Hemodynamic effects of the geometric dimensions of graft vessels in Coronary Artery Bypass Graft models

Dongsoo Kim, Hyuck Moon Kwon, Byung Kwon Lee, Yangsoo Jang, Sang Ho Suh, Sang Shin Yoo, Hyun Seung Kim

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

The objectives of this investigation are to evaluate the rheologic properties in atherosclerotic disease treated with the various coronary artery bypass graft (CABG) models by numerical analysis, we used four different CABG models for the assessment of spatial fluctuation in wall shear stress, pressure variation and mass flow rate with Carreau model and Navier-Stokes equation. Wall shear stress was higher in a naturally tapered model (model 1) and a constant (non-tapered) diameter of the graft vessel the same as the distal LAD (model 4) than in others. Pressure variation along the native coronary artery and graft vessels was higher in a model 4, model 1 than in a reverse tapering model (model 2) and a constant diameter of the graft vessel the same as the proximal LAD (model 3). The mass flow rate of the distal part (kg/sec, mo) was the highest in model 3. This study suggests that in vitro spatial simulation following CABG revealed that small caliber or tapered graft vessels have adverse hemodynamic effects on the native and graft vessels. By this technique it is possible to simulate the optimal distribution of local hemodynamic variables in patients treated with CABG, also to minimize the degeneration of graft vessel.

Original languageEnglish
Pages (from-to)263-268
Number of pages6
JournalJournal of Korean Medical Science
Volume13
Issue number3
DOIs
Publication statusPublished - 1998 Jan 1

Fingerprint

Coronary Artery Bypass
Hemodynamics
Transplants
Pressure
Coronary Vessels

All Science Journal Classification (ASJC) codes

  • Medicine(all)

Cite this

Kim, Dongsoo ; Kwon, Hyuck Moon ; Lee, Byung Kwon ; Jang, Yangsoo ; Suh, Sang Ho ; Yoo, Sang Shin ; Kim, Hyun Seung. / Hemodynamic effects of the geometric dimensions of graft vessels in Coronary Artery Bypass Graft models. In: Journal of Korean Medical Science. 1998 ; Vol. 13, No. 3. pp. 263-268.
@article{63cf270a3779464e8f5098e4b677fff5,
title = "Hemodynamic effects of the geometric dimensions of graft vessels in Coronary Artery Bypass Graft models",
abstract = "The objectives of this investigation are to evaluate the rheologic properties in atherosclerotic disease treated with the various coronary artery bypass graft (CABG) models by numerical analysis, we used four different CABG models for the assessment of spatial fluctuation in wall shear stress, pressure variation and mass flow rate with Carreau model and Navier-Stokes equation. Wall shear stress was higher in a naturally tapered model (model 1) and a constant (non-tapered) diameter of the graft vessel the same as the distal LAD (model 4) than in others. Pressure variation along the native coronary artery and graft vessels was higher in a model 4, model 1 than in a reverse tapering model (model 2) and a constant diameter of the graft vessel the same as the proximal LAD (model 3). The mass flow rate of the distal part (kg/sec, mo) was the highest in model 3. This study suggests that in vitro spatial simulation following CABG revealed that small caliber or tapered graft vessels have adverse hemodynamic effects on the native and graft vessels. By this technique it is possible to simulate the optimal distribution of local hemodynamic variables in patients treated with CABG, also to minimize the degeneration of graft vessel.",
author = "Dongsoo Kim and Kwon, {Hyuck Moon} and Lee, {Byung Kwon} and Yangsoo Jang and Suh, {Sang Ho} and Yoo, {Sang Shin} and Kim, {Hyun Seung}",
year = "1998",
month = "1",
day = "1",
doi = "10.3346/jkms.1998.13.3.263",
language = "English",
volume = "13",
pages = "263--268",
journal = "Journal of Korean Medical Science",
issn = "1011-8934",
publisher = "Korean Academy of Medical Science",
number = "3",

}

Hemodynamic effects of the geometric dimensions of graft vessels in Coronary Artery Bypass Graft models. / Kim, Dongsoo; Kwon, Hyuck Moon; Lee, Byung Kwon; Jang, Yangsoo; Suh, Sang Ho; Yoo, Sang Shin; Kim, Hyun Seung.

In: Journal of Korean Medical Science, Vol. 13, No. 3, 01.01.1998, p. 263-268.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Hemodynamic effects of the geometric dimensions of graft vessels in Coronary Artery Bypass Graft models

AU - Kim, Dongsoo

AU - Kwon, Hyuck Moon

AU - Lee, Byung Kwon

AU - Jang, Yangsoo

AU - Suh, Sang Ho

AU - Yoo, Sang Shin

AU - Kim, Hyun Seung

PY - 1998/1/1

Y1 - 1998/1/1

N2 - The objectives of this investigation are to evaluate the rheologic properties in atherosclerotic disease treated with the various coronary artery bypass graft (CABG) models by numerical analysis, we used four different CABG models for the assessment of spatial fluctuation in wall shear stress, pressure variation and mass flow rate with Carreau model and Navier-Stokes equation. Wall shear stress was higher in a naturally tapered model (model 1) and a constant (non-tapered) diameter of the graft vessel the same as the distal LAD (model 4) than in others. Pressure variation along the native coronary artery and graft vessels was higher in a model 4, model 1 than in a reverse tapering model (model 2) and a constant diameter of the graft vessel the same as the proximal LAD (model 3). The mass flow rate of the distal part (kg/sec, mo) was the highest in model 3. This study suggests that in vitro spatial simulation following CABG revealed that small caliber or tapered graft vessels have adverse hemodynamic effects on the native and graft vessels. By this technique it is possible to simulate the optimal distribution of local hemodynamic variables in patients treated with CABG, also to minimize the degeneration of graft vessel.

AB - The objectives of this investigation are to evaluate the rheologic properties in atherosclerotic disease treated with the various coronary artery bypass graft (CABG) models by numerical analysis, we used four different CABG models for the assessment of spatial fluctuation in wall shear stress, pressure variation and mass flow rate with Carreau model and Navier-Stokes equation. Wall shear stress was higher in a naturally tapered model (model 1) and a constant (non-tapered) diameter of the graft vessel the same as the distal LAD (model 4) than in others. Pressure variation along the native coronary artery and graft vessels was higher in a model 4, model 1 than in a reverse tapering model (model 2) and a constant diameter of the graft vessel the same as the proximal LAD (model 3). The mass flow rate of the distal part (kg/sec, mo) was the highest in model 3. This study suggests that in vitro spatial simulation following CABG revealed that small caliber or tapered graft vessels have adverse hemodynamic effects on the native and graft vessels. By this technique it is possible to simulate the optimal distribution of local hemodynamic variables in patients treated with CABG, also to minimize the degeneration of graft vessel.

UR - http://www.scopus.com/inward/record.url?scp=0032084736&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032084736&partnerID=8YFLogxK

U2 - 10.3346/jkms.1998.13.3.263

DO - 10.3346/jkms.1998.13.3.263

M3 - Article

VL - 13

SP - 263

EP - 268

JO - Journal of Korean Medical Science

JF - Journal of Korean Medical Science

SN - 1011-8934

IS - 3

ER -