High-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions

Tie Qiang Li, Donghyun Kim, Michael E. Moseley

Research output: Contribution to journalArticle

22 Citations (Scopus)

Abstract

Purpose: To develop a multishot magnetic resonance imaging (MRI) pulse sequence and reconstruction algorithm for diffusion-eighted imaging (DWI) in the brain with sub-millimeter in-plane resolution. Materials and Methods: A self-navigated multishot acquisition technique based on variable-density spiral k-space trajectory design was implemented on clinical MRI scanners. The image reconstruction algorithm takes advantage of the oversampling of the center k-space and uses the densely sampled central portion of the k-space data for both imaging reconstruction and motion correction. The developed DWI technique was tested in an agar gel phantom and three healthy volunteers. Results: Motions result in phase and k-space shifts in the DWI data acquired using multishot spiral acquisitions. With the two-dimensional self-navigator correction, diffusion-weighted images with a resolution of 0.9 × 0.9 × 3 mm 3 were successfully obtained using different interleaves ranging from 8-32. The measured apparent diffusion coefficient (ADC) in the homogenous gel phantom was (1.66 ± 0.09) × 10-3 mm2/second, which was the same as measured with single-shot methods. The intersubject average ADC from the brain parenchyma of normal adults was (0.91 ± 0.01) × 10-3 mm2/second, which was in a good agreement with the reported literature values. Conclusion: The self-navigated multishot variable-density spiral acquisition provides a time-efficient approach to acquire high-resolution diffusion-weighted images on a clinical scanner. The reconstruction algorithm based on motion correction in the k-space data is robust, and measured ADC values are accurate and reproducible.

Original languageEnglish
Pages (from-to)468-475
Number of pages8
JournalJournal of Magnetic Resonance Imaging
Volume21
Issue number4
DOIs
Publication statusPublished - 2005 Apr 1

Fingerprint

Gels
Magnetic Resonance Imaging
Computer-Assisted Image Processing
Brain
Agar
Healthy Volunteers

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Cite this

@article{d7327860e8454afea91267106a33c835,
title = "High-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions",
abstract = "Purpose: To develop a multishot magnetic resonance imaging (MRI) pulse sequence and reconstruction algorithm for diffusion-eighted imaging (DWI) in the brain with sub-millimeter in-plane resolution. Materials and Methods: A self-navigated multishot acquisition technique based on variable-density spiral k-space trajectory design was implemented on clinical MRI scanners. The image reconstruction algorithm takes advantage of the oversampling of the center k-space and uses the densely sampled central portion of the k-space data for both imaging reconstruction and motion correction. The developed DWI technique was tested in an agar gel phantom and three healthy volunteers. Results: Motions result in phase and k-space shifts in the DWI data acquired using multishot spiral acquisitions. With the two-dimensional self-navigator correction, diffusion-weighted images with a resolution of 0.9 × 0.9 × 3 mm 3 were successfully obtained using different interleaves ranging from 8-32. The measured apparent diffusion coefficient (ADC) in the homogenous gel phantom was (1.66 ± 0.09) × 10-3 mm2/second, which was the same as measured with single-shot methods. The intersubject average ADC from the brain parenchyma of normal adults was (0.91 ± 0.01) × 10-3 mm2/second, which was in a good agreement with the reported literature values. Conclusion: The self-navigated multishot variable-density spiral acquisition provides a time-efficient approach to acquire high-resolution diffusion-weighted images on a clinical scanner. The reconstruction algorithm based on motion correction in the k-space data is robust, and measured ADC values are accurate and reproducible.",
author = "Li, {Tie Qiang} and Donghyun Kim and Moseley, {Michael E.}",
year = "2005",
month = "4",
day = "1",
doi = "10.1002/jmri.20287",
language = "English",
volume = "21",
pages = "468--475",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "4",

}

High-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions. / Li, Tie Qiang; Kim, Donghyun; Moseley, Michael E.

In: Journal of Magnetic Resonance Imaging, Vol. 21, No. 4, 01.04.2005, p. 468-475.

Research output: Contribution to journalArticle

TY - JOUR

T1 - High-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions

AU - Li, Tie Qiang

AU - Kim, Donghyun

AU - Moseley, Michael E.

PY - 2005/4/1

Y1 - 2005/4/1

N2 - Purpose: To develop a multishot magnetic resonance imaging (MRI) pulse sequence and reconstruction algorithm for diffusion-eighted imaging (DWI) in the brain with sub-millimeter in-plane resolution. Materials and Methods: A self-navigated multishot acquisition technique based on variable-density spiral k-space trajectory design was implemented on clinical MRI scanners. The image reconstruction algorithm takes advantage of the oversampling of the center k-space and uses the densely sampled central portion of the k-space data for both imaging reconstruction and motion correction. The developed DWI technique was tested in an agar gel phantom and three healthy volunteers. Results: Motions result in phase and k-space shifts in the DWI data acquired using multishot spiral acquisitions. With the two-dimensional self-navigator correction, diffusion-weighted images with a resolution of 0.9 × 0.9 × 3 mm 3 were successfully obtained using different interleaves ranging from 8-32. The measured apparent diffusion coefficient (ADC) in the homogenous gel phantom was (1.66 ± 0.09) × 10-3 mm2/second, which was the same as measured with single-shot methods. The intersubject average ADC from the brain parenchyma of normal adults was (0.91 ± 0.01) × 10-3 mm2/second, which was in a good agreement with the reported literature values. Conclusion: The self-navigated multishot variable-density spiral acquisition provides a time-efficient approach to acquire high-resolution diffusion-weighted images on a clinical scanner. The reconstruction algorithm based on motion correction in the k-space data is robust, and measured ADC values are accurate and reproducible.

AB - Purpose: To develop a multishot magnetic resonance imaging (MRI) pulse sequence and reconstruction algorithm for diffusion-eighted imaging (DWI) in the brain with sub-millimeter in-plane resolution. Materials and Methods: A self-navigated multishot acquisition technique based on variable-density spiral k-space trajectory design was implemented on clinical MRI scanners. The image reconstruction algorithm takes advantage of the oversampling of the center k-space and uses the densely sampled central portion of the k-space data for both imaging reconstruction and motion correction. The developed DWI technique was tested in an agar gel phantom and three healthy volunteers. Results: Motions result in phase and k-space shifts in the DWI data acquired using multishot spiral acquisitions. With the two-dimensional self-navigator correction, diffusion-weighted images with a resolution of 0.9 × 0.9 × 3 mm 3 were successfully obtained using different interleaves ranging from 8-32. The measured apparent diffusion coefficient (ADC) in the homogenous gel phantom was (1.66 ± 0.09) × 10-3 mm2/second, which was the same as measured with single-shot methods. The intersubject average ADC from the brain parenchyma of normal adults was (0.91 ± 0.01) × 10-3 mm2/second, which was in a good agreement with the reported literature values. Conclusion: The self-navigated multishot variable-density spiral acquisition provides a time-efficient approach to acquire high-resolution diffusion-weighted images on a clinical scanner. The reconstruction algorithm based on motion correction in the k-space data is robust, and measured ADC values are accurate and reproducible.

UR - http://www.scopus.com/inward/record.url?scp=15944375792&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=15944375792&partnerID=8YFLogxK

U2 - 10.1002/jmri.20287

DO - 10.1002/jmri.20287

M3 - Article

C2 - 15779030

AN - SCOPUS:15944375792

VL - 21

SP - 468

EP - 475

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 4

ER -