insulation integrity in nuclear power plants

AU - Coats, David

AU - Wang, Jingjiang

AU - Shin, Yong June

AU - Dougal, Roger A.

AU - Koshy, Thomas

PY - 2010/12/1

Y1 - 2010/12/1

N2 - Defective cables in the electric power systems of nuclear power plants can cause failure of essential components in control and instrumentation or power distribution subsystems, resulting in potential safety concerns. Due to this problem, a nondestructive and non-intrusive condition assessment technique is highly desirable to evaluate cable status and to predict the remaining useful life of a cable. The capability of joint time-frequency domain reflectometry (JTFDR) as such a condition assessment technique is studied in this paper. The health status of four popular insulation types utilized in nuclear power plants for control and distribution is monitored using JTFDR in thermal accelerated aging test including: Cross-linked polyethylene (XLPE), tree retardant cross-linked polyethylene (TR-XLPE), ethylene propylene rubber (EPR), and silicone rubber (SIR). The experimental results show that JTFDR can successfully monitor the aging process of all four insulation types. Further, the results from JTFDR are compared with the results from Elongation-at-Break (EAB). These results show that JTFDR technique is comparable with EAB, in some cases providing more linear characteristics with respect to aging time, and has great potential as a non-destructive and non-intrusive condition assessment technique.

AB - Defective cables in the electric power systems of nuclear power plants can cause failure of essential components in control and instrumentation or power distribution subsystems, resulting in potential safety concerns. Due to this problem, a nondestructive and non-intrusive condition assessment technique is highly desirable to evaluate cable status and to predict the remaining useful life of a cable. The capability of joint time-frequency domain reflectometry (JTFDR) as such a condition assessment technique is studied in this paper. The health status of four popular insulation types utilized in nuclear power plants for control and distribution is monitored using JTFDR in thermal accelerated aging test including: Cross-linked polyethylene (XLPE), tree retardant cross-linked polyethylene (TR-XLPE), ethylene propylene rubber (EPR), and silicone rubber (SIR). The experimental results show that JTFDR can successfully monitor the aging process of all four insulation types. Further, the results from JTFDR are compared with the results from Elongation-at-Break (EAB). These results show that JTFDR technique is comparable with EAB, in some cases providing more linear characteristics with respect to aging time, and has great potential as a non-destructive and non-intrusive condition assessment technique.

UR - http://www.scopus.com/inward/record.url?scp=79958263330&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79958263330&partnerID=8YFLogxK

M3 - Conference contribution

SN - 9781617822667

VL - 3

SP - 2032

EP - 2038

BT - 7th International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies 2010, NPIC and HMIT 2010

ER -

Coats D, Wang J, Shin YJ, Dougal RA, Koshy T. Applications of joint time-frequency domain reflectometry for health assessment of cable insulation integrity in nuclear power plants. In 7th International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies 2010, NPIC and HMIT 2010. Vol. 3. 2010. p. 2032-2038