Design and implementation of biomedical SoC for implantable cardioverter defibrillators

Kilhwan Kim, Unsun Cho, Yunho Jung, Jaeseok Kim

Research output: Chapter in Book/Report/Conference proceedingConference contribution

3 Citations (Scopus)

Abstract

In this paper, a biomedical processor was developed for implantable cardioverter defibrillators (ICDs), which delivers appropriate prescriptions for atrial tachycardia and fibrillation to a pacing module of ICD. The diagnosis of heart conditions is determined based on atrial electrograms (EGMs) as sensed from within the heart. The biomedical processor is implemented into a single chip including analog circuit elements. The chip is fabricated in a 0.35 μm CMOS technology, and the chip area is 3.8 × 2.7 mm2.

Original languageEnglish
Title of host publication2007 IEEE Asian Solid-State Circuits Conference, A-SSCC
Pages248-251
Number of pages4
DOIs
Publication statusPublished - 2007 Dec 1
Event2007 IEEE Asian Solid-State Circuits Conference, A-SSCC - Jeju, Korea, Republic of
Duration: 2007 Nov 122007 Nov 14

Publication series

Name2007 IEEE Asian Solid-State Circuits Conference, A-SSCC

Other

Other2007 IEEE Asian Solid-State Circuits Conference, A-SSCC
CountryKorea, Republic of
CityJeju
Period07/11/1207/11/14

Fingerprint

Implantable cardioverter defibrillators
Analog circuits
System-on-chip

All Science Journal Classification (ASJC) codes

  • Hardware and Architecture
  • Electrical and Electronic Engineering

Cite this

Kim, K., Cho, U., Jung, Y., & Kim, J. (2007). Design and implementation of biomedical SoC for implantable cardioverter defibrillators. In 2007 IEEE Asian Solid-State Circuits Conference, A-SSCC (pp. 248-251). [4425777] (2007 IEEE Asian Solid-State Circuits Conference, A-SSCC). https://doi.org/10.1109/ASSCC.2007.4425777
Kim, Kilhwan ; Cho, Unsun ; Jung, Yunho ; Kim, Jaeseok. / Design and implementation of biomedical SoC for implantable cardioverter defibrillators. 2007 IEEE Asian Solid-State Circuits Conference, A-SSCC. 2007. pp. 248-251 (2007 IEEE Asian Solid-State Circuits Conference, A-SSCC).
@inproceedings{570523b60e2f43b0b72bdd2097cf706b,
title = "Design and implementation of biomedical SoC for implantable cardioverter defibrillators",
abstract = "In this paper, a biomedical processor was developed for implantable cardioverter defibrillators (ICDs), which delivers appropriate prescriptions for atrial tachycardia and fibrillation to a pacing module of ICD. The diagnosis of heart conditions is determined based on atrial electrograms (EGMs) as sensed from within the heart. The biomedical processor is implemented into a single chip including analog circuit elements. The chip is fabricated in a 0.35 μm CMOS technology, and the chip area is 3.8 × 2.7 mm2.",
author = "Kilhwan Kim and Unsun Cho and Yunho Jung and Jaeseok Kim",
year = "2007",
month = "12",
day = "1",
doi = "10.1109/ASSCC.2007.4425777",
language = "English",
isbn = "1424413605",
series = "2007 IEEE Asian Solid-State Circuits Conference, A-SSCC",
pages = "248--251",
booktitle = "2007 IEEE Asian Solid-State Circuits Conference, A-SSCC",

}

Kim, K, Cho, U, Jung, Y & Kim, J 2007, Design and implementation of biomedical SoC for implantable cardioverter defibrillators. in 2007 IEEE Asian Solid-State Circuits Conference, A-SSCC., 4425777, 2007 IEEE Asian Solid-State Circuits Conference, A-SSCC, pp. 248-251, 2007 IEEE Asian Solid-State Circuits Conference, A-SSCC, Jeju, Korea, Republic of, 07/11/12. https://doi.org/10.1109/ASSCC.2007.4425777

Design and implementation of biomedical SoC for implantable cardioverter defibrillators. / Kim, Kilhwan; Cho, Unsun; Jung, Yunho; Kim, Jaeseok.

2007 IEEE Asian Solid-State Circuits Conference, A-SSCC. 2007. p. 248-251 4425777 (2007 IEEE Asian Solid-State Circuits Conference, A-SSCC).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Design and implementation of biomedical SoC for implantable cardioverter defibrillators

AU - Kim, Kilhwan

AU - Cho, Unsun

AU - Jung, Yunho

AU - Kim, Jaeseok

PY - 2007/12/1

Y1 - 2007/12/1

N2 - In this paper, a biomedical processor was developed for implantable cardioverter defibrillators (ICDs), which delivers appropriate prescriptions for atrial tachycardia and fibrillation to a pacing module of ICD. The diagnosis of heart conditions is determined based on atrial electrograms (EGMs) as sensed from within the heart. The biomedical processor is implemented into a single chip including analog circuit elements. The chip is fabricated in a 0.35 μm CMOS technology, and the chip area is 3.8 × 2.7 mm2.

AB - In this paper, a biomedical processor was developed for implantable cardioverter defibrillators (ICDs), which delivers appropriate prescriptions for atrial tachycardia and fibrillation to a pacing module of ICD. The diagnosis of heart conditions is determined based on atrial electrograms (EGMs) as sensed from within the heart. The biomedical processor is implemented into a single chip including analog circuit elements. The chip is fabricated in a 0.35 μm CMOS technology, and the chip area is 3.8 × 2.7 mm2.

UR - http://www.scopus.com/inward/record.url?scp=51349119782&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=51349119782&partnerID=8YFLogxK

U2 - 10.1109/ASSCC.2007.4425777

DO - 10.1109/ASSCC.2007.4425777

M3 - Conference contribution

AN - SCOPUS:51349119782

SN - 1424413605

SN - 9781424413607

T3 - 2007 IEEE Asian Solid-State Circuits Conference, A-SSCC

SP - 248

EP - 251

BT - 2007 IEEE Asian Solid-State Circuits Conference, A-SSCC

ER -

Kim K, Cho U, Jung Y, Kim J. Design and implementation of biomedical SoC for implantable cardioverter defibrillators. In 2007 IEEE Asian Solid-State Circuits Conference, A-SSCC. 2007. p. 248-251. 4425777. (2007 IEEE Asian Solid-State Circuits Conference, A-SSCC). https://doi.org/10.1109/ASSCC.2007.4425777