TY - JOUR
T1 - Effectiveness of kaolin-impregnated hemostatic gauze use in preperitoneal pelvic packing for patients with pelvic fractures and hemodynamic instability
T2 - A propensity score matching analysis
AU - Kim, Kwangmin
AU - Shim, Hongjin
AU - Jung, Pil Young
AU - Kim, Seongyup
AU - Choi, Young Un
AU - Bae, Keum Seok
AU - Lee, Jung Kuk
AU - Jang, Ji Young
N1 - Publisher Copyright:
Copyright © 2020 Kim et al.
PY - 2020/7
Y1 - 2020/7
N2 - Introduction: We evaluated the effectiveness of kaolin-impregnated hemostatic gauze use in preperitoneal pelvic packing (PPP) for patients with hemodynamic instability due to severe pelvic fractures. Materials and methods: Between May 2014 and October 2018, 53 of 75 patients who underwent PPP due to hemodynamic instability induced by pelvic fracture were enrolled. Their medical records were prospectively collected and retrospectively analyzed. QuikClot combat gauze (hydrophilic gauze impregnated with kaolin) and general surgical tape were used in 21 patients, while general surgical tape was used in the remaining 32 patients. Results: As there were differences in the characteristics of patients between the hemostatic gauze (HG) group and control group, propensity score matching (PSM) was performed to adjust for age, sex, and lactate levels. After PSM, the clinical characteristics between the two groups became similar. There were no differences in the rates of mortality and hemorrhageinduced mortality between the two groups. However, the packed red blood cell (RBC) requirement for an additional 12 hours in the HG group was significantly lower than that in the control group (4.1 ± 3.5 vs. 7.6 ± 6.1 units, p = 0.035). The lengths of intensive care unit and hospital stays tended to be shorter in the HG group than in the control group (11.6 vs. 18.5 days, p = 0.1582; 30.8 vs. 47.4 days, p = 0.1861, respectively). Conclusions: The use of HG during PPP did not reduce hemorrhage-induced mortality, but did reduce the need for additional packed RBC transfusions in patients with hemodynamic instability due to severe pelvic fractures.
AB - Introduction: We evaluated the effectiveness of kaolin-impregnated hemostatic gauze use in preperitoneal pelvic packing (PPP) for patients with hemodynamic instability due to severe pelvic fractures. Materials and methods: Between May 2014 and October 2018, 53 of 75 patients who underwent PPP due to hemodynamic instability induced by pelvic fracture were enrolled. Their medical records were prospectively collected and retrospectively analyzed. QuikClot combat gauze (hydrophilic gauze impregnated with kaolin) and general surgical tape were used in 21 patients, while general surgical tape was used in the remaining 32 patients. Results: As there were differences in the characteristics of patients between the hemostatic gauze (HG) group and control group, propensity score matching (PSM) was performed to adjust for age, sex, and lactate levels. After PSM, the clinical characteristics between the two groups became similar. There were no differences in the rates of mortality and hemorrhageinduced mortality between the two groups. However, the packed red blood cell (RBC) requirement for an additional 12 hours in the HG group was significantly lower than that in the control group (4.1 ± 3.5 vs. 7.6 ± 6.1 units, p = 0.035). The lengths of intensive care unit and hospital stays tended to be shorter in the HG group than in the control group (11.6 vs. 18.5 days, p = 0.1582; 30.8 vs. 47.4 days, p = 0.1861, respectively). Conclusions: The use of HG during PPP did not reduce hemorrhage-induced mortality, but did reduce the need for additional packed RBC transfusions in patients with hemodynamic instability due to severe pelvic fractures.
UR - http://www.scopus.com/inward/record.url?scp=85088679073&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85088679073&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0236645
DO - 10.1371/journal.pone.0236645
M3 - Article
C2 - 32706824
AN - SCOPUS:85088679073
SN - 1932-6203
VL - 15
JO - PLoS One
JF - PLoS One
IS - 7 July
M1 - e0236645
ER -