Biosensors for label free detection based on RF and MEMS technology

Y. I. Kim, T. S. Park, J. H. Kang, M. C. Lee, J. T. Kim, J. H. Park, Hong Koo Baik

Research output: Contribution to journalArticle

36 Citations (Scopus)

Abstract

A bio-detection method and devices based on RF electric signals and MEMS are proposed and demonstrated by a label free method. We have fabricated a transmission line, an inductive device, and a capacitive device with silicon-based MEMS technology. Main issues are fabrication of devices by MEMS technology, surface modification from hydrophobic to hydrophilic of a benzocyclobutene (BCB) layer by plasma radiation and RF signal measurement before and after bio-processing. The devices made by MEMS technology consist of a BCB polymer and Cu metal patterns on a silicon substrate. Glucose oxidase (GOx) and poly dimethyldiallyl ammonium chloride (PDAC) are used as a biomolecule target and probe. The measured output of power loss is 0.8 dB at 1.9 GHz, and its value is pretty distinguishable from the noise level. From the above-mentioned results, it is clear that the proposed RF method and designs are very effective and powerful as a label free detection system.

Original languageEnglish
Pages (from-to)592-599
Number of pages8
JournalSensors and Actuators, B: Chemical
Volume119
Issue number2
DOIs
Publication statusPublished - 2006 Dec 7

Fingerprint

bioinstrumentation
Biosensors
microelectromechanical systems
MEMS
Labels
Silicon
bioprocessing
Glucose Oxidase
Glucose oxidase
Biomolecules
plasma radiation
signal measurement
ammonium chlorides
oxidase
power loss
Surface treatment
silicon
Electric lines
Polymers
glucose

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Instrumentation
  • Condensed Matter Physics
  • Surfaces, Coatings and Films
  • Metals and Alloys
  • Electrical and Electronic Engineering
  • Materials Chemistry

Cite this

Kim, Y. I. ; Park, T. S. ; Kang, J. H. ; Lee, M. C. ; Kim, J. T. ; Park, J. H. ; Baik, Hong Koo. / Biosensors for label free detection based on RF and MEMS technology. In: Sensors and Actuators, B: Chemical. 2006 ; Vol. 119, No. 2. pp. 592-599.
@article{bf645cafa9544a0eadbb2cfbfac3bd8e,
title = "Biosensors for label free detection based on RF and MEMS technology",
abstract = "A bio-detection method and devices based on RF electric signals and MEMS are proposed and demonstrated by a label free method. We have fabricated a transmission line, an inductive device, and a capacitive device with silicon-based MEMS technology. Main issues are fabrication of devices by MEMS technology, surface modification from hydrophobic to hydrophilic of a benzocyclobutene (BCB) layer by plasma radiation and RF signal measurement before and after bio-processing. The devices made by MEMS technology consist of a BCB polymer and Cu metal patterns on a silicon substrate. Glucose oxidase (GOx) and poly dimethyldiallyl ammonium chloride (PDAC) are used as a biomolecule target and probe. The measured output of power loss is 0.8 dB at 1.9 GHz, and its value is pretty distinguishable from the noise level. From the above-mentioned results, it is clear that the proposed RF method and designs are very effective and powerful as a label free detection system.",
author = "Kim, {Y. I.} and Park, {T. S.} and Kang, {J. H.} and Lee, {M. C.} and Kim, {J. T.} and Park, {J. H.} and Baik, {Hong Koo}",
year = "2006",
month = "12",
day = "7",
doi = "10.1016/j.snb.2006.01.015",
language = "English",
volume = "119",
pages = "592--599",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",
number = "2",

}

Biosensors for label free detection based on RF and MEMS technology. / Kim, Y. I.; Park, T. S.; Kang, J. H.; Lee, M. C.; Kim, J. T.; Park, J. H.; Baik, Hong Koo.

In: Sensors and Actuators, B: Chemical, Vol. 119, No. 2, 07.12.2006, p. 592-599.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Biosensors for label free detection based on RF and MEMS technology

AU - Kim, Y. I.

AU - Park, T. S.

AU - Kang, J. H.

AU - Lee, M. C.

AU - Kim, J. T.

AU - Park, J. H.

AU - Baik, Hong Koo

PY - 2006/12/7

Y1 - 2006/12/7

N2 - A bio-detection method and devices based on RF electric signals and MEMS are proposed and demonstrated by a label free method. We have fabricated a transmission line, an inductive device, and a capacitive device with silicon-based MEMS technology. Main issues are fabrication of devices by MEMS technology, surface modification from hydrophobic to hydrophilic of a benzocyclobutene (BCB) layer by plasma radiation and RF signal measurement before and after bio-processing. The devices made by MEMS technology consist of a BCB polymer and Cu metal patterns on a silicon substrate. Glucose oxidase (GOx) and poly dimethyldiallyl ammonium chloride (PDAC) are used as a biomolecule target and probe. The measured output of power loss is 0.8 dB at 1.9 GHz, and its value is pretty distinguishable from the noise level. From the above-mentioned results, it is clear that the proposed RF method and designs are very effective and powerful as a label free detection system.

AB - A bio-detection method and devices based on RF electric signals and MEMS are proposed and demonstrated by a label free method. We have fabricated a transmission line, an inductive device, and a capacitive device with silicon-based MEMS technology. Main issues are fabrication of devices by MEMS technology, surface modification from hydrophobic to hydrophilic of a benzocyclobutene (BCB) layer by plasma radiation and RF signal measurement before and after bio-processing. The devices made by MEMS technology consist of a BCB polymer and Cu metal patterns on a silicon substrate. Glucose oxidase (GOx) and poly dimethyldiallyl ammonium chloride (PDAC) are used as a biomolecule target and probe. The measured output of power loss is 0.8 dB at 1.9 GHz, and its value is pretty distinguishable from the noise level. From the above-mentioned results, it is clear that the proposed RF method and designs are very effective and powerful as a label free detection system.

UR - http://www.scopus.com/inward/record.url?scp=33748743525&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33748743525&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2006.01.015

DO - 10.1016/j.snb.2006.01.015

M3 - Article

AN - SCOPUS:33748743525

VL - 119

SP - 592

EP - 599

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

IS - 2

ER -