Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients with an Intraoral Scanner and Old Complete Denture

Xueyin An, Hyun Woo Yang, Byungho Choi

Research output: Contribution to journalArticle

Abstract

A double-scan procedure is commonly performed in the process of fabricating an implant surgical template; however, this entails the disadvantage of recording 2 cone beam computed tomography (CBCT) scans requiring additional time, effort, and costs. The purpose of this article is to introduce a digital protocol to acquire adequate preoperative diagnostic information for a fully edentulous patient, using the existing complete denture with a metal framework, an intraoral scanner, and CBCT.

Original languageEnglish
Pages (from-to)715-718
Number of pages4
JournalJournal of Prosthodontics
Volume28
Issue number6
DOIs
Publication statusPublished - 2019 Jul 1

Fingerprint

Complete Denture
Cone-Beam Computed Tomography
Workflow
Metals
Costs and Cost Analysis

All Science Journal Classification (ASJC) codes

  • Dentistry(all)

Cite this

@article{84ecc4ab79da44eaa0a62874d81b2a3b,
title = "Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients with an Intraoral Scanner and Old Complete Denture",
abstract = "A double-scan procedure is commonly performed in the process of fabricating an implant surgical template; however, this entails the disadvantage of recording 2 cone beam computed tomography (CBCT) scans requiring additional time, effort, and costs. The purpose of this article is to introduce a digital protocol to acquire adequate preoperative diagnostic information for a fully edentulous patient, using the existing complete denture with a metal framework, an intraoral scanner, and CBCT.",
author = "Xueyin An and Yang, {Hyun Woo} and Byungho Choi",
year = "2019",
month = "7",
day = "1",
doi = "10.1111/jopr.13073",
language = "English",
volume = "28",
pages = "715--718",
journal = "Journal of Prosthodontics",
issn = "1059-941X",
publisher = "Wiley-Blackwell",
number = "6",

}

Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients with an Intraoral Scanner and Old Complete Denture. / An, Xueyin; Yang, Hyun Woo; Choi, Byungho.

In: Journal of Prosthodontics, Vol. 28, No. 6, 01.07.2019, p. 715-718.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients with an Intraoral Scanner and Old Complete Denture

AU - An, Xueyin

AU - Yang, Hyun Woo

AU - Choi, Byungho

PY - 2019/7/1

Y1 - 2019/7/1

N2 - A double-scan procedure is commonly performed in the process of fabricating an implant surgical template; however, this entails the disadvantage of recording 2 cone beam computed tomography (CBCT) scans requiring additional time, effort, and costs. The purpose of this article is to introduce a digital protocol to acquire adequate preoperative diagnostic information for a fully edentulous patient, using the existing complete denture with a metal framework, an intraoral scanner, and CBCT.

AB - A double-scan procedure is commonly performed in the process of fabricating an implant surgical template; however, this entails the disadvantage of recording 2 cone beam computed tomography (CBCT) scans requiring additional time, effort, and costs. The purpose of this article is to introduce a digital protocol to acquire adequate preoperative diagnostic information for a fully edentulous patient, using the existing complete denture with a metal framework, an intraoral scanner, and CBCT.

UR - http://www.scopus.com/inward/record.url?scp=85068030830&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85068030830&partnerID=8YFLogxK

U2 - 10.1111/jopr.13073

DO - 10.1111/jopr.13073

M3 - Article

VL - 28

SP - 715

EP - 718

JO - Journal of Prosthodontics

JF - Journal of Prosthodontics

SN - 1059-941X

IS - 6

ER -