Corneal astigmatism analysis for toric intraocular lens implantation: Precise measurements for perfect correction

Research output: Contribution to journalReview article

12 Citations (Scopus)

Abstract

Purpose of review Corneal astigmatism is a common refractive error observed in a significant percentage of cataract patients. Accurate measurements of the preexisting corneal astigmatism are essential in order to achieve the desired refractive outcome after toric intraocular lens (IOL) implantation. This article presents a comprehensive review of recent published literatures on methods for measuring preoperative corneal astigmatism for toric IOL implantation.

Recent findings A variety of instruments has been introduced and used to measure the magnitude and meridian of corneal astigmatism during preoperative assessments of cataract patients. Instruments that consider both the anterior and posterior corneal surfaces as critical factors for measuring total corneal astigmatism are expected to provide better accuracy. Although these instruments facilitate improved evaluations of corneal astigmatism and have helped minimize postoperative residual astigmatism, a perfect method to analyze preoperative corneal astigmatism has not yet been established.

Summary Perfect correction of astigmatism after toric IOL implantation by using accurate corneal astigmatism values is the goal of this surgical procedure. To achieve this, correct and precise measurements of corneal astigmatism to determine the magnitude and meridian should be obtained.

Original languageEnglish
Pages (from-to)34-38
Number of pages5
JournalCurrent Opinion in Ophthalmology
Volume26
Issue number1
DOIs
Publication statusPublished - 2015 Jan 1

Fingerprint

Intraocular Lens Implantation
Astigmatism
Meridians
Cataract
Refractive Errors

All Science Journal Classification (ASJC) codes

  • Ophthalmology

Cite this

@article{81b2ec6ebcde47ea8a062c4198a2a57f,
title = "Corneal astigmatism analysis for toric intraocular lens implantation: Precise measurements for perfect correction",
abstract = "Purpose of review Corneal astigmatism is a common refractive error observed in a significant percentage of cataract patients. Accurate measurements of the preexisting corneal astigmatism are essential in order to achieve the desired refractive outcome after toric intraocular lens (IOL) implantation. This article presents a comprehensive review of recent published literatures on methods for measuring preoperative corneal astigmatism for toric IOL implantation.Recent findings A variety of instruments has been introduced and used to measure the magnitude and meridian of corneal astigmatism during preoperative assessments of cataract patients. Instruments that consider both the anterior and posterior corneal surfaces as critical factors for measuring total corneal astigmatism are expected to provide better accuracy. Although these instruments facilitate improved evaluations of corneal astigmatism and have helped minimize postoperative residual astigmatism, a perfect method to analyze preoperative corneal astigmatism has not yet been established.Summary Perfect correction of astigmatism after toric IOL implantation by using accurate corneal astigmatism values is the goal of this surgical procedure. To achieve this, correct and precise measurements of corneal astigmatism to determine the magnitude and meridian should be obtained.",
author = "Hun Lee and Tae-im Kim and Eungkweon Kim",
year = "2015",
month = "1",
day = "1",
doi = "10.1097/ICU.0000000000000119",
language = "English",
volume = "26",
pages = "34--38",
journal = "Current Opinion in Ophthalmology",
issn = "1040-8738",
publisher = "Lippincott Williams and Wilkins",
number = "1",

}

TY - JOUR

T1 - Corneal astigmatism analysis for toric intraocular lens implantation

T2 - Precise measurements for perfect correction

AU - Lee, Hun

AU - Kim, Tae-im

AU - Kim, Eungkweon

PY - 2015/1/1

Y1 - 2015/1/1

N2 - Purpose of review Corneal astigmatism is a common refractive error observed in a significant percentage of cataract patients. Accurate measurements of the preexisting corneal astigmatism are essential in order to achieve the desired refractive outcome after toric intraocular lens (IOL) implantation. This article presents a comprehensive review of recent published literatures on methods for measuring preoperative corneal astigmatism for toric IOL implantation.Recent findings A variety of instruments has been introduced and used to measure the magnitude and meridian of corneal astigmatism during preoperative assessments of cataract patients. Instruments that consider both the anterior and posterior corneal surfaces as critical factors for measuring total corneal astigmatism are expected to provide better accuracy. Although these instruments facilitate improved evaluations of corneal astigmatism and have helped minimize postoperative residual astigmatism, a perfect method to analyze preoperative corneal astigmatism has not yet been established.Summary Perfect correction of astigmatism after toric IOL implantation by using accurate corneal astigmatism values is the goal of this surgical procedure. To achieve this, correct and precise measurements of corneal astigmatism to determine the magnitude and meridian should be obtained.

AB - Purpose of review Corneal astigmatism is a common refractive error observed in a significant percentage of cataract patients. Accurate measurements of the preexisting corneal astigmatism are essential in order to achieve the desired refractive outcome after toric intraocular lens (IOL) implantation. This article presents a comprehensive review of recent published literatures on methods for measuring preoperative corneal astigmatism for toric IOL implantation.Recent findings A variety of instruments has been introduced and used to measure the magnitude and meridian of corneal astigmatism during preoperative assessments of cataract patients. Instruments that consider both the anterior and posterior corneal surfaces as critical factors for measuring total corneal astigmatism are expected to provide better accuracy. Although these instruments facilitate improved evaluations of corneal astigmatism and have helped minimize postoperative residual astigmatism, a perfect method to analyze preoperative corneal astigmatism has not yet been established.Summary Perfect correction of astigmatism after toric IOL implantation by using accurate corneal astigmatism values is the goal of this surgical procedure. To achieve this, correct and precise measurements of corneal astigmatism to determine the magnitude and meridian should be obtained.

UR - http://www.scopus.com/inward/record.url?scp=84916887782&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84916887782&partnerID=8YFLogxK

U2 - 10.1097/ICU.0000000000000119

DO - 10.1097/ICU.0000000000000119

M3 - Review article

C2 - 25415298

AN - SCOPUS:84916887782

VL - 26

SP - 34

EP - 38

JO - Current Opinion in Ophthalmology

JF - Current Opinion in Ophthalmology

SN - 1040-8738

IS - 1

ER -