Critical current characteristic of various 2G HTS multi-stacked tapes depending on the low external magnetic field

J. Kim, W. S. Lee, H. Jin, T. K. Ko

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

2G HTS tapes are widely used for various electric machines. In addition, stacked or parallel connected HTS tapes are essentially used to raise transport current level for large capacity electric machines. Therefore, critical current characteristic of stacked tapes need to be studied. Recently developed 2G HTS tapes are fabricated with various defects doping so that tapes possess pinning center to improve the critical current characteristic. During this process, the critical current is determined minimum value in not perpendicular magnetic field but a specific magnetic field angle according to the reported research. However, the effects of magnetic field angle to critical current of multi-stacked 2G HTS tapes have not been examined. In this paper, field coil which is a race-track coil wound by using an HTS tape with iron-core was fabricated to apply angle adjustable magnetic field to the 2G HTS tape samples. We measured critical current of single and multi-stacked two tapes that have different characteristic depending on various magnetic field angle and magnitude in liquid nitrogen environment. Furthermore, results of single and multi-stacked tapes were compared and analyzed.

Original languageEnglish
Pages (from-to)27-31
Number of pages5
JournalProgress in Superconductivity and Cryogenics (PSAC)
Volume16
Issue number1
DOIs
Publication statusPublished - 2014 Mar

Fingerprint

Critical currents
Tapes
Magnetic fields
Electric machinery
Liquid nitrogen
Iron
Doping (additives)
Defects

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

Cite this

@article{b516a956c1e14457b3e487e97a1ae725,
title = "Critical current characteristic of various 2G HTS multi-stacked tapes depending on the low external magnetic field",
abstract = "2G HTS tapes are widely used for various electric machines. In addition, stacked or parallel connected HTS tapes are essentially used to raise transport current level for large capacity electric machines. Therefore, critical current characteristic of stacked tapes need to be studied. Recently developed 2G HTS tapes are fabricated with various defects doping so that tapes possess pinning center to improve the critical current characteristic. During this process, the critical current is determined minimum value in not perpendicular magnetic field but a specific magnetic field angle according to the reported research. However, the effects of magnetic field angle to critical current of multi-stacked 2G HTS tapes have not been examined. In this paper, field coil which is a race-track coil wound by using an HTS tape with iron-core was fabricated to apply angle adjustable magnetic field to the 2G HTS tape samples. We measured critical current of single and multi-stacked two tapes that have different characteristic depending on various magnetic field angle and magnitude in liquid nitrogen environment. Furthermore, results of single and multi-stacked tapes were compared and analyzed.",
author = "J. Kim and Lee, {W. S.} and H. Jin and Ko, {T. K.}",
year = "2014",
month = "3",
doi = "10.9714/psac.2014.16.1.027",
language = "English",
volume = "16",
pages = "27--31",
journal = "Progress in Superconductivity and Cryogenics (PSAC)",
issn = "1229-3008",
publisher = "Korea Institute of Applied Superconductivity and Cryogenics",
number = "1",

}

Critical current characteristic of various 2G HTS multi-stacked tapes depending on the low external magnetic field. / Kim, J.; Lee, W. S.; Jin, H.; Ko, T. K.

In: Progress in Superconductivity and Cryogenics (PSAC), Vol. 16, No. 1, 03.2014, p. 27-31.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Critical current characteristic of various 2G HTS multi-stacked tapes depending on the low external magnetic field

AU - Kim, J.

AU - Lee, W. S.

AU - Jin, H.

AU - Ko, T. K.

PY - 2014/3

Y1 - 2014/3

N2 - 2G HTS tapes are widely used for various electric machines. In addition, stacked or parallel connected HTS tapes are essentially used to raise transport current level for large capacity electric machines. Therefore, critical current characteristic of stacked tapes need to be studied. Recently developed 2G HTS tapes are fabricated with various defects doping so that tapes possess pinning center to improve the critical current characteristic. During this process, the critical current is determined minimum value in not perpendicular magnetic field but a specific magnetic field angle according to the reported research. However, the effects of magnetic field angle to critical current of multi-stacked 2G HTS tapes have not been examined. In this paper, field coil which is a race-track coil wound by using an HTS tape with iron-core was fabricated to apply angle adjustable magnetic field to the 2G HTS tape samples. We measured critical current of single and multi-stacked two tapes that have different characteristic depending on various magnetic field angle and magnitude in liquid nitrogen environment. Furthermore, results of single and multi-stacked tapes were compared and analyzed.

AB - 2G HTS tapes are widely used for various electric machines. In addition, stacked or parallel connected HTS tapes are essentially used to raise transport current level for large capacity electric machines. Therefore, critical current characteristic of stacked tapes need to be studied. Recently developed 2G HTS tapes are fabricated with various defects doping so that tapes possess pinning center to improve the critical current characteristic. During this process, the critical current is determined minimum value in not perpendicular magnetic field but a specific magnetic field angle according to the reported research. However, the effects of magnetic field angle to critical current of multi-stacked 2G HTS tapes have not been examined. In this paper, field coil which is a race-track coil wound by using an HTS tape with iron-core was fabricated to apply angle adjustable magnetic field to the 2G HTS tape samples. We measured critical current of single and multi-stacked two tapes that have different characteristic depending on various magnetic field angle and magnitude in liquid nitrogen environment. Furthermore, results of single and multi-stacked tapes were compared and analyzed.

UR - http://www.scopus.com/inward/record.url?scp=84897531171&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84897531171&partnerID=8YFLogxK

U2 - 10.9714/psac.2014.16.1.027

DO - 10.9714/psac.2014.16.1.027

M3 - Article

AN - SCOPUS:84897531171

VL - 16

SP - 27

EP - 31

JO - Progress in Superconductivity and Cryogenics (PSAC)

JF - Progress in Superconductivity and Cryogenics (PSAC)

SN - 1229-3008

IS - 1

ER -