FACS-based immunoassay of troponin-I using E. coli cells with autodisplayed Z-domains

Min Park, Ji Hong Bong, Young Wook Chang, Gu Yoo, Joachim Jose, Min Jung Kang, Jae Chul Pyun

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Fluorescence-activated cell sorter (FACS)-based immunoassays using E. coli cells with autodisplayed Z-domains were performed to (1) improve the sensitivity of the immunoassay through orientation control of antibodies with autodisplayed Z-domains and (2) minimize the required amount of analyte by using FACS to measure the fluorescent signal from individual E. coli cells. The expression (autodisplay) of Z-domains on the outer membrane of E. coli was confirmed by fluorescence image analysis, and the homogeneous distribution of autodisplayed Z-domains was presented by SEM image analysis after treatment with antibodies labeled with gold nanoparticles (diameter of 15 nm). As FACS measures the fluorescent signal from individual E. coli cells, the optimal FACS parameters for the effective detection of fluorescently labeled E. coli cells were determined, and the minimum amount of analyte required for the E. coli cell-based immunoassay was identified using two model immunoassay configurations. Finally, the medical diagnosis of heart infarction with a biomarker called troponin-I using the E. coli cell-based immunoassay with FACS analysis was demonstrated.

Original languageEnglish
Pages (from-to)1700-1708
Number of pages9
JournalAnalytical Methods
Volume6
Issue number6
DOIs
Publication statusPublished - 2014 Mar 21

Fingerprint

Troponin I
Escherichia coli
Fluorescence
Antibodies
Image analysis
Biomarkers
Gold
Nanoparticles
Membranes
Scanning electron microscopy

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry
  • Chemical Engineering(all)
  • Engineering(all)

Cite this

Park, Min ; Bong, Ji Hong ; Chang, Young Wook ; Yoo, Gu ; Jose, Joachim ; Kang, Min Jung ; Pyun, Jae Chul. / FACS-based immunoassay of troponin-I using E. coli cells with autodisplayed Z-domains. In: Analytical Methods. 2014 ; Vol. 6, No. 6. pp. 1700-1708.
@article{a950ee4134a44dfd8b2638ec3d4f285e,
title = "FACS-based immunoassay of troponin-I using E. coli cells with autodisplayed Z-domains",
abstract = "Fluorescence-activated cell sorter (FACS)-based immunoassays using E. coli cells with autodisplayed Z-domains were performed to (1) improve the sensitivity of the immunoassay through orientation control of antibodies with autodisplayed Z-domains and (2) minimize the required amount of analyte by using FACS to measure the fluorescent signal from individual E. coli cells. The expression (autodisplay) of Z-domains on the outer membrane of E. coli was confirmed by fluorescence image analysis, and the homogeneous distribution of autodisplayed Z-domains was presented by SEM image analysis after treatment with antibodies labeled with gold nanoparticles (diameter of 15 nm). As FACS measures the fluorescent signal from individual E. coli cells, the optimal FACS parameters for the effective detection of fluorescently labeled E. coli cells were determined, and the minimum amount of analyte required for the E. coli cell-based immunoassay was identified using two model immunoassay configurations. Finally, the medical diagnosis of heart infarction with a biomarker called troponin-I using the E. coli cell-based immunoassay with FACS analysis was demonstrated.",
author = "Min Park and Bong, {Ji Hong} and Chang, {Young Wook} and Gu Yoo and Joachim Jose and Kang, {Min Jung} and Pyun, {Jae Chul}",
year = "2014",
month = "3",
day = "21",
doi = "10.1039/c3ay42206b",
language = "English",
volume = "6",
pages = "1700--1708",
journal = "Analytical Methods",
issn = "1759-9660",
publisher = "Royal Society of Chemistry",
number = "6",

}

FACS-based immunoassay of troponin-I using E. coli cells with autodisplayed Z-domains. / Park, Min; Bong, Ji Hong; Chang, Young Wook; Yoo, Gu; Jose, Joachim; Kang, Min Jung; Pyun, Jae Chul.

In: Analytical Methods, Vol. 6, No. 6, 21.03.2014, p. 1700-1708.

Research output: Contribution to journalArticle

TY - JOUR

T1 - FACS-based immunoassay of troponin-I using E. coli cells with autodisplayed Z-domains

AU - Park, Min

AU - Bong, Ji Hong

AU - Chang, Young Wook

AU - Yoo, Gu

AU - Jose, Joachim

AU - Kang, Min Jung

AU - Pyun, Jae Chul

PY - 2014/3/21

Y1 - 2014/3/21

N2 - Fluorescence-activated cell sorter (FACS)-based immunoassays using E. coli cells with autodisplayed Z-domains were performed to (1) improve the sensitivity of the immunoassay through orientation control of antibodies with autodisplayed Z-domains and (2) minimize the required amount of analyte by using FACS to measure the fluorescent signal from individual E. coli cells. The expression (autodisplay) of Z-domains on the outer membrane of E. coli was confirmed by fluorescence image analysis, and the homogeneous distribution of autodisplayed Z-domains was presented by SEM image analysis after treatment with antibodies labeled with gold nanoparticles (diameter of 15 nm). As FACS measures the fluorescent signal from individual E. coli cells, the optimal FACS parameters for the effective detection of fluorescently labeled E. coli cells were determined, and the minimum amount of analyte required for the E. coli cell-based immunoassay was identified using two model immunoassay configurations. Finally, the medical diagnosis of heart infarction with a biomarker called troponin-I using the E. coli cell-based immunoassay with FACS analysis was demonstrated.

AB - Fluorescence-activated cell sorter (FACS)-based immunoassays using E. coli cells with autodisplayed Z-domains were performed to (1) improve the sensitivity of the immunoassay through orientation control of antibodies with autodisplayed Z-domains and (2) minimize the required amount of analyte by using FACS to measure the fluorescent signal from individual E. coli cells. The expression (autodisplay) of Z-domains on the outer membrane of E. coli was confirmed by fluorescence image analysis, and the homogeneous distribution of autodisplayed Z-domains was presented by SEM image analysis after treatment with antibodies labeled with gold nanoparticles (diameter of 15 nm). As FACS measures the fluorescent signal from individual E. coli cells, the optimal FACS parameters for the effective detection of fluorescently labeled E. coli cells were determined, and the minimum amount of analyte required for the E. coli cell-based immunoassay was identified using two model immunoassay configurations. Finally, the medical diagnosis of heart infarction with a biomarker called troponin-I using the E. coli cell-based immunoassay with FACS analysis was demonstrated.

UR - http://www.scopus.com/inward/record.url?scp=84896836358&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84896836358&partnerID=8YFLogxK

U2 - 10.1039/c3ay42206b

DO - 10.1039/c3ay42206b

M3 - Article

VL - 6

SP - 1700

EP - 1708

JO - Analytical Methods

JF - Analytical Methods

SN - 1759-9660

IS - 6

ER -