Development of a low noise preamplifier for the detection and position determination of single electrons in a cerenkov ring imaging detector by charge division

E. Spencer, P. Coyle, D. Williams, Y. J. Kwon, D. Leith, D. Mcshurley, G. Oxoby, B. Ratcliff, P. Rensing, D. Schultz, S. Shapiro, N. Toge

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

A preamplifier having 500 electrons noise (rms) has been developed for the detection and location of single electrons in a CRID detector at the SLD. A single channel contains preamp, RC-CR shaper, gain adjustment, driver, and calibration cir-cuitry. Noise and linearity measurements are presented.

Original languageEnglish
Pages (from-to)231-236
Number of pages6
JournalIEEE Transactions on Nuclear Science
Volume35
Issue number1
DOIs
Publication statusPublished - 1988 Feb

Fingerprint

preamplifiers
low noise
division
Detectors
Imaging techniques
shapers
Electrons
rings
detectors
noise measurement
linearity
electrons
adjusting
Calibration

All Science Journal Classification (ASJC) codes

  • Nuclear and High Energy Physics
  • Nuclear Energy and Engineering
  • Electrical and Electronic Engineering

Cite this

Spencer, E. ; Coyle, P. ; Williams, D. ; Kwon, Y. J. ; Leith, D. ; Mcshurley, D. ; Oxoby, G. ; Ratcliff, B. ; Rensing, P. ; Schultz, D. ; Shapiro, S. ; Toge, N. / Development of a low noise preamplifier for the detection and position determination of single electrons in a cerenkov ring imaging detector by charge division. In: IEEE Transactions on Nuclear Science. 1988 ; Vol. 35, No. 1. pp. 231-236.
@article{e64d897a08f34042998ecd3851d86ffb,
title = "Development of a low noise preamplifier for the detection and position determination of single electrons in a cerenkov ring imaging detector by charge division",
abstract = "A preamplifier having 500 electrons noise (rms) has been developed for the detection and location of single electrons in a CRID detector at the SLD. A single channel contains preamp, RC-CR shaper, gain adjustment, driver, and calibration cir-cuitry. Noise and linearity measurements are presented.",
author = "E. Spencer and P. Coyle and D. Williams and Kwon, {Y. J.} and D. Leith and D. Mcshurley and G. Oxoby and B. Ratcliff and P. Rensing and D. Schultz and S. Shapiro and N. Toge",
year = "1988",
month = "2",
doi = "10.1109/23.12714",
language = "English",
volume = "35",
pages = "231--236",
journal = "IEEE Transactions on Nuclear Science",
issn = "0018-9499",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "1",

}

Spencer, E, Coyle, P, Williams, D, Kwon, YJ, Leith, D, Mcshurley, D, Oxoby, G, Ratcliff, B, Rensing, P, Schultz, D, Shapiro, S & Toge, N 1988, 'Development of a low noise preamplifier for the detection and position determination of single electrons in a cerenkov ring imaging detector by charge division', IEEE Transactions on Nuclear Science, vol. 35, no. 1, pp. 231-236. https://doi.org/10.1109/23.12714

Development of a low noise preamplifier for the detection and position determination of single electrons in a cerenkov ring imaging detector by charge division. / Spencer, E.; Coyle, P.; Williams, D.; Kwon, Y. J.; Leith, D.; Mcshurley, D.; Oxoby, G.; Ratcliff, B.; Rensing, P.; Schultz, D.; Shapiro, S.; Toge, N.

In: IEEE Transactions on Nuclear Science, Vol. 35, No. 1, 02.1988, p. 231-236.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Development of a low noise preamplifier for the detection and position determination of single electrons in a cerenkov ring imaging detector by charge division

AU - Spencer, E.

AU - Coyle, P.

AU - Williams, D.

AU - Kwon, Y. J.

AU - Leith, D.

AU - Mcshurley, D.

AU - Oxoby, G.

AU - Ratcliff, B.

AU - Rensing, P.

AU - Schultz, D.

AU - Shapiro, S.

AU - Toge, N.

PY - 1988/2

Y1 - 1988/2

N2 - A preamplifier having 500 electrons noise (rms) has been developed for the detection and location of single electrons in a CRID detector at the SLD. A single channel contains preamp, RC-CR shaper, gain adjustment, driver, and calibration cir-cuitry. Noise and linearity measurements are presented.

AB - A preamplifier having 500 electrons noise (rms) has been developed for the detection and location of single electrons in a CRID detector at the SLD. A single channel contains preamp, RC-CR shaper, gain adjustment, driver, and calibration cir-cuitry. Noise and linearity measurements are presented.

UR - http://www.scopus.com/inward/record.url?scp=84912916366&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84912916366&partnerID=8YFLogxK

U2 - 10.1109/23.12714

DO - 10.1109/23.12714

M3 - Article

AN - SCOPUS:84912916366

VL - 35

SP - 231

EP - 236

JO - IEEE Transactions on Nuclear Science

JF - IEEE Transactions on Nuclear Science

SN - 0018-9499

IS - 1

ER -