Abstract

Objective: To evaluate the effect of cortical bone thickness on the maximum insertion and removal torque of different types of self-drilling mini-screws and to determine if torque depends on the screw design. Materials and Methods: Three different types of self-drilling mini-screws (cylindrical type [Cl], taper type [Ta], taper type [Tb]) were inserted with the use of a driving torque tester at a constant speed of 3 rotations per minute. Experimental bone blocks with different cortical bone thicknesses were used as specimens. Results: Differences in the cortical bone thickness had little effect on the maximum insertion and removal torque in Cl. However, with Ta and Tb, the maximum insertion torque increased as the cortical bone thickness increased. The maximum insertion torque of Tb was highest in all situations, followed by Ta and Tb, in that order. Cl showed less torque loss in all cortical bone thicknesses and a longer removal time compared to Ta or Tb. There were significant relationships between cortical bone thickness, maximum insertion and removal torque, and implantation time in each type of self-drilling mini-screw. Conclusion: Since different screw designs showed different insertion torques with increases in cortical bone thickness, the suitable screw design should be selected according to the cortical thickness at the implant site.

Original languageEnglish
Pages (from-to)979-985
Number of pages7
JournalAngle Orthodontist
Volume77
Issue number6
DOIs
Publication statusPublished - 2007 Nov 1

Fingerprint

Torque
Orthodontics
Cortical Bone
Bone and Bones

All Science Journal Classification (ASJC) codes

  • Dentistry(all)

Cite this

@article{d947381162a94316a34f58d46763e6d8,
title = "Mechanical characteristics of various orthodontic mini-screws in relation to artificial cortical bone thickness",
abstract = "Objective: To evaluate the effect of cortical bone thickness on the maximum insertion and removal torque of different types of self-drilling mini-screws and to determine if torque depends on the screw design. Materials and Methods: Three different types of self-drilling mini-screws (cylindrical type [Cl], taper type [Ta], taper type [Tb]) were inserted with the use of a driving torque tester at a constant speed of 3 rotations per minute. Experimental bone blocks with different cortical bone thicknesses were used as specimens. Results: Differences in the cortical bone thickness had little effect on the maximum insertion and removal torque in Cl. However, with Ta and Tb, the maximum insertion torque increased as the cortical bone thickness increased. The maximum insertion torque of Tb was highest in all situations, followed by Ta and Tb, in that order. Cl showed less torque loss in all cortical bone thicknesses and a longer removal time compared to Ta or Tb. There were significant relationships between cortical bone thickness, maximum insertion and removal torque, and implantation time in each type of self-drilling mini-screw. Conclusion: Since different screw designs showed different insertion torques with increases in cortical bone thickness, the suitable screw design should be selected according to the cortical thickness at the implant site.",
author = "Song, {Young Youn} and Cha, {Jung Yul} and ChungJu Hwang",
year = "2007",
month = "11",
day = "1",
doi = "10.2319/090606-363.1",
language = "English",
volume = "77",
pages = "979--985",
journal = "Angle Orthodontist",
issn = "0003-3219",
publisher = "E H Angle Orthodontists Research & Education Foundation, Inc.",
number = "6",

}

Mechanical characteristics of various orthodontic mini-screws in relation to artificial cortical bone thickness. / Song, Young Youn; Cha, Jung Yul; Hwang, ChungJu.

In: Angle Orthodontist, Vol. 77, No. 6, 01.11.2007, p. 979-985.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Mechanical characteristics of various orthodontic mini-screws in relation to artificial cortical bone thickness

AU - Song, Young Youn

AU - Cha, Jung Yul

AU - Hwang, ChungJu

PY - 2007/11/1

Y1 - 2007/11/1

N2 - Objective: To evaluate the effect of cortical bone thickness on the maximum insertion and removal torque of different types of self-drilling mini-screws and to determine if torque depends on the screw design. Materials and Methods: Three different types of self-drilling mini-screws (cylindrical type [Cl], taper type [Ta], taper type [Tb]) were inserted with the use of a driving torque tester at a constant speed of 3 rotations per minute. Experimental bone blocks with different cortical bone thicknesses were used as specimens. Results: Differences in the cortical bone thickness had little effect on the maximum insertion and removal torque in Cl. However, with Ta and Tb, the maximum insertion torque increased as the cortical bone thickness increased. The maximum insertion torque of Tb was highest in all situations, followed by Ta and Tb, in that order. Cl showed less torque loss in all cortical bone thicknesses and a longer removal time compared to Ta or Tb. There were significant relationships between cortical bone thickness, maximum insertion and removal torque, and implantation time in each type of self-drilling mini-screw. Conclusion: Since different screw designs showed different insertion torques with increases in cortical bone thickness, the suitable screw design should be selected according to the cortical thickness at the implant site.

AB - Objective: To evaluate the effect of cortical bone thickness on the maximum insertion and removal torque of different types of self-drilling mini-screws and to determine if torque depends on the screw design. Materials and Methods: Three different types of self-drilling mini-screws (cylindrical type [Cl], taper type [Ta], taper type [Tb]) were inserted with the use of a driving torque tester at a constant speed of 3 rotations per minute. Experimental bone blocks with different cortical bone thicknesses were used as specimens. Results: Differences in the cortical bone thickness had little effect on the maximum insertion and removal torque in Cl. However, with Ta and Tb, the maximum insertion torque increased as the cortical bone thickness increased. The maximum insertion torque of Tb was highest in all situations, followed by Ta and Tb, in that order. Cl showed less torque loss in all cortical bone thicknesses and a longer removal time compared to Ta or Tb. There were significant relationships between cortical bone thickness, maximum insertion and removal torque, and implantation time in each type of self-drilling mini-screw. Conclusion: Since different screw designs showed different insertion torques with increases in cortical bone thickness, the suitable screw design should be selected according to the cortical thickness at the implant site.

UR - http://www.scopus.com/inward/record.url?scp=37649004793&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=37649004793&partnerID=8YFLogxK

U2 - 10.2319/090606-363.1

DO - 10.2319/090606-363.1

M3 - Article

VL - 77

SP - 979

EP - 985

JO - Angle Orthodontist

JF - Angle Orthodontist

SN - 0003-3219

IS - 6

ER -