TY - JOUR
T1 - Early outcomes of percutaneous pulmonary valve implantation with pulsta and melody valves
T2 - The first report from korea
AU - Kim, Ah Young
AU - Jung, Jo Won
AU - Jung, Se Yong
AU - Shin, Jae Il
AU - Eun, Lucy Youngmin
AU - Kim, Nam Kyun
AU - Choi, Jae Young
N1 - Publisher Copyright:
© 2020 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2020/9
Y1 - 2020/9
N2 - Percutaneous pulmonary valve implantation (PPVI) is used to treat pulmonary stenosis (PS) or pulmonary regurgitation (PR). We described our experience with PPVI, specifically valve-in-valve transcatheter pulmonary valve replacement using the Melody valve and novel self-expandable systems using the Pulsta valve. We reviewed data from 42 patients undergoing PPVI. Twenty-nine patients had Melody valves in mostly bioprosthetic valves, valved conduits, and homografts in the pulmonary position. Following Melody valve implantation, the peak right ventricle-to-pulmonary artery gradient decreased from 51.3 ± 11.5 to 16.7 ± 3.3 mmHg and right ventricular systolic pressure fell from 70.0 ± 16.8 to 41.3 ± 17.8 mmHg. Thirteen patients with native right ventricular outflow tract (RVOT) lesions and homograft underwent PPVI with the new self-expandable Pulsta valve—a nitinol wire stent mounted with a trileaflet porcine pericardial valve. Following Pulsta valve implantation, cardiac magnetic resonance imaging showed a decreased PR fraction and that the right ventricular end-diastolic volume index decreased from 166.1 ± 11.9 to 123.6 ± 12.4 mL/m2. There were no mortality, severe procedural morbidity, or valve-related complications. At the mean 14.2 month (4–57 months) follow-up, no patients had more than mild PR. PPVI using Melody and Pulsta valves was first shown to provide excellent early outcomes without serious adverse event in most patients with RVOT dysfunction in Korea.
AB - Percutaneous pulmonary valve implantation (PPVI) is used to treat pulmonary stenosis (PS) or pulmonary regurgitation (PR). We described our experience with PPVI, specifically valve-in-valve transcatheter pulmonary valve replacement using the Melody valve and novel self-expandable systems using the Pulsta valve. We reviewed data from 42 patients undergoing PPVI. Twenty-nine patients had Melody valves in mostly bioprosthetic valves, valved conduits, and homografts in the pulmonary position. Following Melody valve implantation, the peak right ventricle-to-pulmonary artery gradient decreased from 51.3 ± 11.5 to 16.7 ± 3.3 mmHg and right ventricular systolic pressure fell from 70.0 ± 16.8 to 41.3 ± 17.8 mmHg. Thirteen patients with native right ventricular outflow tract (RVOT) lesions and homograft underwent PPVI with the new self-expandable Pulsta valve—a nitinol wire stent mounted with a trileaflet porcine pericardial valve. Following Pulsta valve implantation, cardiac magnetic resonance imaging showed a decreased PR fraction and that the right ventricular end-diastolic volume index decreased from 166.1 ± 11.9 to 123.6 ± 12.4 mL/m2. There were no mortality, severe procedural morbidity, or valve-related complications. At the mean 14.2 month (4–57 months) follow-up, no patients had more than mild PR. PPVI using Melody and Pulsta valves was first shown to provide excellent early outcomes without serious adverse event in most patients with RVOT dysfunction in Korea.
UR - http://www.scopus.com/inward/record.url?scp=85114283525&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85114283525&partnerID=8YFLogxK
U2 - 10.3390/jcm9092769
DO - 10.3390/jcm9092769
M3 - Article
AN - SCOPUS:85114283525
SN - 2077-0383
VL - 9
SP - 1
EP - 14
JO - Journal of Clinical Medicine
JF - Journal of Clinical Medicine
IS - 9
M1 - 2769
ER -