Abstract

Purpose: We hypothesized that the predictability of stroke volume variation (SVV) on fluid responsiveness would be reduced in patients with coronary disease who have wide pulse pressure (PP). Methods: Sixty-six patients undergoing coronary surgery were divided into 2 groups according to the PP measured 1 day before surgery: normal PP (n = 33, PP ≤ 60 mm Hg) or wide PP (n = 33, PP > 60 mm Hg). After applying mechanical ventilation, hemodynamic parameters (including SVV measured by the FloTrac/Vigileo system [Edwards Lifesciences, Irvine, Calif]) were recorded before and 10 minutes after fluid replacement in a closed-chest condition. Prediction of fluid responsiveness was tested by calculating the area under the receiver operating characteristic curves. Results: Twenty-one patients in the normal PP and 16 patients in the wide PP condition were fluid responders. The area under the receiver operating characteristic curves of SVV to predict fluid responsiveness were 0.808 (P = .022) and 0.609 (P = .288) in the normal PP and wide PP patients, respectively. In the normal PP condition, a SVV value of 13% discriminated between fluid responders and nonresponders with a sensitivity of 76% and a specificity of 67%. Conclusions: In contrast to patients with normal PP, SVV does not predict fluid responsiveness in patients with coronary disease who have wide PP.

Original languageEnglish
Pages (from-to)318.e1-318.e7
JournalJournal of Critical Care
Volume28
Issue number3
DOIs
Publication statusPublished - 2013 Jan 1

Fingerprint

Stroke Volume
Coronary Disease
Blood Pressure
ROC Curve
Ambulatory Surgical Procedures
Artificial Respiration
Thorax
Hemodynamics

All Science Journal Classification (ASJC) codes

  • Critical Care and Intensive Care Medicine

Cite this

@article{e4a1c946e0514770922cde492e0b3384,
title = "Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease",
abstract = "Purpose: We hypothesized that the predictability of stroke volume variation (SVV) on fluid responsiveness would be reduced in patients with coronary disease who have wide pulse pressure (PP). Methods: Sixty-six patients undergoing coronary surgery were divided into 2 groups according to the PP measured 1 day before surgery: normal PP (n = 33, PP ≤ 60 mm Hg) or wide PP (n = 33, PP > 60 mm Hg). After applying mechanical ventilation, hemodynamic parameters (including SVV measured by the FloTrac/Vigileo system [Edwards Lifesciences, Irvine, Calif]) were recorded before and 10 minutes after fluid replacement in a closed-chest condition. Prediction of fluid responsiveness was tested by calculating the area under the receiver operating characteristic curves. Results: Twenty-one patients in the normal PP and 16 patients in the wide PP condition were fluid responders. The area under the receiver operating characteristic curves of SVV to predict fluid responsiveness were 0.808 (P = .022) and 0.609 (P = .288) in the normal PP and wide PP patients, respectively. In the normal PP condition, a SVV value of 13{\%} discriminated between fluid responders and nonresponders with a sensitivity of 76{\%} and a specificity of 67{\%}. Conclusions: In contrast to patients with normal PP, SVV does not predict fluid responsiveness in patients with coronary disease who have wide PP.",
author = "Kim, {So Yeon} and Young Song and Shim, {Jae Kwang} and Younglan Kwak",
year = "2013",
month = "1",
day = "1",
doi = "10.1016/j.jcrc.2012.09.011",
language = "English",
volume = "28",
pages = "318.e1--318.e7",
journal = "Journal of Critical Care",
issn = "0883-9441",
publisher = "Elsevier BV",
number = "3",

}

Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease. / Kim, So Yeon; Song, Young; Shim, Jae Kwang; Kwak, Younglan.

In: Journal of Critical Care, Vol. 28, No. 3, 01.01.2013, p. 318.e1-318.e7.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease

AU - Kim, So Yeon

AU - Song, Young

AU - Shim, Jae Kwang

AU - Kwak, Younglan

PY - 2013/1/1

Y1 - 2013/1/1

N2 - Purpose: We hypothesized that the predictability of stroke volume variation (SVV) on fluid responsiveness would be reduced in patients with coronary disease who have wide pulse pressure (PP). Methods: Sixty-six patients undergoing coronary surgery were divided into 2 groups according to the PP measured 1 day before surgery: normal PP (n = 33, PP ≤ 60 mm Hg) or wide PP (n = 33, PP > 60 mm Hg). After applying mechanical ventilation, hemodynamic parameters (including SVV measured by the FloTrac/Vigileo system [Edwards Lifesciences, Irvine, Calif]) were recorded before and 10 minutes after fluid replacement in a closed-chest condition. Prediction of fluid responsiveness was tested by calculating the area under the receiver operating characteristic curves. Results: Twenty-one patients in the normal PP and 16 patients in the wide PP condition were fluid responders. The area under the receiver operating characteristic curves of SVV to predict fluid responsiveness were 0.808 (P = .022) and 0.609 (P = .288) in the normal PP and wide PP patients, respectively. In the normal PP condition, a SVV value of 13% discriminated between fluid responders and nonresponders with a sensitivity of 76% and a specificity of 67%. Conclusions: In contrast to patients with normal PP, SVV does not predict fluid responsiveness in patients with coronary disease who have wide PP.

AB - Purpose: We hypothesized that the predictability of stroke volume variation (SVV) on fluid responsiveness would be reduced in patients with coronary disease who have wide pulse pressure (PP). Methods: Sixty-six patients undergoing coronary surgery were divided into 2 groups according to the PP measured 1 day before surgery: normal PP (n = 33, PP ≤ 60 mm Hg) or wide PP (n = 33, PP > 60 mm Hg). After applying mechanical ventilation, hemodynamic parameters (including SVV measured by the FloTrac/Vigileo system [Edwards Lifesciences, Irvine, Calif]) were recorded before and 10 minutes after fluid replacement in a closed-chest condition. Prediction of fluid responsiveness was tested by calculating the area under the receiver operating characteristic curves. Results: Twenty-one patients in the normal PP and 16 patients in the wide PP condition were fluid responders. The area under the receiver operating characteristic curves of SVV to predict fluid responsiveness were 0.808 (P = .022) and 0.609 (P = .288) in the normal PP and wide PP patients, respectively. In the normal PP condition, a SVV value of 13% discriminated between fluid responders and nonresponders with a sensitivity of 76% and a specificity of 67%. Conclusions: In contrast to patients with normal PP, SVV does not predict fluid responsiveness in patients with coronary disease who have wide PP.

UR - http://www.scopus.com/inward/record.url?scp=84876859651&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84876859651&partnerID=8YFLogxK

U2 - 10.1016/j.jcrc.2012.09.011

DO - 10.1016/j.jcrc.2012.09.011

M3 - Article

C2 - 23122680

AN - SCOPUS:84876859651

VL - 28

SP - 318.e1-318.e7

JO - Journal of Critical Care

JF - Journal of Critical Care

SN - 0883-9441

IS - 3

ER -