Effect of bone cement volume and stiffness on occurrences of adjacent vertebral fractures after vertebroplasty

Jin Myung Kim, DongAh Shin, Dong Hak Byun, Hyung Sun Kim, Sohee Kim, Hyoung Ihl Kim

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Objective: The purpose of this study is to find the optimal stiffness and volume of bone cement and their biomechanical effects on the adjacent vertebrae to determine a better strategy for conducting vertebroplasty. Methods: A three-dimensional finite-element model of a functional spinal unit was developed using computed tomography scans of a normal motion segment, comprising the T11, T12 and L1 vertebrae. Volumes of bone cement, with appropriate mechanical properties, were inserted into the trabecular core of the T12 vertebra. Parametric studies were done by varying the volume and stiffness of the bone cement. Results: When the bone cement filling volume reached 30% of the volume of a vertebral body, the level of stiffness was restored to that of normal bone, and when higher bone cement exceeded 30% of the volume, the result was stiffness in excess of that of normal bone. When the bone cement volume was varied, local stress in the bony structures (cortical shell, trabecular bone and endplate) of each vertebra monotonically increased. Low-modulus bone cement has the effect of reducing strain in the augmented body, but only in cases of relatively high volumes of bone cement (>50%). Furthermore, varying the stiffness of bone cement has a negligible effect on the stress distribution of vertebral bodies. Conclusion: The volume of cement was considered to be the most important determinant in endplate fracture. Changing the stiffness of bone cement has a negligible effect on the stress distribution of vertebral bodies.

Original languageEnglish
Pages (from-to)435-440
Number of pages6
JournalJournal of Korean Neurosurgical Society
Volume52
Issue number5
DOIs
Publication statusPublished - 2012 Jan 1

Fingerprint

Vertebroplasty
Bone Cements
Spine
Bone and Bones
Tomography

All Science Journal Classification (ASJC) codes

  • Surgery
  • Neuroscience(all)
  • Clinical Neurology

Cite this

Kim, Jin Myung ; Shin, DongAh ; Byun, Dong Hak ; Kim, Hyung Sun ; Kim, Sohee ; Kim, Hyoung Ihl. / Effect of bone cement volume and stiffness on occurrences of adjacent vertebral fractures after vertebroplasty. In: Journal of Korean Neurosurgical Society. 2012 ; Vol. 52, No. 5. pp. 435-440.
@article{78820a2654f74244930175cea3270da9,
title = "Effect of bone cement volume and stiffness on occurrences of adjacent vertebral fractures after vertebroplasty",
abstract = "Objective: The purpose of this study is to find the optimal stiffness and volume of bone cement and their biomechanical effects on the adjacent vertebrae to determine a better strategy for conducting vertebroplasty. Methods: A three-dimensional finite-element model of a functional spinal unit was developed using computed tomography scans of a normal motion segment, comprising the T11, T12 and L1 vertebrae. Volumes of bone cement, with appropriate mechanical properties, were inserted into the trabecular core of the T12 vertebra. Parametric studies were done by varying the volume and stiffness of the bone cement. Results: When the bone cement filling volume reached 30{\%} of the volume of a vertebral body, the level of stiffness was restored to that of normal bone, and when higher bone cement exceeded 30{\%} of the volume, the result was stiffness in excess of that of normal bone. When the bone cement volume was varied, local stress in the bony structures (cortical shell, trabecular bone and endplate) of each vertebra monotonically increased. Low-modulus bone cement has the effect of reducing strain in the augmented body, but only in cases of relatively high volumes of bone cement (>50{\%}). Furthermore, varying the stiffness of bone cement has a negligible effect on the stress distribution of vertebral bodies. Conclusion: The volume of cement was considered to be the most important determinant in endplate fracture. Changing the stiffness of bone cement has a negligible effect on the stress distribution of vertebral bodies.",
author = "Kim, {Jin Myung} and DongAh Shin and Byun, {Dong Hak} and Kim, {Hyung Sun} and Sohee Kim and Kim, {Hyoung Ihl}",
year = "2012",
month = "1",
day = "1",
doi = "10.3340/jkns.2012.52.5.435",
language = "English",
volume = "52",
pages = "435--440",
journal = "Journal of Korean Neurosurgical Society",
issn = "2005-3711",
publisher = "Daehan sin'gyeong oe'gwa haghoe",
number = "5",

}

Effect of bone cement volume and stiffness on occurrences of adjacent vertebral fractures after vertebroplasty. / Kim, Jin Myung; Shin, DongAh; Byun, Dong Hak; Kim, Hyung Sun; Kim, Sohee; Kim, Hyoung Ihl.

In: Journal of Korean Neurosurgical Society, Vol. 52, No. 5, 01.01.2012, p. 435-440.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Effect of bone cement volume and stiffness on occurrences of adjacent vertebral fractures after vertebroplasty

AU - Kim, Jin Myung

AU - Shin, DongAh

AU - Byun, Dong Hak

AU - Kim, Hyung Sun

AU - Kim, Sohee

AU - Kim, Hyoung Ihl

PY - 2012/1/1

Y1 - 2012/1/1

N2 - Objective: The purpose of this study is to find the optimal stiffness and volume of bone cement and their biomechanical effects on the adjacent vertebrae to determine a better strategy for conducting vertebroplasty. Methods: A three-dimensional finite-element model of a functional spinal unit was developed using computed tomography scans of a normal motion segment, comprising the T11, T12 and L1 vertebrae. Volumes of bone cement, with appropriate mechanical properties, were inserted into the trabecular core of the T12 vertebra. Parametric studies were done by varying the volume and stiffness of the bone cement. Results: When the bone cement filling volume reached 30% of the volume of a vertebral body, the level of stiffness was restored to that of normal bone, and when higher bone cement exceeded 30% of the volume, the result was stiffness in excess of that of normal bone. When the bone cement volume was varied, local stress in the bony structures (cortical shell, trabecular bone and endplate) of each vertebra monotonically increased. Low-modulus bone cement has the effect of reducing strain in the augmented body, but only in cases of relatively high volumes of bone cement (>50%). Furthermore, varying the stiffness of bone cement has a negligible effect on the stress distribution of vertebral bodies. Conclusion: The volume of cement was considered to be the most important determinant in endplate fracture. Changing the stiffness of bone cement has a negligible effect on the stress distribution of vertebral bodies.

AB - Objective: The purpose of this study is to find the optimal stiffness and volume of bone cement and their biomechanical effects on the adjacent vertebrae to determine a better strategy for conducting vertebroplasty. Methods: A three-dimensional finite-element model of a functional spinal unit was developed using computed tomography scans of a normal motion segment, comprising the T11, T12 and L1 vertebrae. Volumes of bone cement, with appropriate mechanical properties, were inserted into the trabecular core of the T12 vertebra. Parametric studies were done by varying the volume and stiffness of the bone cement. Results: When the bone cement filling volume reached 30% of the volume of a vertebral body, the level of stiffness was restored to that of normal bone, and when higher bone cement exceeded 30% of the volume, the result was stiffness in excess of that of normal bone. When the bone cement volume was varied, local stress in the bony structures (cortical shell, trabecular bone and endplate) of each vertebra monotonically increased. Low-modulus bone cement has the effect of reducing strain in the augmented body, but only in cases of relatively high volumes of bone cement (>50%). Furthermore, varying the stiffness of bone cement has a negligible effect on the stress distribution of vertebral bodies. Conclusion: The volume of cement was considered to be the most important determinant in endplate fracture. Changing the stiffness of bone cement has a negligible effect on the stress distribution of vertebral bodies.

UR - http://www.scopus.com/inward/record.url?scp=84871748521&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84871748521&partnerID=8YFLogxK

U2 - 10.3340/jkns.2012.52.5.435

DO - 10.3340/jkns.2012.52.5.435

M3 - Article

AN - SCOPUS:84871748521

VL - 52

SP - 435

EP - 440

JO - Journal of Korean Neurosurgical Society

JF - Journal of Korean Neurosurgical Society

SN - 2005-3711

IS - 5

ER -