Abstract

Multiple low index particles (micrometer-sized ultrasound contrast agent), have been optically trapped using a 4 × 4 Laguerre-Gaussian trap array. The trapping efficiency of the Laguerre-Gaussian arrangement was measured using a Stokes' flow approach whereby the critical relative fluid velocity required to remove particles from the optical trap was measured. The dependence of trapping efficiency on beam power was also explored and the optimum beam parameters were identified. Finally, the utility of the array as a selective filter was demonstrated by tweezing multiple low-index particles from a population exhibiting an inherent distribution in size. This procedure represents a unique remote non-contact process that may have significant applicability throughout the fields of biophysics and biotechnology.

Original languageEnglish
Pages (from-to)593-600
Number of pages8
JournalOptics Express
Volume12
Issue number4
DOIs
Publication statusPublished - 2004 Feb

Fingerprint

manipulators
traps
trapping
biophysics
Stokes flow
biotechnology
micrometers
filters
fluids

All Science Journal Classification (ASJC) codes

  • Atomic and Molecular Physics, and Optics

Cite this

Prentice, P. A., MacDonald, M. P., Frank, T. G., Cuschieri, A., Spalding, G. C., Sibbett, W., ... Dholakia, K. (2004). Manipulation and filtration of low index particles with holographic Laguerre-Gaussian optical trap arrays. Optics Express, 12(4), 593-600. https://doi.org/10.1364/OPEX.12.000593
Prentice, P. A. ; MacDonald, M. P. ; Frank, T. G. ; Cuschieri, A. ; Spalding, G. C. ; Sibbett, W. ; Campbell, P. A. ; Dholakia, K. / Manipulation and filtration of low index particles with holographic Laguerre-Gaussian optical trap arrays. In: Optics Express. 2004 ; Vol. 12, No. 4. pp. 593-600.
@article{be5348399c38490a892de6ef768d2d03,
title = "Manipulation and filtration of low index particles with holographic Laguerre-Gaussian optical trap arrays",
abstract = "Multiple low index particles (micrometer-sized ultrasound contrast agent), have been optically trapped using a 4 × 4 Laguerre-Gaussian trap array. The trapping efficiency of the Laguerre-Gaussian arrangement was measured using a Stokes' flow approach whereby the critical relative fluid velocity required to remove particles from the optical trap was measured. The dependence of trapping efficiency on beam power was also explored and the optimum beam parameters were identified. Finally, the utility of the array as a selective filter was demonstrated by tweezing multiple low-index particles from a population exhibiting an inherent distribution in size. This procedure represents a unique remote non-contact process that may have significant applicability throughout the fields of biophysics and biotechnology.",
author = "Prentice, {P. A.} and MacDonald, {M. P.} and Frank, {T. G.} and A. Cuschieri and Spalding, {G. C.} and W. Sibbett and Campbell, {P. A.} and K. Dholakia",
year = "2004",
month = "2",
doi = "10.1364/OPEX.12.000593",
language = "English",
volume = "12",
pages = "593--600",
journal = "Optics Express",
issn = "1094-4087",
publisher = "The Optical Society",
number = "4",

}

Prentice, PA, MacDonald, MP, Frank, TG, Cuschieri, A, Spalding, GC, Sibbett, W, Campbell, PA & Dholakia, K 2004, 'Manipulation and filtration of low index particles with holographic Laguerre-Gaussian optical trap arrays', Optics Express, vol. 12, no. 4, pp. 593-600. https://doi.org/10.1364/OPEX.12.000593

Manipulation and filtration of low index particles with holographic Laguerre-Gaussian optical trap arrays. / Prentice, P. A.; MacDonald, M. P.; Frank, T. G.; Cuschieri, A.; Spalding, G. C.; Sibbett, W.; Campbell, P. A.; Dholakia, K.

In: Optics Express, Vol. 12, No. 4, 02.2004, p. 593-600.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Manipulation and filtration of low index particles with holographic Laguerre-Gaussian optical trap arrays

AU - Prentice, P. A.

AU - MacDonald, M. P.

AU - Frank, T. G.

AU - Cuschieri, A.

AU - Spalding, G. C.

AU - Sibbett, W.

AU - Campbell, P. A.

AU - Dholakia, K.

PY - 2004/2

Y1 - 2004/2

N2 - Multiple low index particles (micrometer-sized ultrasound contrast agent), have been optically trapped using a 4 × 4 Laguerre-Gaussian trap array. The trapping efficiency of the Laguerre-Gaussian arrangement was measured using a Stokes' flow approach whereby the critical relative fluid velocity required to remove particles from the optical trap was measured. The dependence of trapping efficiency on beam power was also explored and the optimum beam parameters were identified. Finally, the utility of the array as a selective filter was demonstrated by tweezing multiple low-index particles from a population exhibiting an inherent distribution in size. This procedure represents a unique remote non-contact process that may have significant applicability throughout the fields of biophysics and biotechnology.

AB - Multiple low index particles (micrometer-sized ultrasound contrast agent), have been optically trapped using a 4 × 4 Laguerre-Gaussian trap array. The trapping efficiency of the Laguerre-Gaussian arrangement was measured using a Stokes' flow approach whereby the critical relative fluid velocity required to remove particles from the optical trap was measured. The dependence of trapping efficiency on beam power was also explored and the optimum beam parameters were identified. Finally, the utility of the array as a selective filter was demonstrated by tweezing multiple low-index particles from a population exhibiting an inherent distribution in size. This procedure represents a unique remote non-contact process that may have significant applicability throughout the fields of biophysics and biotechnology.

UR - http://www.scopus.com/inward/record.url?scp=2942702200&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=2942702200&partnerID=8YFLogxK

U2 - 10.1364/OPEX.12.000593

DO - 10.1364/OPEX.12.000593

M3 - Article

C2 - 19474861

AN - SCOPUS:2942702200

VL - 12

SP - 593

EP - 600

JO - Optics Express

JF - Optics Express

SN - 1094-4087

IS - 4

ER -

Prentice PA, MacDonald MP, Frank TG, Cuschieri A, Spalding GC, Sibbett W et al. Manipulation and filtration of low index particles with holographic Laguerre-Gaussian optical trap arrays. Optics Express. 2004 Feb;12(4):593-600. https://doi.org/10.1364/OPEX.12.000593