Evaluation of stiffness changes in a high-rise building by measurements of lateral displacements using GPS technology

Se Woon Choi, Ill Soo Kim, Jae Hwan Park, Yousok Kim, Hong Gyoo Sohn, Hyo Seon Park

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

The outrigger truss system is one of the most frequently used lateral load resisting structural systems. However, little research has been reported on the effect of installation of outrigger trusses on improvement of lateral stiffness of a high-rise building through full-scale measurements. In this paper, stiffness changes of a high-rise building due to installation of outrigger trusses have been evaluated by measuring lateral displacements using a global positioning system (GPS). To confirm the error range of the GPS measurement system used in the full-scale measurement tests, the GPS displacement monitoring system is investigated through a free vibration test of the experimental model. Then, for the evaluation of lateral stiffness of a high-rise building under construction, the GPS displacement monitoring system is applied to measurements of lateral displacements of a 66-story high-rise building before and after installation of outrigger truss. The stiffness improvement of the building before and after the installation is confirmed through the changes of the natural frequencies and the ratios of the base shear forces to the roof displacements.

Original languageEnglish
Pages (from-to)15489-15503
Number of pages15
JournalSensors (Switzerland)
Volume13
Issue number11
DOIs
Publication statusPublished - 2013 Nov 13

Fingerprint

Trusses
Geographic Information Systems
Global Positioning System
Global positioning system
stiffness
Stiffness
installing
Technology
trusses
evaluation
Monitoring
Base Composition
range errors
vibration tests
Vibration
Roofs
roofs
free vibration
Natural frequencies
Theoretical Models

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry
  • Atomic and Molecular Physics, and Optics
  • Biochemistry
  • Electrical and Electronic Engineering

Cite this

@article{c2dd207f7432470f9d423072b8f528ce,
title = "Evaluation of stiffness changes in a high-rise building by measurements of lateral displacements using GPS technology",
abstract = "The outrigger truss system is one of the most frequently used lateral load resisting structural systems. However, little research has been reported on the effect of installation of outrigger trusses on improvement of lateral stiffness of a high-rise building through full-scale measurements. In this paper, stiffness changes of a high-rise building due to installation of outrigger trusses have been evaluated by measuring lateral displacements using a global positioning system (GPS). To confirm the error range of the GPS measurement system used in the full-scale measurement tests, the GPS displacement monitoring system is investigated through a free vibration test of the experimental model. Then, for the evaluation of lateral stiffness of a high-rise building under construction, the GPS displacement monitoring system is applied to measurements of lateral displacements of a 66-story high-rise building before and after installation of outrigger truss. The stiffness improvement of the building before and after the installation is confirmed through the changes of the natural frequencies and the ratios of the base shear forces to the roof displacements.",
author = "Choi, {Se Woon} and Kim, {Ill Soo} and Park, {Jae Hwan} and Yousok Kim and Sohn, {Hong Gyoo} and Park, {Hyo Seon}",
year = "2013",
month = "11",
day = "13",
doi = "10.3390/s131115489",
language = "English",
volume = "13",
pages = "15489--15503",
journal = "Sensors",
issn = "1424-3210",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "11",

}

Evaluation of stiffness changes in a high-rise building by measurements of lateral displacements using GPS technology. / Choi, Se Woon; Kim, Ill Soo; Park, Jae Hwan; Kim, Yousok; Sohn, Hong Gyoo; Park, Hyo Seon.

In: Sensors (Switzerland), Vol. 13, No. 11, 13.11.2013, p. 15489-15503.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Evaluation of stiffness changes in a high-rise building by measurements of lateral displacements using GPS technology

AU - Choi, Se Woon

AU - Kim, Ill Soo

AU - Park, Jae Hwan

AU - Kim, Yousok

AU - Sohn, Hong Gyoo

AU - Park, Hyo Seon

PY - 2013/11/13

Y1 - 2013/11/13

N2 - The outrigger truss system is one of the most frequently used lateral load resisting structural systems. However, little research has been reported on the effect of installation of outrigger trusses on improvement of lateral stiffness of a high-rise building through full-scale measurements. In this paper, stiffness changes of a high-rise building due to installation of outrigger trusses have been evaluated by measuring lateral displacements using a global positioning system (GPS). To confirm the error range of the GPS measurement system used in the full-scale measurement tests, the GPS displacement monitoring system is investigated through a free vibration test of the experimental model. Then, for the evaluation of lateral stiffness of a high-rise building under construction, the GPS displacement monitoring system is applied to measurements of lateral displacements of a 66-story high-rise building before and after installation of outrigger truss. The stiffness improvement of the building before and after the installation is confirmed through the changes of the natural frequencies and the ratios of the base shear forces to the roof displacements.

AB - The outrigger truss system is one of the most frequently used lateral load resisting structural systems. However, little research has been reported on the effect of installation of outrigger trusses on improvement of lateral stiffness of a high-rise building through full-scale measurements. In this paper, stiffness changes of a high-rise building due to installation of outrigger trusses have been evaluated by measuring lateral displacements using a global positioning system (GPS). To confirm the error range of the GPS measurement system used in the full-scale measurement tests, the GPS displacement monitoring system is investigated through a free vibration test of the experimental model. Then, for the evaluation of lateral stiffness of a high-rise building under construction, the GPS displacement monitoring system is applied to measurements of lateral displacements of a 66-story high-rise building before and after installation of outrigger truss. The stiffness improvement of the building before and after the installation is confirmed through the changes of the natural frequencies and the ratios of the base shear forces to the roof displacements.

UR - http://www.scopus.com/inward/record.url?scp=84887715324&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84887715324&partnerID=8YFLogxK

U2 - 10.3390/s131115489

DO - 10.3390/s131115489

M3 - Article

VL - 13

SP - 15489

EP - 15503

JO - Sensors

JF - Sensors

SN - 1424-3210

IS - 11

ER -