TY - JOUR
T1 - Cellulose dimethylphenylcarbamate-bonded carbon-clad zirconia for chiral separation in high performance liquid chromatography
AU - Kwon, Sang Hyun
AU - Okamoto, Yoshio
AU - Yamamoto, Chiyo
AU - Cheong, Wonjo
AU - Moon, Myeonghee
AU - Park, Jung Hag
PY - 2006/12
Y1 - 2006/12
N2 - Porous zirconia particles are very robust material and have received considerable attention as a stationary phase support for HPLC. We prepared cellulose dimethylphenylcarbamate-bonded carbon-clad zirconia (CDMPCCZ) as a chiral stationary phase (CSP) for separation of enantiomers of a set of 14 racemic compounds in normal phase (NP) and reversed-phase (RP) liquid chromatography. Retention and enantioselectivity on CDMPCCZ were compared to those on CDMPC-coated zirconia (CDMPCZ) to see how the change in immobilization method of the chiral selector affects the retention and chiral selectivity. In NPLC, retention was longer and the number of resolved racemates was smaller on CDMPCCZ than on CDMPCZ. However, chiral selectivity factors for some resolved racemates were better on CDMPCCZ than on CDMPCZ. The longer retention on CDMPCCZ is likely due to strong, non-chiral discriminating interactions with the carbon layer on CDMPCZ. In RPLC only two racemates were resolved on CDMPCCZ, but retention times were shorter than, and resolutions were comparable to, those in NPLC, indicating a potential for improving chromatographic performance of the CDMPCCZ column in RPLC with optimized column preparation and separation conditions. 2006
AB - Porous zirconia particles are very robust material and have received considerable attention as a stationary phase support for HPLC. We prepared cellulose dimethylphenylcarbamate-bonded carbon-clad zirconia (CDMPCCZ) as a chiral stationary phase (CSP) for separation of enantiomers of a set of 14 racemic compounds in normal phase (NP) and reversed-phase (RP) liquid chromatography. Retention and enantioselectivity on CDMPCCZ were compared to those on CDMPC-coated zirconia (CDMPCZ) to see how the change in immobilization method of the chiral selector affects the retention and chiral selectivity. In NPLC, retention was longer and the number of resolved racemates was smaller on CDMPCCZ than on CDMPCZ. However, chiral selectivity factors for some resolved racemates were better on CDMPCCZ than on CDMPCZ. The longer retention on CDMPCCZ is likely due to strong, non-chiral discriminating interactions with the carbon layer on CDMPCZ. In RPLC only two racemates were resolved on CDMPCCZ, but retention times were shorter than, and resolutions were comparable to, those in NPLC, indicating a potential for improving chromatographic performance of the CDMPCCZ column in RPLC with optimized column preparation and separation conditions. 2006
UR - http://www.scopus.com/inward/record.url?scp=45249089320&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=45249089320&partnerID=8YFLogxK
U2 - 10.2116/analsci.22.1525
DO - 10.2116/analsci.22.1525
M3 - Article
C2 - 17159310
AN - SCOPUS:45249089320
VL - 22
SP - 1525
EP - 1529
JO - Analytical Sciences
JF - Analytical Sciences
SN - 0910-6340
IS - 12
ER -