TY - JOUR
T1 - Local delivery of nitric oxide from an eluting stent to inhibit neointimal thickening in a porcine coronary injury model
AU - Yoon, Junghan
AU - Wu, Chiung Jen
AU - Homme, James
AU - Tuch, Ronald J.
AU - Wolff, Rodney G.
AU - Topol, Eric J.
AU - Michael Lincoff, A.
PY - 2002
Y1 - 2002
N2 - To assess the effect of a NO-eluting stent on reducing neointimal thickening in a porcine coronary artery stent injury model, sodium nitroprusside (SNP), a NO donor, was incorporated into polyurethane (PU) polymer and coated onto metallic coil stents, and two types of stents with thin and thick barrier coatings were characterized. In vivo biological activity of the NO-eluting stents was assessed by measurement of coronary arterial cGMP levels in 32 pigs/64 arteries at days 1, 2, 7 and 14. Morphometric analyses were performed in 16 pigs to determine the effect of NO-eluting stents on neointimal hyperplasia 28 days following arterial injury. The SNP-coated stents released NO in a controlled manner for up to 4 weeks in the in vitro experiments and an increase in local tissue cGMP levels was demonstrated for up to 14 days. The neointimal area at 28 days was not diminished, however, by NO eluded from either stents of thin or thick barriers (control bare stent - 0.66 mm2, control PU stent - 0.68 mm2, SNP-PU thin coating stent -0.78 mm2, SNP-PU thick coating stent - 0.85 mm2; all p=NS). In conclusion, the SNP-coated polymer stent exerted a local biological effect on the arterial wall, with sustained elevation of cGMP level. Although local delivery of NO from this device did not reduce neointimal hyperplasia in this porcine model, this polymer-coated stent might be a promising tool for administration of other agents that may modify the reparative tissue responses leading to restenosis.
AB - To assess the effect of a NO-eluting stent on reducing neointimal thickening in a porcine coronary artery stent injury model, sodium nitroprusside (SNP), a NO donor, was incorporated into polyurethane (PU) polymer and coated onto metallic coil stents, and two types of stents with thin and thick barrier coatings were characterized. In vivo biological activity of the NO-eluting stents was assessed by measurement of coronary arterial cGMP levels in 32 pigs/64 arteries at days 1, 2, 7 and 14. Morphometric analyses were performed in 16 pigs to determine the effect of NO-eluting stents on neointimal hyperplasia 28 days following arterial injury. The SNP-coated stents released NO in a controlled manner for up to 4 weeks in the in vitro experiments and an increase in local tissue cGMP levels was demonstrated for up to 14 days. The neointimal area at 28 days was not diminished, however, by NO eluded from either stents of thin or thick barriers (control bare stent - 0.66 mm2, control PU stent - 0.68 mm2, SNP-PU thin coating stent -0.78 mm2, SNP-PU thick coating stent - 0.85 mm2; all p=NS). In conclusion, the SNP-coated polymer stent exerted a local biological effect on the arterial wall, with sustained elevation of cGMP level. Although local delivery of NO from this device did not reduce neointimal hyperplasia in this porcine model, this polymer-coated stent might be a promising tool for administration of other agents that may modify the reparative tissue responses leading to restenosis.
UR - http://www.scopus.com/inward/record.url?scp=0036247749&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036247749&partnerID=8YFLogxK
U2 - 10.3349/ymj.2002.43.2.242
DO - 10.3349/ymj.2002.43.2.242
M3 - Article
C2 - 11971219
AN - SCOPUS:0036247749
SN - 0513-5796
VL - 43
SP - 242
EP - 251
JO - Yonsei Medical Journal
JF - Yonsei Medical Journal
IS - 2