Abstract

Purpose. A new automated Cobas u 701 microscopy analyser for urine sediment examination was introduced. The aim of this study was to evaluate the analyser in comparison with urine culture in screening for urinary tract infection (UTI). Methodology. A total of 852 urine specimens submitted for culture were included in this study. Urine sediment examination was performed using the Cobas u 701 microscopy analyser. The results of the bacteria (BAC) and yeast (YEA) analyses were compared with the results from urine culture as a method for UTI screening. In addition, we compared the BAC results with white blood cells (WBCs) and leukocyte and nitrite measurement in the Cobas u 601 system. Results. Of the 852 urine specimens, 16.1% (N=137) were positive by urine culture, yielding 130 bacteria from 124 specimens and 14 yeasts from 14 specimens. The Cobas u 701 microscopy analyser provided no result for 52 specimens because of their high turbidity. The sensitivity, specificity, positive predictive value and negative predictive value were 85.8, 69.4, 33.1 and 96.5%, respectively. For YEA, these figures were 100, 91.9, 15.8 and 100%, respectively. The areas under the curve for BAC and WBCs were 0.827 [95% confidence interval (CI) 0.799, 0.852] and 0.727 (95% CI 0.695, 0.757), respectively. The sensitivity of the leukocyte and nitrite was 63.5 and 54.6%, respectively. Conclusion. The Cobas u 701 microscopy analyser showed good diagnostic performance. It can be used for rapid screening for UTI and can reduce the number of cultures required.

Original languageEnglish
Pages (from-to)1110-1113
Number of pages4
JournalJournal of Medical Microbiology
Volume66
Issue number8
DOIs
Publication statusPublished - 2017 Aug 1

Fingerprint

Urinary Tract Infections
Microscopy
Urine
Leukocytes
Bacteria
Yeasts
Nitrites
Confidence Intervals
Area Under Curve
Sensitivity and Specificity

All Science Journal Classification (ASJC) codes

  • Microbiology
  • Microbiology (medical)

Cite this

Kim, Si Hyun ; Song, Sae Am ; Urm, Sang Hwa ; Kook, Joong Ki ; Kim, Hye Ran ; Yong, DongEun ; Choi, JunYong ; Shin, Jeong Hwan. / Evaluation of the cobas U 701 microscopy analyser compared with urine culture in screening for urinary tract infection. In: Journal of Medical Microbiology. 2017 ; Vol. 66, No. 8. pp. 1110-1113.
@article{74b10a632199400e8926cc9a603d974f,
title = "Evaluation of the cobas U 701 microscopy analyser compared with urine culture in screening for urinary tract infection",
abstract = "Purpose. A new automated Cobas u 701 microscopy analyser for urine sediment examination was introduced. The aim of this study was to evaluate the analyser in comparison with urine culture in screening for urinary tract infection (UTI). Methodology. A total of 852 urine specimens submitted for culture were included in this study. Urine sediment examination was performed using the Cobas u 701 microscopy analyser. The results of the bacteria (BAC) and yeast (YEA) analyses were compared with the results from urine culture as a method for UTI screening. In addition, we compared the BAC results with white blood cells (WBCs) and leukocyte and nitrite measurement in the Cobas u 601 system. Results. Of the 852 urine specimens, 16.1{\%} (N=137) were positive by urine culture, yielding 130 bacteria from 124 specimens and 14 yeasts from 14 specimens. The Cobas u 701 microscopy analyser provided no result for 52 specimens because of their high turbidity. The sensitivity, specificity, positive predictive value and negative predictive value were 85.8, 69.4, 33.1 and 96.5{\%}, respectively. For YEA, these figures were 100, 91.9, 15.8 and 100{\%}, respectively. The areas under the curve for BAC and WBCs were 0.827 [95{\%} confidence interval (CI) 0.799, 0.852] and 0.727 (95{\%} CI 0.695, 0.757), respectively. The sensitivity of the leukocyte and nitrite was 63.5 and 54.6{\%}, respectively. Conclusion. The Cobas u 701 microscopy analyser showed good diagnostic performance. It can be used for rapid screening for UTI and can reduce the number of cultures required.",
author = "Kim, {Si Hyun} and Song, {Sae Am} and Urm, {Sang Hwa} and Kook, {Joong Ki} and Kim, {Hye Ran} and DongEun Yong and JunYong Choi and Shin, {Jeong Hwan}",
year = "2017",
month = "8",
day = "1",
doi = "10.1099/jmm.0.000553",
language = "English",
volume = "66",
pages = "1110--1113",
journal = "Journal of Medical Microbiology",
issn = "0022-2615",
publisher = "Society for General Microbiology",
number = "8",

}

Evaluation of the cobas U 701 microscopy analyser compared with urine culture in screening for urinary tract infection. / Kim, Si Hyun; Song, Sae Am; Urm, Sang Hwa; Kook, Joong Ki; Kim, Hye Ran; Yong, DongEun; Choi, JunYong; Shin, Jeong Hwan.

In: Journal of Medical Microbiology, Vol. 66, No. 8, 01.08.2017, p. 1110-1113.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Evaluation of the cobas U 701 microscopy analyser compared with urine culture in screening for urinary tract infection

AU - Kim, Si Hyun

AU - Song, Sae Am

AU - Urm, Sang Hwa

AU - Kook, Joong Ki

AU - Kim, Hye Ran

AU - Yong, DongEun

AU - Choi, JunYong

AU - Shin, Jeong Hwan

PY - 2017/8/1

Y1 - 2017/8/1

N2 - Purpose. A new automated Cobas u 701 microscopy analyser for urine sediment examination was introduced. The aim of this study was to evaluate the analyser in comparison with urine culture in screening for urinary tract infection (UTI). Methodology. A total of 852 urine specimens submitted for culture were included in this study. Urine sediment examination was performed using the Cobas u 701 microscopy analyser. The results of the bacteria (BAC) and yeast (YEA) analyses were compared with the results from urine culture as a method for UTI screening. In addition, we compared the BAC results with white blood cells (WBCs) and leukocyte and nitrite measurement in the Cobas u 601 system. Results. Of the 852 urine specimens, 16.1% (N=137) were positive by urine culture, yielding 130 bacteria from 124 specimens and 14 yeasts from 14 specimens. The Cobas u 701 microscopy analyser provided no result for 52 specimens because of their high turbidity. The sensitivity, specificity, positive predictive value and negative predictive value were 85.8, 69.4, 33.1 and 96.5%, respectively. For YEA, these figures were 100, 91.9, 15.8 and 100%, respectively. The areas under the curve for BAC and WBCs were 0.827 [95% confidence interval (CI) 0.799, 0.852] and 0.727 (95% CI 0.695, 0.757), respectively. The sensitivity of the leukocyte and nitrite was 63.5 and 54.6%, respectively. Conclusion. The Cobas u 701 microscopy analyser showed good diagnostic performance. It can be used for rapid screening for UTI and can reduce the number of cultures required.

AB - Purpose. A new automated Cobas u 701 microscopy analyser for urine sediment examination was introduced. The aim of this study was to evaluate the analyser in comparison with urine culture in screening for urinary tract infection (UTI). Methodology. A total of 852 urine specimens submitted for culture were included in this study. Urine sediment examination was performed using the Cobas u 701 microscopy analyser. The results of the bacteria (BAC) and yeast (YEA) analyses were compared with the results from urine culture as a method for UTI screening. In addition, we compared the BAC results with white blood cells (WBCs) and leukocyte and nitrite measurement in the Cobas u 601 system. Results. Of the 852 urine specimens, 16.1% (N=137) were positive by urine culture, yielding 130 bacteria from 124 specimens and 14 yeasts from 14 specimens. The Cobas u 701 microscopy analyser provided no result for 52 specimens because of their high turbidity. The sensitivity, specificity, positive predictive value and negative predictive value were 85.8, 69.4, 33.1 and 96.5%, respectively. For YEA, these figures were 100, 91.9, 15.8 and 100%, respectively. The areas under the curve for BAC and WBCs were 0.827 [95% confidence interval (CI) 0.799, 0.852] and 0.727 (95% CI 0.695, 0.757), respectively. The sensitivity of the leukocyte and nitrite was 63.5 and 54.6%, respectively. Conclusion. The Cobas u 701 microscopy analyser showed good diagnostic performance. It can be used for rapid screening for UTI and can reduce the number of cultures required.

UR - http://www.scopus.com/inward/record.url?scp=85029480785&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85029480785&partnerID=8YFLogxK

U2 - 10.1099/jmm.0.000553

DO - 10.1099/jmm.0.000553

M3 - Article

AN - SCOPUS:85029480785

VL - 66

SP - 1110

EP - 1113

JO - Journal of Medical Microbiology

JF - Journal of Medical Microbiology

SN - 0022-2615

IS - 8

ER -