@inproceedings{df59ea7a9ba945ef8b6221a5394e9040,
title = "Design of the E-field probe with variable resistors",
abstract = "This paper shows a development of an E-field probe in a personal exposure measurement meter for occupational exposure. To evaluate an exposed E-field near the human body, the personal exposure measurement meter is used. This device composes of the E-field probe and a readout device. The probe is consist of three orthogonal small dipoles with diode and lossy transmission lines with chip resistors. To improve the probe sensitivity, the use of various chip resistors has been proposed in this paper. The bandwidth of the designed E-field probe is from 800 MHz to 2.5 GHz for mobile communication bands. The fabricated E-field probe with variable resistors and the characteristics of the probe such as linearity and isotropic deviation are presented in this paper.",
author = "Kwak, {Sang Il} and Kwon, {Jong Hwa} and Yoon, {Young Joong}",
year = "2015",
month = jan,
day = "28",
doi = "10.1109/ISANP.2014.7026676",
language = "English",
series = "ISAP 2014 - 2014 International Symposium on Antennas and Propagation, Conference Proceedings",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "353--354",
booktitle = "ISAP 2014 - 2014 International Symposium on Antennas and Propagation, Conference Proceedings",
address = "United States",
note = "2014 International Symposium on Antennas and Propagation, ISAP 2014 ; Conference date: 02-12-2014 Through 05-12-2014",
}