Flexible Non-Constrained RF Wrist Pulse Detection Sensor Based on Array Resonators

Yong Jun An, Byung Hyun Kim, Gi Ho Yun, Sung Woo Kim, Seung Bum Hong, Jong Gwan Yook

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

This paper presents the development of a non-contact, nonintrusive wrist pulse sensor based on the near-field variation of an array resonator. A compact resonator and its array were designed and fabricated on flexible substrate. The reflection coefficient of the resonator can vary as a function of the distance between the resonator and the walls of the major arteries, and the corresponding variation is utilized to obtain heart rate information at the wrist. To detect very weak pulse signals from the main arteries, a sensitivity enhancement technique was devised using a radio frequency (RF) array resonator. The sensor system was implemented with an RF switch to combine or select appropriate signals from the resonator element and was tested using the 2.4 GHz ISM band. The results demonstrated the sensor system's excellent performance in both sequential and simultaneous detection schemes. The measurement results showed that a heartbeat pulse can be detected from both radial and ulnar arteries via the array resonators. Considering the high sensitivity and characteristics, the proposed detection system can be utilized as a wearable, long-term health monitoring device.

Original languageEnglish
Article number7103364
Pages (from-to)300-308
Number of pages9
JournalIEEE Transactions on Biomedical Circuits and Systems
Volume10
Issue number2
DOIs
Publication statusPublished - 2016 Apr

Fingerprint

Resonators
Sensors
Switches
Health
Monitoring
Substrates

All Science Journal Classification (ASJC) codes

  • Biomedical Engineering
  • Electrical and Electronic Engineering

Cite this

An, Yong Jun ; Kim, Byung Hyun ; Yun, Gi Ho ; Kim, Sung Woo ; Hong, Seung Bum ; Yook, Jong Gwan. / Flexible Non-Constrained RF Wrist Pulse Detection Sensor Based on Array Resonators. In: IEEE Transactions on Biomedical Circuits and Systems. 2016 ; Vol. 10, No. 2. pp. 300-308.
@article{82ba77d06c824192b6999f942662e9d0,
title = "Flexible Non-Constrained RF Wrist Pulse Detection Sensor Based on Array Resonators",
abstract = "This paper presents the development of a non-contact, nonintrusive wrist pulse sensor based on the near-field variation of an array resonator. A compact resonator and its array were designed and fabricated on flexible substrate. The reflection coefficient of the resonator can vary as a function of the distance between the resonator and the walls of the major arteries, and the corresponding variation is utilized to obtain heart rate information at the wrist. To detect very weak pulse signals from the main arteries, a sensitivity enhancement technique was devised using a radio frequency (RF) array resonator. The sensor system was implemented with an RF switch to combine or select appropriate signals from the resonator element and was tested using the 2.4 GHz ISM band. The results demonstrated the sensor system's excellent performance in both sequential and simultaneous detection schemes. The measurement results showed that a heartbeat pulse can be detected from both radial and ulnar arteries via the array resonators. Considering the high sensitivity and characteristics, the proposed detection system can be utilized as a wearable, long-term health monitoring device.",
author = "An, {Yong Jun} and Kim, {Byung Hyun} and Yun, {Gi Ho} and Kim, {Sung Woo} and Hong, {Seung Bum} and Yook, {Jong Gwan}",
year = "2016",
month = "4",
doi = "10.1109/TBCAS.2015.2406776",
language = "English",
volume = "10",
pages = "300--308",
journal = "IEEE Transactions on Biomedical Circuits and Systems",
issn = "1932-4545",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "2",

}

Flexible Non-Constrained RF Wrist Pulse Detection Sensor Based on Array Resonators. / An, Yong Jun; Kim, Byung Hyun; Yun, Gi Ho; Kim, Sung Woo; Hong, Seung Bum; Yook, Jong Gwan.

In: IEEE Transactions on Biomedical Circuits and Systems, Vol. 10, No. 2, 7103364, 04.2016, p. 300-308.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Flexible Non-Constrained RF Wrist Pulse Detection Sensor Based on Array Resonators

AU - An, Yong Jun

AU - Kim, Byung Hyun

AU - Yun, Gi Ho

AU - Kim, Sung Woo

AU - Hong, Seung Bum

AU - Yook, Jong Gwan

PY - 2016/4

Y1 - 2016/4

N2 - This paper presents the development of a non-contact, nonintrusive wrist pulse sensor based on the near-field variation of an array resonator. A compact resonator and its array were designed and fabricated on flexible substrate. The reflection coefficient of the resonator can vary as a function of the distance between the resonator and the walls of the major arteries, and the corresponding variation is utilized to obtain heart rate information at the wrist. To detect very weak pulse signals from the main arteries, a sensitivity enhancement technique was devised using a radio frequency (RF) array resonator. The sensor system was implemented with an RF switch to combine or select appropriate signals from the resonator element and was tested using the 2.4 GHz ISM band. The results demonstrated the sensor system's excellent performance in both sequential and simultaneous detection schemes. The measurement results showed that a heartbeat pulse can be detected from both radial and ulnar arteries via the array resonators. Considering the high sensitivity and characteristics, the proposed detection system can be utilized as a wearable, long-term health monitoring device.

AB - This paper presents the development of a non-contact, nonintrusive wrist pulse sensor based on the near-field variation of an array resonator. A compact resonator and its array were designed and fabricated on flexible substrate. The reflection coefficient of the resonator can vary as a function of the distance between the resonator and the walls of the major arteries, and the corresponding variation is utilized to obtain heart rate information at the wrist. To detect very weak pulse signals from the main arteries, a sensitivity enhancement technique was devised using a radio frequency (RF) array resonator. The sensor system was implemented with an RF switch to combine or select appropriate signals from the resonator element and was tested using the 2.4 GHz ISM band. The results demonstrated the sensor system's excellent performance in both sequential and simultaneous detection schemes. The measurement results showed that a heartbeat pulse can be detected from both radial and ulnar arteries via the array resonators. Considering the high sensitivity and characteristics, the proposed detection system can be utilized as a wearable, long-term health monitoring device.

UR - http://www.scopus.com/inward/record.url?scp=84929008859&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84929008859&partnerID=8YFLogxK

U2 - 10.1109/TBCAS.2015.2406776

DO - 10.1109/TBCAS.2015.2406776

M3 - Article

C2 - 25966481

AN - SCOPUS:84929008859

VL - 10

SP - 300

EP - 308

JO - IEEE Transactions on Biomedical Circuits and Systems

JF - IEEE Transactions on Biomedical Circuits and Systems

SN - 1932-4545

IS - 2

M1 - 7103364

ER -