Load-carrying behavior of tranmission-tower connected foundations subjected to different load directions

Doohyun Kyung, Jun Hwan Lee

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Connected foundations comprise an effective option for improving the mechanical performance of transmission tower foundations. In this study, the load-carrying behavior of connected foundations for transmission tower structures was investigated focusing on the effect of the load direction based on the field experimental testing program. Improved performances of connected foundations were observed for load directions of both θ=0° and 45° considered in this study. The downward settlements at the compressive side for θ=45° were larger than those for θ=0°, while the upward displacements were similar. For both vertical and lateral displacements, the use of connected foundations was more effective for θ=45°, and the effectiveness became more pronounced as the connection-beam stiffness increased. However, the lateral load-carrying capacities for θ=0° and 45° were not significantly different for all connection-beam conditions. From the prototype-scaled model load tests, it was confirmed that the use of connected foundations for transmission tower structures is similarly effective for different load directions. Based on the test results, it was suggested that a unified design methodology is applicable for the stability analysis of transmission tower structures subjected to different load directions.

Original languageEnglish
Pages (from-to)575-587
Number of pages13
JournalSoils and Foundations
Volume55
Issue number3
DOIs
Publication statusPublished - 2015 Jun 1

Fingerprint

Towers
carrying capacity
stability analysis
stiffness
methodology
Load limits
test
Stiffness
Testing
effect
programme

All Science Journal Classification (ASJC) codes

  • Civil and Structural Engineering
  • Geotechnical Engineering and Engineering Geology

Cite this

@article{d15894ab6c5e47ffaa4dd3649fba2d0b,
title = "Load-carrying behavior of tranmission-tower connected foundations subjected to different load directions",
abstract = "Connected foundations comprise an effective option for improving the mechanical performance of transmission tower foundations. In this study, the load-carrying behavior of connected foundations for transmission tower structures was investigated focusing on the effect of the load direction based on the field experimental testing program. Improved performances of connected foundations were observed for load directions of both θ=0° and 45° considered in this study. The downward settlements at the compressive side for θ=45° were larger than those for θ=0°, while the upward displacements were similar. For both vertical and lateral displacements, the use of connected foundations was more effective for θ=45°, and the effectiveness became more pronounced as the connection-beam stiffness increased. However, the lateral load-carrying capacities for θ=0° and 45° were not significantly different for all connection-beam conditions. From the prototype-scaled model load tests, it was confirmed that the use of connected foundations for transmission tower structures is similarly effective for different load directions. Based on the test results, it was suggested that a unified design methodology is applicable for the stability analysis of transmission tower structures subjected to different load directions.",
author = "Doohyun Kyung and Lee, {Jun Hwan}",
year = "2015",
month = "6",
day = "1",
doi = "10.1016/j.sandf.2015.04.009",
language = "English",
volume = "55",
pages = "575--587",
journal = "Soils and Foundations",
issn = "0038-0806",
publisher = "Japanese Geotechnical Society",
number = "3",

}

Load-carrying behavior of tranmission-tower connected foundations subjected to different load directions. / Kyung, Doohyun; Lee, Jun Hwan.

In: Soils and Foundations, Vol. 55, No. 3, 01.06.2015, p. 575-587.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Load-carrying behavior of tranmission-tower connected foundations subjected to different load directions

AU - Kyung, Doohyun

AU - Lee, Jun Hwan

PY - 2015/6/1

Y1 - 2015/6/1

N2 - Connected foundations comprise an effective option for improving the mechanical performance of transmission tower foundations. In this study, the load-carrying behavior of connected foundations for transmission tower structures was investigated focusing on the effect of the load direction based on the field experimental testing program. Improved performances of connected foundations were observed for load directions of both θ=0° and 45° considered in this study. The downward settlements at the compressive side for θ=45° were larger than those for θ=0°, while the upward displacements were similar. For both vertical and lateral displacements, the use of connected foundations was more effective for θ=45°, and the effectiveness became more pronounced as the connection-beam stiffness increased. However, the lateral load-carrying capacities for θ=0° and 45° were not significantly different for all connection-beam conditions. From the prototype-scaled model load tests, it was confirmed that the use of connected foundations for transmission tower structures is similarly effective for different load directions. Based on the test results, it was suggested that a unified design methodology is applicable for the stability analysis of transmission tower structures subjected to different load directions.

AB - Connected foundations comprise an effective option for improving the mechanical performance of transmission tower foundations. In this study, the load-carrying behavior of connected foundations for transmission tower structures was investigated focusing on the effect of the load direction based on the field experimental testing program. Improved performances of connected foundations were observed for load directions of both θ=0° and 45° considered in this study. The downward settlements at the compressive side for θ=45° were larger than those for θ=0°, while the upward displacements were similar. For both vertical and lateral displacements, the use of connected foundations was more effective for θ=45°, and the effectiveness became more pronounced as the connection-beam stiffness increased. However, the lateral load-carrying capacities for θ=0° and 45° were not significantly different for all connection-beam conditions. From the prototype-scaled model load tests, it was confirmed that the use of connected foundations for transmission tower structures is similarly effective for different load directions. Based on the test results, it was suggested that a unified design methodology is applicable for the stability analysis of transmission tower structures subjected to different load directions.

UR - http://www.scopus.com/inward/record.url?scp=84937811541&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84937811541&partnerID=8YFLogxK

U2 - 10.1016/j.sandf.2015.04.009

DO - 10.1016/j.sandf.2015.04.009

M3 - Article

AN - SCOPUS:84937811541

VL - 55

SP - 575

EP - 587

JO - Soils and Foundations

JF - Soils and Foundations

SN - 0038-0806

IS - 3

ER -