Effects of placement angle and direction of orthopedic force application on the stability of orthodontic miniscrews

Jihye Lee, Ji Young Kim, Yoon Jeong Choi, Kyungho Kim, Chooryung Judi Chung

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Objectives: To evaluate the influence of placement angle and direction of orthopedic force application on the stability of miniscrews. Materials and Methods: Finite element analysis was performed using miniscrews inserted into supporting bone at angles of 90°, 60°, and 30° (P90°, P60°, and P30°). An orthopedic heavy force of 800 gf was applied to the heads of the miniscrews in four upward (U0°, U30°, U60°, U90°) or lateral (L0°, L30°, L60°, L90°) directions. In addition, pull-out strength of the miniscrews was measured with various force directions and cortical bone thicknesses. Results: Miniscrews with a placement angle of 30° (P30°) and 60° (P60°) showed a significant increase in maximum von Mises stress following the increase in lateral force vectors (U30°, U60°, U90°) compared to those with a placement angle of 90° (P90°). In accordance, the pull-out strength was higher with the axial upward force when compared to the upward force with lateral vectors. Maximum von Mises stress and displacement of the miniscrew increased as the angle of lateral force increased (L30°, L60°, L90°). However, a more dramatic increase in maximum von Mises stress was noted in P30° than in P60° and P90°. Conclusion: Placement of the miniscrew perpendicular to the cortical bone is advantageous in terms of biomechanical stability. Placement angles of less than 60° can reduce the stability of miniscrews when orthopedic forces are applied in various directions.

Original languageEnglish
Pages (from-to)667-673
Number of pages7
JournalAngle Orthodontist
Volume83
Issue number4
DOIs
Publication statusPublished - 2013 Jul 1

Fingerprint

Orthodontics
Orthopedics
L 30
Finite Element Analysis
Head
Bone and Bones
Direction compound
Cortical Bone

All Science Journal Classification (ASJC) codes

  • Orthodontics

Cite this

@article{0d09204214e64296a2ac16db1db7db40,
title = "Effects of placement angle and direction of orthopedic force application on the stability of orthodontic miniscrews",
abstract = "Objectives: To evaluate the influence of placement angle and direction of orthopedic force application on the stability of miniscrews. Materials and Methods: Finite element analysis was performed using miniscrews inserted into supporting bone at angles of 90°, 60°, and 30° (P90°, P60°, and P30°). An orthopedic heavy force of 800 gf was applied to the heads of the miniscrews in four upward (U0°, U30°, U60°, U90°) or lateral (L0°, L30°, L60°, L90°) directions. In addition, pull-out strength of the miniscrews was measured with various force directions and cortical bone thicknesses. Results: Miniscrews with a placement angle of 30° (P30°) and 60° (P60°) showed a significant increase in maximum von Mises stress following the increase in lateral force vectors (U30°, U60°, U90°) compared to those with a placement angle of 90° (P90°). In accordance, the pull-out strength was higher with the axial upward force when compared to the upward force with lateral vectors. Maximum von Mises stress and displacement of the miniscrew increased as the angle of lateral force increased (L30°, L60°, L90°). However, a more dramatic increase in maximum von Mises stress was noted in P30° than in P60° and P90°. Conclusion: Placement of the miniscrew perpendicular to the cortical bone is advantageous in terms of biomechanical stability. Placement angles of less than 60° can reduce the stability of miniscrews when orthopedic forces are applied in various directions.",
author = "Jihye Lee and Kim, {Ji Young} and Choi, {Yoon Jeong} and Kyungho Kim and Chung, {Chooryung Judi}",
year = "2013",
month = "7",
day = "1",
doi = "10.2319/090112-703.1",
language = "English",
volume = "83",
pages = "667--673",
journal = "Angle Orthodontist",
issn = "0003-3219",
publisher = "E H Angle Orthodontists Research & Education Foundation, Inc.",
number = "4",

}

Effects of placement angle and direction of orthopedic force application on the stability of orthodontic miniscrews. / Lee, Jihye; Kim, Ji Young; Choi, Yoon Jeong; Kim, Kyungho; Chung, Chooryung Judi.

In: Angle Orthodontist, Vol. 83, No. 4, 01.07.2013, p. 667-673.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Effects of placement angle and direction of orthopedic force application on the stability of orthodontic miniscrews

AU - Lee, Jihye

AU - Kim, Ji Young

AU - Choi, Yoon Jeong

AU - Kim, Kyungho

AU - Chung, Chooryung Judi

PY - 2013/7/1

Y1 - 2013/7/1

N2 - Objectives: To evaluate the influence of placement angle and direction of orthopedic force application on the stability of miniscrews. Materials and Methods: Finite element analysis was performed using miniscrews inserted into supporting bone at angles of 90°, 60°, and 30° (P90°, P60°, and P30°). An orthopedic heavy force of 800 gf was applied to the heads of the miniscrews in four upward (U0°, U30°, U60°, U90°) or lateral (L0°, L30°, L60°, L90°) directions. In addition, pull-out strength of the miniscrews was measured with various force directions and cortical bone thicknesses. Results: Miniscrews with a placement angle of 30° (P30°) and 60° (P60°) showed a significant increase in maximum von Mises stress following the increase in lateral force vectors (U30°, U60°, U90°) compared to those with a placement angle of 90° (P90°). In accordance, the pull-out strength was higher with the axial upward force when compared to the upward force with lateral vectors. Maximum von Mises stress and displacement of the miniscrew increased as the angle of lateral force increased (L30°, L60°, L90°). However, a more dramatic increase in maximum von Mises stress was noted in P30° than in P60° and P90°. Conclusion: Placement of the miniscrew perpendicular to the cortical bone is advantageous in terms of biomechanical stability. Placement angles of less than 60° can reduce the stability of miniscrews when orthopedic forces are applied in various directions.

AB - Objectives: To evaluate the influence of placement angle and direction of orthopedic force application on the stability of miniscrews. Materials and Methods: Finite element analysis was performed using miniscrews inserted into supporting bone at angles of 90°, 60°, and 30° (P90°, P60°, and P30°). An orthopedic heavy force of 800 gf was applied to the heads of the miniscrews in four upward (U0°, U30°, U60°, U90°) or lateral (L0°, L30°, L60°, L90°) directions. In addition, pull-out strength of the miniscrews was measured with various force directions and cortical bone thicknesses. Results: Miniscrews with a placement angle of 30° (P30°) and 60° (P60°) showed a significant increase in maximum von Mises stress following the increase in lateral force vectors (U30°, U60°, U90°) compared to those with a placement angle of 90° (P90°). In accordance, the pull-out strength was higher with the axial upward force when compared to the upward force with lateral vectors. Maximum von Mises stress and displacement of the miniscrew increased as the angle of lateral force increased (L30°, L60°, L90°). However, a more dramatic increase in maximum von Mises stress was noted in P30° than in P60° and P90°. Conclusion: Placement of the miniscrew perpendicular to the cortical bone is advantageous in terms of biomechanical stability. Placement angles of less than 60° can reduce the stability of miniscrews when orthopedic forces are applied in various directions.

UR - http://www.scopus.com/inward/record.url?scp=84881076705&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84881076705&partnerID=8YFLogxK

U2 - 10.2319/090112-703.1

DO - 10.2319/090112-703.1

M3 - Article

VL - 83

SP - 667

EP - 673

JO - Angle Orthodontist

JF - Angle Orthodontist

SN - 0003-3219

IS - 4

ER -