Influence of preparation design on fit and ceramic thickness of CEREC 3 partial ceramic crowns after cementation

Jae Hoon Kim, Byeong Hoon Cho, Jin Hee Lee, Soo Jung Kwon, Young Ah Yi, Yooseok Shin, Byoung Duck Roh, Deog Gyu Seo

Research output: Contribution to journalArticlepeer-review

23 Citations (Scopus)

Abstract

Objective. This study investigated the influence of preparation design on the marginal and internal gap and ceramic thickness of partial ceramic crowns (PCCs) fabricated with the CEREC 3 system. Materials and methods. Sixteen extracted human mandibular molars were prepared according to two different preparation designs (n = 8): a retentive preparation design with traditional cusp capping (Group I) and a non-retentive preparation design with horizontal reduction of cusps (Group II). PCCs were fabricated from IPS Empress CAD with the CEREC 3 system. The parameters for luting space and minimum occlusal ceramic thickness were set to 30 mm and 1.5 mm, respectively. The fabricated PCCs were cemented to their corresponding teeth with self-adhesive resin cement and were then scanned by micro-computed tomography. The marginal and internal gaps were measured at pre-determined measuring points in five bucco-lingual and three mesio-distal cross-sectional images. The ceramic thicknesses of the PCCs were measured at the measuring points for cusp capping areas. Results. Group II (167.4 ± 76.4 μm) had a smaller overall mean gap, which included the marginal and internal gap measurements, than that of Group I (184.8 ± 89.0 μm). The internal gaps were larger than the marginal gaps, regardless of preparation design. Group I presented a thinner ceramic thickness in the cusp capping areas than the minimum occlusal ceramic thickness parameter of 1.5 mm. Conclusion. Preparation design had an influence on fit, particularly the internal gap of the PCCs. Ceramic thickness could be thinner than the minimum ceramic thickness parameter.

Original languageEnglish
Pages (from-to)107-113
Number of pages7
JournalActa odontologica Scandinavica
Volume73
Issue number2
DOIs
Publication statusPublished - 2014 Apr 1

Bibliographical note

Funding Information:
This study was supported by the Basic Science Research Program through the National Research Foundation (NRF) of Korea, funded by the Ministry of Education, Science, and Technology (2010-0005090, 2012-009268). The authors thank Dentsply for the kind donation of materials for this investigation.

Publisher Copyright:
© 2014 Informa Healthcare.

All Science Journal Classification (ASJC) codes

  • Dentistry(all)

Fingerprint

Dive into the research topics of 'Influence of preparation design on fit and ceramic thickness of CEREC 3 partial ceramic crowns after cementation'. Together they form a unique fingerprint.

Cite this