I-P relationship and effective capacitance in external electrode fluorescent lamp

Tae Il Lee, Hyeon Seok Hwang, Ki Wan Park, Hong Koo Baik

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The authors derived an analytical relationship between rms tube current and input power for various capacitances of the external electrode part and measured their effective capacitances in an external electrode fluorescent lamp. From the fitting derived relation in the measured data, the reliability of the authors' derivation was certain and effective capacitances were measured. Consequently, it is confirmed that the derived relationship is very useful in estimating the effective capacitance of the external electrode part for any shape of glass tube and electrodes during the lamp operation.

Original languageEnglish
Article number231501
JournalApplied Physics Letters
Volume89
Issue number23
DOIs
Publication statusPublished - 2006 Dec 18

Fingerprint

luminaires
capacitance
electrodes
tubes
estimating
derivation
glass

All Science Journal Classification (ASJC) codes

  • Physics and Astronomy (miscellaneous)

Cite this

Lee, Tae Il ; Hwang, Hyeon Seok ; Park, Ki Wan ; Baik, Hong Koo. / I-P relationship and effective capacitance in external electrode fluorescent lamp. In: Applied Physics Letters. 2006 ; Vol. 89, No. 23.
@article{a05901d3660942a38c9ff7866573ec8b,
title = "I-P relationship and effective capacitance in external electrode fluorescent lamp",
abstract = "The authors derived an analytical relationship between rms tube current and input power for various capacitances of the external electrode part and measured their effective capacitances in an external electrode fluorescent lamp. From the fitting derived relation in the measured data, the reliability of the authors' derivation was certain and effective capacitances were measured. Consequently, it is confirmed that the derived relationship is very useful in estimating the effective capacitance of the external electrode part for any shape of glass tube and electrodes during the lamp operation.",
author = "Lee, {Tae Il} and Hwang, {Hyeon Seok} and Park, {Ki Wan} and Baik, {Hong Koo}",
year = "2006",
month = "12",
day = "18",
doi = "10.1063/1.2400073",
language = "English",
volume = "89",
journal = "Applied Physics Letters",
issn = "0003-6951",
publisher = "American Institute of Physics Publising LLC",
number = "23",

}

I-P relationship and effective capacitance in external electrode fluorescent lamp. / Lee, Tae Il; Hwang, Hyeon Seok; Park, Ki Wan; Baik, Hong Koo.

In: Applied Physics Letters, Vol. 89, No. 23, 231501, 18.12.2006.

Research output: Contribution to journalArticle

TY - JOUR

T1 - I-P relationship and effective capacitance in external electrode fluorescent lamp

AU - Lee, Tae Il

AU - Hwang, Hyeon Seok

AU - Park, Ki Wan

AU - Baik, Hong Koo

PY - 2006/12/18

Y1 - 2006/12/18

N2 - The authors derived an analytical relationship between rms tube current and input power for various capacitances of the external electrode part and measured their effective capacitances in an external electrode fluorescent lamp. From the fitting derived relation in the measured data, the reliability of the authors' derivation was certain and effective capacitances were measured. Consequently, it is confirmed that the derived relationship is very useful in estimating the effective capacitance of the external electrode part for any shape of glass tube and electrodes during the lamp operation.

AB - The authors derived an analytical relationship between rms tube current and input power for various capacitances of the external electrode part and measured their effective capacitances in an external electrode fluorescent lamp. From the fitting derived relation in the measured data, the reliability of the authors' derivation was certain and effective capacitances were measured. Consequently, it is confirmed that the derived relationship is very useful in estimating the effective capacitance of the external electrode part for any shape of glass tube and electrodes during the lamp operation.

UR - http://www.scopus.com/inward/record.url?scp=33845392801&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33845392801&partnerID=8YFLogxK

U2 - 10.1063/1.2400073

DO - 10.1063/1.2400073

M3 - Article

AN - SCOPUS:33845392801

VL - 89

JO - Applied Physics Letters

JF - Applied Physics Letters

SN - 0003-6951

IS - 23

M1 - 231501

ER -