Controlled Space Closure with a Statically Determinate Retraction System

Kwangchul Choy, Eung Kwon Pae, Kyungho Kim, Young Chel Park, Charles J. Burstone

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

We designed a variant of a cantilever spring, the statically determinate retraction system, and studied its mechanical characteristics. This novel system consisted of a single-force cantilever arm made of 0.017 X 0.025-inch titanium molybdenum alloy wire for active retraction and a passive rigid stabilizing unit. Since the active component for space closure is a cantilever, it is simple to measure the force system of the spring with a force gauge (ie, the system is a statically determinate system). A torque tester apparatus was used to examine the property of this retraction spring with a helix at the posterior and a simple bend at the anterior. Both a standard shape and modified shapes of the spring were studied. At full activation, the standard spring delivered 163 g with a load-deflection rate of six g/mm. When the magnitude of the anterior bend of the spring was increased, the horizontal component of the force increased more than the vertical component. In contrast, when the posterior bend of the spring increased, the vertical component of the force increased more than the horizontal component. A clinical case presented here clearly demonstrates the versatility and applicability of the spring.

Original languageEnglish
Pages (from-to)191-198
Number of pages8
JournalAngle Orthodontist
Volume72
Issue number3
Publication statusPublished - 2002 Jun 1

Fingerprint

Torque
titanium molybdenum alloy

All Science Journal Classification (ASJC) codes

  • Orthodontics

Cite this

Choy, K., Pae, E. K., Kim, K., Park, Y. C., & Burstone, C. J. (2002). Controlled Space Closure with a Statically Determinate Retraction System. Angle Orthodontist, 72(3), 191-198.
Choy, Kwangchul ; Pae, Eung Kwon ; Kim, Kyungho ; Park, Young Chel ; Burstone, Charles J. / Controlled Space Closure with a Statically Determinate Retraction System. In: Angle Orthodontist. 2002 ; Vol. 72, No. 3. pp. 191-198.
@article{d59da4f0c6cb473f817d414df59605b0,
title = "Controlled Space Closure with a Statically Determinate Retraction System",
abstract = "We designed a variant of a cantilever spring, the statically determinate retraction system, and studied its mechanical characteristics. This novel system consisted of a single-force cantilever arm made of 0.017 X 0.025-inch titanium molybdenum alloy wire for active retraction and a passive rigid stabilizing unit. Since the active component for space closure is a cantilever, it is simple to measure the force system of the spring with a force gauge (ie, the system is a statically determinate system). A torque tester apparatus was used to examine the property of this retraction spring with a helix at the posterior and a simple bend at the anterior. Both a standard shape and modified shapes of the spring were studied. At full activation, the standard spring delivered 163 g with a load-deflection rate of six g/mm. When the magnitude of the anterior bend of the spring was increased, the horizontal component of the force increased more than the vertical component. In contrast, when the posterior bend of the spring increased, the vertical component of the force increased more than the horizontal component. A clinical case presented here clearly demonstrates the versatility and applicability of the spring.",
author = "Kwangchul Choy and Pae, {Eung Kwon} and Kyungho Kim and Park, {Young Chel} and Burstone, {Charles J.}",
year = "2002",
month = "6",
day = "1",
language = "English",
volume = "72",
pages = "191--198",
journal = "Angle Orthodontist",
issn = "0003-3219",
publisher = "E H Angle Orthodontists Research & Education Foundation, Inc.",
number = "3",

}

Choy, K, Pae, EK, Kim, K, Park, YC & Burstone, CJ 2002, 'Controlled Space Closure with a Statically Determinate Retraction System', Angle Orthodontist, vol. 72, no. 3, pp. 191-198.

Controlled Space Closure with a Statically Determinate Retraction System. / Choy, Kwangchul; Pae, Eung Kwon; Kim, Kyungho; Park, Young Chel; Burstone, Charles J.

In: Angle Orthodontist, Vol. 72, No. 3, 01.06.2002, p. 191-198.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Controlled Space Closure with a Statically Determinate Retraction System

AU - Choy, Kwangchul

AU - Pae, Eung Kwon

AU - Kim, Kyungho

AU - Park, Young Chel

AU - Burstone, Charles J.

PY - 2002/6/1

Y1 - 2002/6/1

N2 - We designed a variant of a cantilever spring, the statically determinate retraction system, and studied its mechanical characteristics. This novel system consisted of a single-force cantilever arm made of 0.017 X 0.025-inch titanium molybdenum alloy wire for active retraction and a passive rigid stabilizing unit. Since the active component for space closure is a cantilever, it is simple to measure the force system of the spring with a force gauge (ie, the system is a statically determinate system). A torque tester apparatus was used to examine the property of this retraction spring with a helix at the posterior and a simple bend at the anterior. Both a standard shape and modified shapes of the spring were studied. At full activation, the standard spring delivered 163 g with a load-deflection rate of six g/mm. When the magnitude of the anterior bend of the spring was increased, the horizontal component of the force increased more than the vertical component. In contrast, when the posterior bend of the spring increased, the vertical component of the force increased more than the horizontal component. A clinical case presented here clearly demonstrates the versatility and applicability of the spring.

AB - We designed a variant of a cantilever spring, the statically determinate retraction system, and studied its mechanical characteristics. This novel system consisted of a single-force cantilever arm made of 0.017 X 0.025-inch titanium molybdenum alloy wire for active retraction and a passive rigid stabilizing unit. Since the active component for space closure is a cantilever, it is simple to measure the force system of the spring with a force gauge (ie, the system is a statically determinate system). A torque tester apparatus was used to examine the property of this retraction spring with a helix at the posterior and a simple bend at the anterior. Both a standard shape and modified shapes of the spring were studied. At full activation, the standard spring delivered 163 g with a load-deflection rate of six g/mm. When the magnitude of the anterior bend of the spring was increased, the horizontal component of the force increased more than the vertical component. In contrast, when the posterior bend of the spring increased, the vertical component of the force increased more than the horizontal component. A clinical case presented here clearly demonstrates the versatility and applicability of the spring.

UR - http://www.scopus.com/inward/record.url?scp=0036595262&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036595262&partnerID=8YFLogxK

M3 - Article

VL - 72

SP - 191

EP - 198

JO - Angle Orthodontist

JF - Angle Orthodontist

SN - 0003-3219

IS - 3

ER -

Choy K, Pae EK, Kim K, Park YC, Burstone CJ. Controlled Space Closure with a Statically Determinate Retraction System. Angle Orthodontist. 2002 Jun 1;72(3):191-198.