Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia

Rae Kim Na, Suk Lee Eun, Je Seong Gong, Yong Kang Sung, Hyun Kim Ji, Hong Samin, Yun Kim Chan

Research output: Contribution to journalArticle

97 Citations (Scopus)

Abstract

Aim: To compare the diagnostic ability to detect glaucomatous changes between peripapillary retinal nerve fibre layer (RNFL) thickness and the macular ganglion cell complex (GCC) in highly myopic patients using Fourier domain optical coherence tomography. Methods: Participants, consecutively enrolled from January 2009 to June 2009, were imaged with RTVue-100 (NHM4 and MM7 scan). The sensitivity and specificity of a colour code less than 5% (red or yellow) for glaucoma diagnosis were calculated. Area under the receiver operator characteristic (AUROC) curves were generated to assess the ability of each parameter to detect glaucomatous changes. Results: 73 normal controls and 77 glaucoma patients were included. Participants were categorised as 105 non-high myopes (spherical equivalent >-6.0 dioptres) and 45 high myopes (Spherical equivalent ≤-6.0 dioptres). The GCC thickness showed a strong correlation with RNFL thickness (correlation coefficient=0.763, p<0.001) in all participants. The sensitivity from superior GCC colour code was significantly higher than that from superior RNFL (p=0.019). The ability to detect glaucomatous changes in the highly myopic group by examining the average GCC thickness (AUROC, GCC; 0.889) was higher than when examining RNFL thickness (AUROC, RNFL; 0.825); however, there was no statistical significance (p=0.442). Conclusions: The ability to diagnose glaucoma with macular GCC thickness was comparable with that with peripapillary RNFL thickness in high-myopia patients. Macular GCC thickness measurements may be a good alternative or a complementary measurement to RNFL thickness assessment in the clinical evaluation of glaucoma in patients with high myopia.

Original languageEnglish
Pages (from-to)1115-1121
Number of pages7
JournalBritish Journal of Ophthalmology
Volume95
Issue number8
DOIs
Publication statusPublished - 2011 Aug 1

Fingerprint

Retinal Ganglion Cells
Myopia
Nerve Fibers
Ganglia
Glaucoma
Color
Optical Coherence Tomography
Sensitivity and Specificity

All Science Journal Classification (ASJC) codes

  • Ophthalmology
  • Sensory Systems
  • Cellular and Molecular Neuroscience

Cite this

Na, Rae Kim ; Eun, Suk Lee ; Gong, Je Seong ; Sung, Yong Kang ; Ji, Hyun Kim ; Samin, Hong ; Chan, Yun Kim. / Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia. In: British Journal of Ophthalmology. 2011 ; Vol. 95, No. 8. pp. 1115-1121.
@article{45707f1dceda490c8fd6067e95bb5b5f,
title = "Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia",
abstract = "Aim: To compare the diagnostic ability to detect glaucomatous changes between peripapillary retinal nerve fibre layer (RNFL) thickness and the macular ganglion cell complex (GCC) in highly myopic patients using Fourier domain optical coherence tomography. Methods: Participants, consecutively enrolled from January 2009 to June 2009, were imaged with RTVue-100 (NHM4 and MM7 scan). The sensitivity and specificity of a colour code less than 5{\%} (red or yellow) for glaucoma diagnosis were calculated. Area under the receiver operator characteristic (AUROC) curves were generated to assess the ability of each parameter to detect glaucomatous changes. Results: 73 normal controls and 77 glaucoma patients were included. Participants were categorised as 105 non-high myopes (spherical equivalent >-6.0 dioptres) and 45 high myopes (Spherical equivalent ≤-6.0 dioptres). The GCC thickness showed a strong correlation with RNFL thickness (correlation coefficient=0.763, p<0.001) in all participants. The sensitivity from superior GCC colour code was significantly higher than that from superior RNFL (p=0.019). The ability to detect glaucomatous changes in the highly myopic group by examining the average GCC thickness (AUROC, GCC; 0.889) was higher than when examining RNFL thickness (AUROC, RNFL; 0.825); however, there was no statistical significance (p=0.442). Conclusions: The ability to diagnose glaucoma with macular GCC thickness was comparable with that with peripapillary RNFL thickness in high-myopia patients. Macular GCC thickness measurements may be a good alternative or a complementary measurement to RNFL thickness assessment in the clinical evaluation of glaucoma in patients with high myopia.",
author = "Na, {Rae Kim} and Eun, {Suk Lee} and Gong, {Je Seong} and Sung, {Yong Kang} and Ji, {Hyun Kim} and Hong Samin and Chan, {Yun Kim}",
year = "2011",
month = "8",
day = "1",
doi = "10.1136/bjo.2010.182493",
language = "English",
volume = "95",
pages = "1115--1121",
journal = "British Journal of Ophthalmology",
issn = "0007-1161",
publisher = "BMJ Publishing Group",
number = "8",

}

Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia. / Na, Rae Kim; Eun, Suk Lee; Gong, Je Seong; Sung, Yong Kang; Ji, Hyun Kim; Samin, Hong; Chan, Yun Kim.

In: British Journal of Ophthalmology, Vol. 95, No. 8, 01.08.2011, p. 1115-1121.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia

AU - Na, Rae Kim

AU - Eun, Suk Lee

AU - Gong, Je Seong

AU - Sung, Yong Kang

AU - Ji, Hyun Kim

AU - Samin, Hong

AU - Chan, Yun Kim

PY - 2011/8/1

Y1 - 2011/8/1

N2 - Aim: To compare the diagnostic ability to detect glaucomatous changes between peripapillary retinal nerve fibre layer (RNFL) thickness and the macular ganglion cell complex (GCC) in highly myopic patients using Fourier domain optical coherence tomography. Methods: Participants, consecutively enrolled from January 2009 to June 2009, were imaged with RTVue-100 (NHM4 and MM7 scan). The sensitivity and specificity of a colour code less than 5% (red or yellow) for glaucoma diagnosis were calculated. Area under the receiver operator characteristic (AUROC) curves were generated to assess the ability of each parameter to detect glaucomatous changes. Results: 73 normal controls and 77 glaucoma patients were included. Participants were categorised as 105 non-high myopes (spherical equivalent >-6.0 dioptres) and 45 high myopes (Spherical equivalent ≤-6.0 dioptres). The GCC thickness showed a strong correlation with RNFL thickness (correlation coefficient=0.763, p<0.001) in all participants. The sensitivity from superior GCC colour code was significantly higher than that from superior RNFL (p=0.019). The ability to detect glaucomatous changes in the highly myopic group by examining the average GCC thickness (AUROC, GCC; 0.889) was higher than when examining RNFL thickness (AUROC, RNFL; 0.825); however, there was no statistical significance (p=0.442). Conclusions: The ability to diagnose glaucoma with macular GCC thickness was comparable with that with peripapillary RNFL thickness in high-myopia patients. Macular GCC thickness measurements may be a good alternative or a complementary measurement to RNFL thickness assessment in the clinical evaluation of glaucoma in patients with high myopia.

AB - Aim: To compare the diagnostic ability to detect glaucomatous changes between peripapillary retinal nerve fibre layer (RNFL) thickness and the macular ganglion cell complex (GCC) in highly myopic patients using Fourier domain optical coherence tomography. Methods: Participants, consecutively enrolled from January 2009 to June 2009, were imaged with RTVue-100 (NHM4 and MM7 scan). The sensitivity and specificity of a colour code less than 5% (red or yellow) for glaucoma diagnosis were calculated. Area under the receiver operator characteristic (AUROC) curves were generated to assess the ability of each parameter to detect glaucomatous changes. Results: 73 normal controls and 77 glaucoma patients were included. Participants were categorised as 105 non-high myopes (spherical equivalent >-6.0 dioptres) and 45 high myopes (Spherical equivalent ≤-6.0 dioptres). The GCC thickness showed a strong correlation with RNFL thickness (correlation coefficient=0.763, p<0.001) in all participants. The sensitivity from superior GCC colour code was significantly higher than that from superior RNFL (p=0.019). The ability to detect glaucomatous changes in the highly myopic group by examining the average GCC thickness (AUROC, GCC; 0.889) was higher than when examining RNFL thickness (AUROC, RNFL; 0.825); however, there was no statistical significance (p=0.442). Conclusions: The ability to diagnose glaucoma with macular GCC thickness was comparable with that with peripapillary RNFL thickness in high-myopia patients. Macular GCC thickness measurements may be a good alternative or a complementary measurement to RNFL thickness assessment in the clinical evaluation of glaucoma in patients with high myopia.

UR - http://www.scopus.com/inward/record.url?scp=79960638234&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79960638234&partnerID=8YFLogxK

U2 - 10.1136/bjo.2010.182493

DO - 10.1136/bjo.2010.182493

M3 - Article

C2 - 20805125

AN - SCOPUS:79960638234

VL - 95

SP - 1115

EP - 1121

JO - British Journal of Ophthalmology

JF - British Journal of Ophthalmology

SN - 0007-1161

IS - 8

ER -