EIT-based fabric pressure sensing

A. Yao, C. L. Yang, J. K. Seo, M. Soleimani

Research output: Contribution to journalArticle

23 Citations (Scopus)

Abstract

This paper presents EIT-based fabric sensors that aim to provide a pressure mapping using the current carrying and voltage sensing electrodes attached to the boundary of the fabric patch. Pressure-induced shape change over the sensor area makes a change in the conductivity distribution which can be conveyed to the change of boundary current-voltage data. This boundary data is obtained through electrode measurements in EIT system. The corresponding inverse problem is to reconstruct the pressure and deformation map from the relationship between the applied current and the measured voltage on the fabric boundary. Taking advantage of EIT in providing dynamical images of conductivity changes due to pressure induced shape change, the pressure map can be estimated. In this paper, the EIT-based fabric sensor was presented for circular and rectangular sensor geometry. A stretch sensitive fabric was used in circular sensor with 16 electrodes and a pressure sensitive fabric was used in a rectangular sensor with 32 electrodes. A preliminary human test was carried out with the rectangular sensor for foot pressure mapping showing promising results.

Original languageEnglish
Article number405325
JournalComputational and Mathematical Methods in Medicine
Volume2013
DOIs
Publication statusPublished - 2013 Apr 5

Fingerprint

Sensing
Pressure
Sensor
Sensors
Electrode
Electrodes
Voltage
Conductivity
Electric potential
Stretch
Inverse problems
Patch
Foot
Inverse Problem
Geometry

All Science Journal Classification (ASJC) codes

  • Medicine(all)
  • Modelling and Simulation
  • Immunology and Microbiology(all)
  • Biochemistry, Genetics and Molecular Biology(all)
  • Applied Mathematics

Cite this

Yao, A. ; Yang, C. L. ; Seo, J. K. ; Soleimani, M. / EIT-based fabric pressure sensing. In: Computational and Mathematical Methods in Medicine. 2013 ; Vol. 2013.
@article{1722af5d85a7467fbcf7237fdaa13fc9,
title = "EIT-based fabric pressure sensing",
abstract = "This paper presents EIT-based fabric sensors that aim to provide a pressure mapping using the current carrying and voltage sensing electrodes attached to the boundary of the fabric patch. Pressure-induced shape change over the sensor area makes a change in the conductivity distribution which can be conveyed to the change of boundary current-voltage data. This boundary data is obtained through electrode measurements in EIT system. The corresponding inverse problem is to reconstruct the pressure and deformation map from the relationship between the applied current and the measured voltage on the fabric boundary. Taking advantage of EIT in providing dynamical images of conductivity changes due to pressure induced shape change, the pressure map can be estimated. In this paper, the EIT-based fabric sensor was presented for circular and rectangular sensor geometry. A stretch sensitive fabric was used in circular sensor with 16 electrodes and a pressure sensitive fabric was used in a rectangular sensor with 32 electrodes. A preliminary human test was carried out with the rectangular sensor for foot pressure mapping showing promising results.",
author = "A. Yao and Yang, {C. L.} and Seo, {J. K.} and M. Soleimani",
year = "2013",
month = "4",
day = "5",
doi = "10.1155/2013/405325",
language = "English",
volume = "2013",
journal = "Computational and Mathematical Methods in Medicine",
issn = "1748-670X",
publisher = "Hindawi Publishing Corporation",

}

EIT-based fabric pressure sensing. / Yao, A.; Yang, C. L.; Seo, J. K.; Soleimani, M.

In: Computational and Mathematical Methods in Medicine, Vol. 2013, 405325, 05.04.2013.

Research output: Contribution to journalArticle

TY - JOUR

T1 - EIT-based fabric pressure sensing

AU - Yao, A.

AU - Yang, C. L.

AU - Seo, J. K.

AU - Soleimani, M.

PY - 2013/4/5

Y1 - 2013/4/5

N2 - This paper presents EIT-based fabric sensors that aim to provide a pressure mapping using the current carrying and voltage sensing electrodes attached to the boundary of the fabric patch. Pressure-induced shape change over the sensor area makes a change in the conductivity distribution which can be conveyed to the change of boundary current-voltage data. This boundary data is obtained through electrode measurements in EIT system. The corresponding inverse problem is to reconstruct the pressure and deformation map from the relationship between the applied current and the measured voltage on the fabric boundary. Taking advantage of EIT in providing dynamical images of conductivity changes due to pressure induced shape change, the pressure map can be estimated. In this paper, the EIT-based fabric sensor was presented for circular and rectangular sensor geometry. A stretch sensitive fabric was used in circular sensor with 16 electrodes and a pressure sensitive fabric was used in a rectangular sensor with 32 electrodes. A preliminary human test was carried out with the rectangular sensor for foot pressure mapping showing promising results.

AB - This paper presents EIT-based fabric sensors that aim to provide a pressure mapping using the current carrying and voltage sensing electrodes attached to the boundary of the fabric patch. Pressure-induced shape change over the sensor area makes a change in the conductivity distribution which can be conveyed to the change of boundary current-voltage data. This boundary data is obtained through electrode measurements in EIT system. The corresponding inverse problem is to reconstruct the pressure and deformation map from the relationship between the applied current and the measured voltage on the fabric boundary. Taking advantage of EIT in providing dynamical images of conductivity changes due to pressure induced shape change, the pressure map can be estimated. In this paper, the EIT-based fabric sensor was presented for circular and rectangular sensor geometry. A stretch sensitive fabric was used in circular sensor with 16 electrodes and a pressure sensitive fabric was used in a rectangular sensor with 32 electrodes. A preliminary human test was carried out with the rectangular sensor for foot pressure mapping showing promising results.

UR - http://www.scopus.com/inward/record.url?scp=84875657364&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84875657364&partnerID=8YFLogxK

U2 - 10.1155/2013/405325

DO - 10.1155/2013/405325

M3 - Article

C2 - 23533538

AN - SCOPUS:84875657364

VL - 2013

JO - Computational and Mathematical Methods in Medicine

JF - Computational and Mathematical Methods in Medicine

SN - 1748-670X

M1 - 405325

ER -