Measurement of cooked noodle stickiness using a modified instrumental method

Seung Ju Lee, Mikyoung Rha, Wonbang Koh, Woojoon Park, Chiho Lee, Young An Kwon, Jae-Kwan Hwang

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

Stickiness of cooked noodles, generally defined as a maximum force in tension after compression, depends on the compression force, contact area, and physical properties of the noodles. In the conventional method of measuring stickiness, only compression force was set as a standard, neglecting the other probable influencing factors. A modified method was developed for measuring contact area between noodles and a probe, in addition to the compression force. Four specimens with varying starch contents (0, 30, 60, and 90%) were tested to evaluate the new method for measuring cooked noodle stickiness. Contact area calculated from the displacement of probe at the compression condition was not consistent among the noodle samples. A corrected stickiness and a corrected compression force were defined as a simple stickiness directly measured for the contact area and the compression force measured for the contact area, respectively. This method proved to be a more effective means in differentiating the stickiness among noodle samples (than using just compression force factors). The order in the corrected stickiness magnitudes among the noodles was consistent regardless of specimen amount used in the measurements, whereas that of the simple stickiness was inconsistent when different size samples were used. The corrected compression force estimated from a fixed simple compression force, which is a true compression stress, varied among the noodles. Accordingly, the corrected compression force was a more accurate criteria for stickiness measurements than was the simple compression force, which subjects the specimens to only differences in compression for stickiness comparison. The corrected stickiness results showed greater relationship to sensory stickiness and starch content than the simple stickiness measurement.

Original languageEnglish
Pages (from-to)838-842
Number of pages5
JournalCereal Chemistry
Volume79
Issue number6
DOIs
Publication statusPublished - 2002 Jan 1

Fingerprint

stickiness
noodles
Starch
Physical properties
methodology
Sample Size
starch
sampling
physical properties

All Science Journal Classification (ASJC) codes

  • Food Science
  • Organic Chemistry

Cite this

Lee, Seung Ju ; Rha, Mikyoung ; Koh, Wonbang ; Park, Woojoon ; Lee, Chiho ; Kwon, Young An ; Hwang, Jae-Kwan. / Measurement of cooked noodle stickiness using a modified instrumental method. In: Cereal Chemistry. 2002 ; Vol. 79, No. 6. pp. 838-842.
@article{f766d4cafa3042f3b94ac2767b8314e6,
title = "Measurement of cooked noodle stickiness using a modified instrumental method",
abstract = "Stickiness of cooked noodles, generally defined as a maximum force in tension after compression, depends on the compression force, contact area, and physical properties of the noodles. In the conventional method of measuring stickiness, only compression force was set as a standard, neglecting the other probable influencing factors. A modified method was developed for measuring contact area between noodles and a probe, in addition to the compression force. Four specimens with varying starch contents (0, 30, 60, and 90{\%}) were tested to evaluate the new method for measuring cooked noodle stickiness. Contact area calculated from the displacement of probe at the compression condition was not consistent among the noodle samples. A corrected stickiness and a corrected compression force were defined as a simple stickiness directly measured for the contact area and the compression force measured for the contact area, respectively. This method proved to be a more effective means in differentiating the stickiness among noodle samples (than using just compression force factors). The order in the corrected stickiness magnitudes among the noodles was consistent regardless of specimen amount used in the measurements, whereas that of the simple stickiness was inconsistent when different size samples were used. The corrected compression force estimated from a fixed simple compression force, which is a true compression stress, varied among the noodles. Accordingly, the corrected compression force was a more accurate criteria for stickiness measurements than was the simple compression force, which subjects the specimens to only differences in compression for stickiness comparison. The corrected stickiness results showed greater relationship to sensory stickiness and starch content than the simple stickiness measurement.",
author = "Lee, {Seung Ju} and Mikyoung Rha and Wonbang Koh and Woojoon Park and Chiho Lee and Kwon, {Young An} and Jae-Kwan Hwang",
year = "2002",
month = "1",
day = "1",
doi = "10.1094/CCHEM.2002.79.6.838",
language = "English",
volume = "79",
pages = "838--842",
journal = "Cereal Chemistry",
issn = "0009-0352",
publisher = "American Association of Cereal Chemists",
number = "6",

}

Measurement of cooked noodle stickiness using a modified instrumental method. / Lee, Seung Ju; Rha, Mikyoung; Koh, Wonbang; Park, Woojoon; Lee, Chiho; Kwon, Young An; Hwang, Jae-Kwan.

In: Cereal Chemistry, Vol. 79, No. 6, 01.01.2002, p. 838-842.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Measurement of cooked noodle stickiness using a modified instrumental method

AU - Lee, Seung Ju

AU - Rha, Mikyoung

AU - Koh, Wonbang

AU - Park, Woojoon

AU - Lee, Chiho

AU - Kwon, Young An

AU - Hwang, Jae-Kwan

PY - 2002/1/1

Y1 - 2002/1/1

N2 - Stickiness of cooked noodles, generally defined as a maximum force in tension after compression, depends on the compression force, contact area, and physical properties of the noodles. In the conventional method of measuring stickiness, only compression force was set as a standard, neglecting the other probable influencing factors. A modified method was developed for measuring contact area between noodles and a probe, in addition to the compression force. Four specimens with varying starch contents (0, 30, 60, and 90%) were tested to evaluate the new method for measuring cooked noodle stickiness. Contact area calculated from the displacement of probe at the compression condition was not consistent among the noodle samples. A corrected stickiness and a corrected compression force were defined as a simple stickiness directly measured for the contact area and the compression force measured for the contact area, respectively. This method proved to be a more effective means in differentiating the stickiness among noodle samples (than using just compression force factors). The order in the corrected stickiness magnitudes among the noodles was consistent regardless of specimen amount used in the measurements, whereas that of the simple stickiness was inconsistent when different size samples were used. The corrected compression force estimated from a fixed simple compression force, which is a true compression stress, varied among the noodles. Accordingly, the corrected compression force was a more accurate criteria for stickiness measurements than was the simple compression force, which subjects the specimens to only differences in compression for stickiness comparison. The corrected stickiness results showed greater relationship to sensory stickiness and starch content than the simple stickiness measurement.

AB - Stickiness of cooked noodles, generally defined as a maximum force in tension after compression, depends on the compression force, contact area, and physical properties of the noodles. In the conventional method of measuring stickiness, only compression force was set as a standard, neglecting the other probable influencing factors. A modified method was developed for measuring contact area between noodles and a probe, in addition to the compression force. Four specimens with varying starch contents (0, 30, 60, and 90%) were tested to evaluate the new method for measuring cooked noodle stickiness. Contact area calculated from the displacement of probe at the compression condition was not consistent among the noodle samples. A corrected stickiness and a corrected compression force were defined as a simple stickiness directly measured for the contact area and the compression force measured for the contact area, respectively. This method proved to be a more effective means in differentiating the stickiness among noodle samples (than using just compression force factors). The order in the corrected stickiness magnitudes among the noodles was consistent regardless of specimen amount used in the measurements, whereas that of the simple stickiness was inconsistent when different size samples were used. The corrected compression force estimated from a fixed simple compression force, which is a true compression stress, varied among the noodles. Accordingly, the corrected compression force was a more accurate criteria for stickiness measurements than was the simple compression force, which subjects the specimens to only differences in compression for stickiness comparison. The corrected stickiness results showed greater relationship to sensory stickiness and starch content than the simple stickiness measurement.

UR - http://www.scopus.com/inward/record.url?scp=0036841023&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036841023&partnerID=8YFLogxK

U2 - 10.1094/CCHEM.2002.79.6.838

DO - 10.1094/CCHEM.2002.79.6.838

M3 - Article

VL - 79

SP - 838

EP - 842

JO - Cereal Chemistry

JF - Cereal Chemistry

SN - 0009-0352

IS - 6

ER -