TY - JOUR
T1 - Comparative Outcome Analysis of N-Butyl Cyanoacrylate Embolization of the False Lumen Versus Thoracic Endovascular Aortic Repair in Aortic Dissection
AU - Kim, Dong Kyu
AU - Kwon, Joon Ho
AU - Ko, Heung Kyu
AU - Lee, Junhyung
AU - Han, Kichang
AU - Kim, Gyoung Min
AU - Kim, Man Deuk
AU - Won, Jong Yun
AU - Joo, Hyun Chel
AU - Ko, Young Guk
AU - Lee, Do Yun
N1 - Publisher Copyright:
© 2020 SIR
PY - 2021/1
Y1 - 2021/1
N2 - Purpose: To evaluate the feasibility, safety, and effectiveness of N-butyl cyanoacrylate (NBCA) embolization for the treatment of aortic dissection. Materials and Methods: In this single-center retrospective study conducted from February 2003 to June 2019, NBCA embolization of an aortic false lumen was attempted in 12 patients (median age, 59 y; range, 41–68 y) and thoracic endovascular aortic repair (TEVAR) was performed in 53 patients (median age, 59 y; range, 37–70 y) for aortic dissection with one or more indications of persisting pain, malperfusion, rupture or impending rupture, maximal aortic diameter ≥ 55 mm, and/or rapid aortic enlargement. The main exclusion criterion for embolization was the presence of fast blood flow in the aortic false lumen on aortography. The efficacy of NBCA embolization and TEVAR was compared by evaluating technical and clinical outcomes, repeat intervention–free survival (RFS), and overall survival (OS). Results: Technical success was achieved in 11 of the 12 patients treated with NBCA embolization (91.7%), and clinical success was achieved in 9 of these 11 (81.8%). No significant difference was found between embolization and TEVAR in clinical success rates (embolization, 81.8%; TEVAR, 84.9%; P =.409) or procedure-related complications (embolization, 1 patient [8.3%]; TEVAR, 4 patients [7.5%]; P =.701). In addition, embolization showed comparable 5-y RFS (embolization, 82.5% ± 9.3; TEVAR, 85.5% ± 4.8; P =.641) and 5-y OS (embolization, 100%; TEVAR, 95.4% ± 3.2; P =.744) rates to TEVAR. Conclusions: NBCA embolization of the false lumen in aortic dissection seems to be a safe and effective treatment modality for the closure of false lumen in selected patients.
AB - Purpose: To evaluate the feasibility, safety, and effectiveness of N-butyl cyanoacrylate (NBCA) embolization for the treatment of aortic dissection. Materials and Methods: In this single-center retrospective study conducted from February 2003 to June 2019, NBCA embolization of an aortic false lumen was attempted in 12 patients (median age, 59 y; range, 41–68 y) and thoracic endovascular aortic repair (TEVAR) was performed in 53 patients (median age, 59 y; range, 37–70 y) for aortic dissection with one or more indications of persisting pain, malperfusion, rupture or impending rupture, maximal aortic diameter ≥ 55 mm, and/or rapid aortic enlargement. The main exclusion criterion for embolization was the presence of fast blood flow in the aortic false lumen on aortography. The efficacy of NBCA embolization and TEVAR was compared by evaluating technical and clinical outcomes, repeat intervention–free survival (RFS), and overall survival (OS). Results: Technical success was achieved in 11 of the 12 patients treated with NBCA embolization (91.7%), and clinical success was achieved in 9 of these 11 (81.8%). No significant difference was found between embolization and TEVAR in clinical success rates (embolization, 81.8%; TEVAR, 84.9%; P =.409) or procedure-related complications (embolization, 1 patient [8.3%]; TEVAR, 4 patients [7.5%]; P =.701). In addition, embolization showed comparable 5-y RFS (embolization, 82.5% ± 9.3; TEVAR, 85.5% ± 4.8; P =.641) and 5-y OS (embolization, 100%; TEVAR, 95.4% ± 3.2; P =.744) rates to TEVAR. Conclusions: NBCA embolization of the false lumen in aortic dissection seems to be a safe and effective treatment modality for the closure of false lumen in selected patients.
UR - http://www.scopus.com/inward/record.url?scp=85097067542&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85097067542&partnerID=8YFLogxK
U2 - 10.1016/j.jvir.2020.08.037
DO - 10.1016/j.jvir.2020.08.037
M3 - Article
C2 - 33246735
AN - SCOPUS:85097067542
SN - 1051-0443
VL - 32
SP - 39
EP - 48
JO - Journal of Vascular and Interventional Radiology
JF - Journal of Vascular and Interventional Radiology
IS - 1
ER -