Experimental evaluation of internal blast resistance behavior of reinforced concrete tubular structures under internal blast loading

Ji Hun Choi, Seung Jai Choi, Tae Hee Lee, Jang Ho Jay Kim

Research output: Contribution to journalArticle

Abstract

Since the Sept. 11 of 2001 terrorist attack on world trade center, social anxiety about extreme disasters heightened. In Korea, a country with extreme military aggression located area in the world, South Korea is always exposed to explosion disasters. In order to combat these problems, it is necessary to study extreme loading scenarios based on the concept of protection and disaster prevention of social infrastructures. For the blast load, the various researches were performed in the past. However, the study results on the internal blast loaded structural behavior are not open to public. In this study, internal blast tests were carried out on reinforced concrete (RC) tubular members to evaluate the internal blast resistance capacity. The specimens were designed as RC tubular structure with dimensions of external diameter of 2,700 mm, internal diameter of 2,000 mm, a wall thickness of 350 mm and a length of 3,600 mm. The blast load test was conducted using 15.88, 20.41, and 24.95 kg (e.g., equivalent to 35, 45, and 55 lbs) of ANFO charge installed at the center of the tube (e.g., 1,000 mm standoff distance), the structure behavior according to the explosive charge weight was evaluated. The data acquisitions included incident pressure, reflected pressure, impulse, deflection, strain, and acceleration. Through the experimental evaluation, the structural behavior according to internal blast loading scenario can be analyzed accurately, which can be effectively used for protection and extreme loading research area.

Original languageEnglish
Pages (from-to)319-330
Number of pages12
JournalJournal of the Korea Concrete Institute
Volume31
Issue number4
DOIs
Publication statusPublished - 2019 Aug

Fingerprint

Blast resistance
Reinforced concrete
Disasters
Disaster prevention
Explosions
Data acquisition

All Science Journal Classification (ASJC) codes

  • Civil and Structural Engineering
  • Building and Construction
  • Materials Science (miscellaneous)
  • Mechanics of Materials

Cite this

@article{f3aec64726fd42b6964ebbeb299bb603,
title = "Experimental evaluation of internal blast resistance behavior of reinforced concrete tubular structures under internal blast loading",
abstract = "Since the Sept. 11 of 2001 terrorist attack on world trade center, social anxiety about extreme disasters heightened. In Korea, a country with extreme military aggression located area in the world, South Korea is always exposed to explosion disasters. In order to combat these problems, it is necessary to study extreme loading scenarios based on the concept of protection and disaster prevention of social infrastructures. For the blast load, the various researches were performed in the past. However, the study results on the internal blast loaded structural behavior are not open to public. In this study, internal blast tests were carried out on reinforced concrete (RC) tubular members to evaluate the internal blast resistance capacity. The specimens were designed as RC tubular structure with dimensions of external diameter of 2,700 mm, internal diameter of 2,000 mm, a wall thickness of 350 mm and a length of 3,600 mm. The blast load test was conducted using 15.88, 20.41, and 24.95 kg (e.g., equivalent to 35, 45, and 55 lbs) of ANFO charge installed at the center of the tube (e.g., 1,000 mm standoff distance), the structure behavior according to the explosive charge weight was evaluated. The data acquisitions included incident pressure, reflected pressure, impulse, deflection, strain, and acceleration. Through the experimental evaluation, the structural behavior according to internal blast loading scenario can be analyzed accurately, which can be effectively used for protection and extreme loading research area.",
author = "Choi, {Ji Hun} and Choi, {Seung Jai} and Lee, {Tae Hee} and Kim, {Jang Ho Jay}",
year = "2019",
month = "8",
doi = "10.4334/JKCI.2019.31.4.319",
language = "English",
volume = "31",
pages = "319--330",
journal = "Journal of the Korea Concrete Institute",
issn = "1229-5515",
publisher = "Korea Concrete Institute",
number = "4",

}

Experimental evaluation of internal blast resistance behavior of reinforced concrete tubular structures under internal blast loading. / Choi, Ji Hun; Choi, Seung Jai; Lee, Tae Hee; Kim, Jang Ho Jay.

In: Journal of the Korea Concrete Institute, Vol. 31, No. 4, 08.2019, p. 319-330.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Experimental evaluation of internal blast resistance behavior of reinforced concrete tubular structures under internal blast loading

AU - Choi, Ji Hun

AU - Choi, Seung Jai

AU - Lee, Tae Hee

AU - Kim, Jang Ho Jay

PY - 2019/8

Y1 - 2019/8

N2 - Since the Sept. 11 of 2001 terrorist attack on world trade center, social anxiety about extreme disasters heightened. In Korea, a country with extreme military aggression located area in the world, South Korea is always exposed to explosion disasters. In order to combat these problems, it is necessary to study extreme loading scenarios based on the concept of protection and disaster prevention of social infrastructures. For the blast load, the various researches were performed in the past. However, the study results on the internal blast loaded structural behavior are not open to public. In this study, internal blast tests were carried out on reinforced concrete (RC) tubular members to evaluate the internal blast resistance capacity. The specimens were designed as RC tubular structure with dimensions of external diameter of 2,700 mm, internal diameter of 2,000 mm, a wall thickness of 350 mm and a length of 3,600 mm. The blast load test was conducted using 15.88, 20.41, and 24.95 kg (e.g., equivalent to 35, 45, and 55 lbs) of ANFO charge installed at the center of the tube (e.g., 1,000 mm standoff distance), the structure behavior according to the explosive charge weight was evaluated. The data acquisitions included incident pressure, reflected pressure, impulse, deflection, strain, and acceleration. Through the experimental evaluation, the structural behavior according to internal blast loading scenario can be analyzed accurately, which can be effectively used for protection and extreme loading research area.

AB - Since the Sept. 11 of 2001 terrorist attack on world trade center, social anxiety about extreme disasters heightened. In Korea, a country with extreme military aggression located area in the world, South Korea is always exposed to explosion disasters. In order to combat these problems, it is necessary to study extreme loading scenarios based on the concept of protection and disaster prevention of social infrastructures. For the blast load, the various researches were performed in the past. However, the study results on the internal blast loaded structural behavior are not open to public. In this study, internal blast tests were carried out on reinforced concrete (RC) tubular members to evaluate the internal blast resistance capacity. The specimens were designed as RC tubular structure with dimensions of external diameter of 2,700 mm, internal diameter of 2,000 mm, a wall thickness of 350 mm and a length of 3,600 mm. The blast load test was conducted using 15.88, 20.41, and 24.95 kg (e.g., equivalent to 35, 45, and 55 lbs) of ANFO charge installed at the center of the tube (e.g., 1,000 mm standoff distance), the structure behavior according to the explosive charge weight was evaluated. The data acquisitions included incident pressure, reflected pressure, impulse, deflection, strain, and acceleration. Through the experimental evaluation, the structural behavior according to internal blast loading scenario can be analyzed accurately, which can be effectively used for protection and extreme loading research area.

UR - http://www.scopus.com/inward/record.url?scp=85073280058&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85073280058&partnerID=8YFLogxK

U2 - 10.4334/JKCI.2019.31.4.319

DO - 10.4334/JKCI.2019.31.4.319

M3 - Article

AN - SCOPUS:85073280058

VL - 31

SP - 319

EP - 330

JO - Journal of the Korea Concrete Institute

JF - Journal of the Korea Concrete Institute

SN - 1229-5515

IS - 4

ER -