Bone apposition on implants coated with calcium phosphate by ion beam assisted deposition in oversized drilled sockets: A histologic and histometric analysis in dogs

Min Soo Kim, Ui-Won Jung, Sungtae Kim, Jung Seok Lee, In Seop Lee, Seongho Choi

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Purpose: The purpose of this study was to evaluate the osseointegration of calcium phosphate (CaP)-coated implants by ion beam assisted deposition with a lack of primary stability. Methods: A total of 20 CaP-coated implants were bilaterally placed in the mandible of five dogs. In the rotational implant group, the implants were inserted in oversized drilled sockets without mechanical engagement, while the conventional surgical protocol was followed in the control group. Each group was allowed to heal for 4 and 8 weeks. The bone-to-implant contact (BIC, %) was measured by a histometric analysis. Results: All of the implants were well-maintained and healing was uneventful. In the histologic observation, all of the implants tested were successfully osseointegrated with a high level of BIC at both observation intervals. There was no significant difference in BIC among any of the groups. Conclusions: Within the limitation of this study, successful osseointegration of CaP-coated implants could be achieved in unfavorable conditions without primary stability.

Original languageEnglish
Pages (from-to)18-23
Number of pages6
JournalJournal of Periodontal and Implant Science
Volume43
Issue number1
DOIs
Publication statusPublished - 2013 Feb 1

Fingerprint

imidazole mustard
Osseointegration
Dogs
Ions
Bone and Bones
Observation
Mandible
Control Groups
calcium phosphate

All Science Journal Classification (ASJC) codes

  • Oral Surgery
  • Periodontics

Cite this

@article{5a1988e7eb7145dc8aca0c2fb398b08d,
title = "Bone apposition on implants coated with calcium phosphate by ion beam assisted deposition in oversized drilled sockets: A histologic and histometric analysis in dogs",
abstract = "Purpose: The purpose of this study was to evaluate the osseointegration of calcium phosphate (CaP)-coated implants by ion beam assisted deposition with a lack of primary stability. Methods: A total of 20 CaP-coated implants were bilaterally placed in the mandible of five dogs. In the rotational implant group, the implants were inserted in oversized drilled sockets without mechanical engagement, while the conventional surgical protocol was followed in the control group. Each group was allowed to heal for 4 and 8 weeks. The bone-to-implant contact (BIC, {\%}) was measured by a histometric analysis. Results: All of the implants were well-maintained and healing was uneventful. In the histologic observation, all of the implants tested were successfully osseointegrated with a high level of BIC at both observation intervals. There was no significant difference in BIC among any of the groups. Conclusions: Within the limitation of this study, successful osseointegration of CaP-coated implants could be achieved in unfavorable conditions without primary stability.",
author = "Kim, {Min Soo} and Ui-Won Jung and Sungtae Kim and Lee, {Jung Seok} and Lee, {In Seop} and Seongho Choi",
year = "2013",
month = "2",
day = "1",
doi = "10.5051/jpis.2013.43.1.18",
language = "English",
volume = "43",
pages = "18--23",
journal = "Journal of Periodontal and Implant Science",
issn = "2093-2278",
publisher = "Korean Academy of Periodontology",
number = "1",

}

TY - JOUR

T1 - Bone apposition on implants coated with calcium phosphate by ion beam assisted deposition in oversized drilled sockets

T2 - A histologic and histometric analysis in dogs

AU - Kim, Min Soo

AU - Jung, Ui-Won

AU - Kim, Sungtae

AU - Lee, Jung Seok

AU - Lee, In Seop

AU - Choi, Seongho

PY - 2013/2/1

Y1 - 2013/2/1

N2 - Purpose: The purpose of this study was to evaluate the osseointegration of calcium phosphate (CaP)-coated implants by ion beam assisted deposition with a lack of primary stability. Methods: A total of 20 CaP-coated implants were bilaterally placed in the mandible of five dogs. In the rotational implant group, the implants were inserted in oversized drilled sockets without mechanical engagement, while the conventional surgical protocol was followed in the control group. Each group was allowed to heal for 4 and 8 weeks. The bone-to-implant contact (BIC, %) was measured by a histometric analysis. Results: All of the implants were well-maintained and healing was uneventful. In the histologic observation, all of the implants tested were successfully osseointegrated with a high level of BIC at both observation intervals. There was no significant difference in BIC among any of the groups. Conclusions: Within the limitation of this study, successful osseointegration of CaP-coated implants could be achieved in unfavorable conditions without primary stability.

AB - Purpose: The purpose of this study was to evaluate the osseointegration of calcium phosphate (CaP)-coated implants by ion beam assisted deposition with a lack of primary stability. Methods: A total of 20 CaP-coated implants were bilaterally placed in the mandible of five dogs. In the rotational implant group, the implants were inserted in oversized drilled sockets without mechanical engagement, while the conventional surgical protocol was followed in the control group. Each group was allowed to heal for 4 and 8 weeks. The bone-to-implant contact (BIC, %) was measured by a histometric analysis. Results: All of the implants were well-maintained and healing was uneventful. In the histologic observation, all of the implants tested were successfully osseointegrated with a high level of BIC at both observation intervals. There was no significant difference in BIC among any of the groups. Conclusions: Within the limitation of this study, successful osseointegration of CaP-coated implants could be achieved in unfavorable conditions without primary stability.

UR - http://www.scopus.com/inward/record.url?scp=84875893911&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84875893911&partnerID=8YFLogxK

U2 - 10.5051/jpis.2013.43.1.18

DO - 10.5051/jpis.2013.43.1.18

M3 - Article

C2 - 23507657

AN - SCOPUS:84875893911

VL - 43

SP - 18

EP - 23

JO - Journal of Periodontal and Implant Science

JF - Journal of Periodontal and Implant Science

SN - 2093-2278

IS - 1

ER -