Elucidation of obstructive sleep apnoea related blood pressure surge using a novel continuous beat-to-beat blood pressure monitoring system

Younghoon Kwon, Martin Baruch, Patrick L. Stafford, Heather Bonner, Yeilim Cho, Sula Mazimba, Jeongok G. Logan, Daichi Shimbo, Sung Ha Park, Gen Min Lin, Ali Azarbarzin, David A. Calhoun, Richard Berry, Robert M. Carey

Research output: Contribution to journalArticlepeer-review

Abstract

Background:Obstructive sleep apnoea (OSA) episode related blood pressure (BP) surge may mediate the association of OSA with cardiovascular disease. However, BP is not measured during a clinical sleep study.Method:We tested the feasibility of incorporating the Caretaker physiological monitor, which utilizes a novel continuous beat-to-beat (b-b) BP monitoring technology, into polysomnography (PSG) and aimed to characterize BP surges related to obstructive respiratory events. B-b BP was concurrently collected and merged with PSG data on a posthoc basis. We compared BP surge between mean respiratory (apnoea, hypopnea and desaturation-alone events) and nonrespiratory events (spontaneous or leg movement-related arousals). We examined the association of the degree of oxygen desaturation with BP surge in a given respiratory event combining all events. A total of 17 consecutive patients (12 men, mean 52 years old, nine diagnostic and eight split-night PSGs) undergoing clinically indicated PSG were included after excluding one patient with poor signal quality due to excessive movement.Results:Caretaker was well tolerated. Mean respiratory BP surge ranged from 5 to 19 mmHg [Median (IQR) = 13.9 (9.5 - 16.2)]. Mean BP surge between the respiratory and nonrespiratory events was similar [13.8 (4.5) vs. 14.9 (5.3) mmHg, P = 0.13]. Accounting for the count distribution of desaturation/BP surge data pair events, there was a linear correlation between the degree of oxygen desaturation and BP surge (R = 0.57, P < 0.001). In eight patients undergoing split-night sleep studies, the number of BP surge events (≥10 mmHg/h) decreased during continuous positive airway pressure in all but one patient.Conclusion:We demonstrated highly variable OSA-related BP surge patterns using the Caretaker's b-b BP monitoring technology that has the potential to be integrated into sleep studies.

Original languageEnglish
Pages (from-to)520-527
Number of pages8
JournalJournal of hypertension
Volume40
Issue number3
DOIs
Publication statusPublished - 2022 Mar 1

Bibliographical note

Funding Information:
Y.K. was supported by NIH R21 HL140432.

Publisher Copyright:
© 2022 Lippincott Williams and Wilkins. All rights reserved.

All Science Journal Classification (ASJC) codes

  • Internal Medicine
  • Physiology
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Elucidation of obstructive sleep apnoea related blood pressure surge using a novel continuous beat-to-beat blood pressure monitoring system'. Together they form a unique fingerprint.

Cite this