Biotribological investigation of a multi-tube foot for traction generation in a medical microrobot

Y. T. Kim, D. E. Kim

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

In recent years, efforts to develop microrobots for medical applications have been expanding. One of the key design issues in such microrobots is to attain adequate frictional interaction between the robotic foot and the organ tissue. In particular, it is important to generate the necessary frictional force without damaging the tissue. In this work, a design for the robotic foot was proposed on the basis of the frictional behaviour of a tube structure. Fundamental experiments were initially performed to understand the biotribological behaviour of the tube and rod structures. The design was then modified to a multi-tube structure to achieve adequate frictional behaviour. Biotribological investigation of a multi-tube foot in contact with a small intestine specimen of a pig was conducted using a pin-on-reciprocator type biotribotester. It was found that there is an optimum number and arrangement of the tubes for generating high frictional force. Experimental results showed that a nine-tube foot had the highest initial friction coefficient of about 1.5. The major frictional mechanism was determined to be interlocking between the tubes and the surface structures of the intestine specimen. The results of this work will aid the optimum design of frictional surface for medical microrobots and other biological devices.

Original languageEnglish
Pages (from-to)677-686
Number of pages10
JournalProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Volume223
Issue number6
DOIs
Publication statusPublished - 2009 Sep 28

Fingerprint

Robotics
Tissue
Medical applications
Surface structure
Friction
Experiments
Optimum design

All Science Journal Classification (ASJC) codes

  • Mechanical Engineering

Cite this

@article{a09601c5b9af447892bfd4a9506837b0,
title = "Biotribological investigation of a multi-tube foot for traction generation in a medical microrobot",
abstract = "In recent years, efforts to develop microrobots for medical applications have been expanding. One of the key design issues in such microrobots is to attain adequate frictional interaction between the robotic foot and the organ tissue. In particular, it is important to generate the necessary frictional force without damaging the tissue. In this work, a design for the robotic foot was proposed on the basis of the frictional behaviour of a tube structure. Fundamental experiments were initially performed to understand the biotribological behaviour of the tube and rod structures. The design was then modified to a multi-tube structure to achieve adequate frictional behaviour. Biotribological investigation of a multi-tube foot in contact with a small intestine specimen of a pig was conducted using a pin-on-reciprocator type biotribotester. It was found that there is an optimum number and arrangement of the tubes for generating high frictional force. Experimental results showed that a nine-tube foot had the highest initial friction coefficient of about 1.5. The major frictional mechanism was determined to be interlocking between the tubes and the surface structures of the intestine specimen. The results of this work will aid the optimum design of frictional surface for medical microrobots and other biological devices.",
author = "Kim, {Y. T.} and Kim, {D. E.}",
year = "2009",
month = "9",
day = "28",
doi = "10.1243/09544119JEIM595",
language = "English",
volume = "223",
pages = "677--686",
journal = "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine",
issn = "0954-4119",
publisher = "SAGE Publications Ltd",
number = "6",

}

TY - JOUR

T1 - Biotribological investigation of a multi-tube foot for traction generation in a medical microrobot

AU - Kim, Y. T.

AU - Kim, D. E.

PY - 2009/9/28

Y1 - 2009/9/28

N2 - In recent years, efforts to develop microrobots for medical applications have been expanding. One of the key design issues in such microrobots is to attain adequate frictional interaction between the robotic foot and the organ tissue. In particular, it is important to generate the necessary frictional force without damaging the tissue. In this work, a design for the robotic foot was proposed on the basis of the frictional behaviour of a tube structure. Fundamental experiments were initially performed to understand the biotribological behaviour of the tube and rod structures. The design was then modified to a multi-tube structure to achieve adequate frictional behaviour. Biotribological investigation of a multi-tube foot in contact with a small intestine specimen of a pig was conducted using a pin-on-reciprocator type biotribotester. It was found that there is an optimum number and arrangement of the tubes for generating high frictional force. Experimental results showed that a nine-tube foot had the highest initial friction coefficient of about 1.5. The major frictional mechanism was determined to be interlocking between the tubes and the surface structures of the intestine specimen. The results of this work will aid the optimum design of frictional surface for medical microrobots and other biological devices.

AB - In recent years, efforts to develop microrobots for medical applications have been expanding. One of the key design issues in such microrobots is to attain adequate frictional interaction between the robotic foot and the organ tissue. In particular, it is important to generate the necessary frictional force without damaging the tissue. In this work, a design for the robotic foot was proposed on the basis of the frictional behaviour of a tube structure. Fundamental experiments were initially performed to understand the biotribological behaviour of the tube and rod structures. The design was then modified to a multi-tube structure to achieve adequate frictional behaviour. Biotribological investigation of a multi-tube foot in contact with a small intestine specimen of a pig was conducted using a pin-on-reciprocator type biotribotester. It was found that there is an optimum number and arrangement of the tubes for generating high frictional force. Experimental results showed that a nine-tube foot had the highest initial friction coefficient of about 1.5. The major frictional mechanism was determined to be interlocking between the tubes and the surface structures of the intestine specimen. The results of this work will aid the optimum design of frictional surface for medical microrobots and other biological devices.

UR - http://www.scopus.com/inward/record.url?scp=70349316597&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70349316597&partnerID=8YFLogxK

U2 - 10.1243/09544119JEIM595

DO - 10.1243/09544119JEIM595

M3 - Article

C2 - 19743634

AN - SCOPUS:70349316597

VL - 223

SP - 677

EP - 686

JO - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

JF - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

SN - 0954-4119

IS - 6

ER -