Abstract

Most orthodontic appliances and archwires are stainless steel or nickel-titanium (NiTi) alloys that can release metal ions, with saliva as the medium. To measure metal released from the fixed orthodontic appliances currently in use, we fabricated simulated fixed orthodontic appliances that corresponded to half of the maxillary arch and soaked them in 50 mL of artificial saliva (pH 6.75 ± 0.15, 37°C) for 3 months. We used brackets, tubes, and bands made by Tomy (Tokyo, Japan). Four groups were established according to the appliance manufacturer and the type of metal in the .016 × .022-in archwires. Groups A and B were stainless steel archwires from Ormco (Glendora, Calif) and Dentaurum (Ispringen, Germany), respectively, and groups C and D were both NiTi archwires with Ormco’s copper NiTi and Tomy’s Bioforce sentalloy, respectively. Stainless steel archwires were heat treated in an electric furnace at 500°C for 1 minute and quenched in water. We measured the amount of metal released from each group by immersion time. Our conclusions were as follows: (1) there was no increase in the amount of chromium released after 4 weeks in group A, 2 weeks in group B, 3 weeks in group C, and 8 weeks in group D; (2) there was no increase in the amount of nickel released after 2 weeks in group A, 3 days in group B, 7 days in group C, and 3 weeks in group D; and (3) there was no increase in the amount of iron released after 2 weeks in group A, 3 days in group B, and 1 day in groups C and D. In our 3-month-long investigation, we saw a decrease in metal released as immersion time increased.

Original languageEnglish
Pages (from-to)383-391
Number of pages9
JournalAmerican Journal of Orthodontics and Dentofacial Orthopedics
Volume120
Issue number4
DOIs
Publication statusPublished - 2001 Jan 1

Fingerprint

Orthodontic Appliances
Metals
Stainless Steel
Immersion
Artificial Saliva
Tokyo
Chromium
Nickel
Saliva
Germany
Copper
Japan
Iron
Hot Temperature
Ions
Water
nitinol

All Science Journal Classification (ASJC) codes

  • Orthodontics

Cite this

@article{5c64cc7014d0461eac2be7c34f10eba9,
title = "Metal release from simulated fixed orthodontic appliances",
abstract = "Most orthodontic appliances and archwires are stainless steel or nickel-titanium (NiTi) alloys that can release metal ions, with saliva as the medium. To measure metal released from the fixed orthodontic appliances currently in use, we fabricated simulated fixed orthodontic appliances that corresponded to half of the maxillary arch and soaked them in 50 mL of artificial saliva (pH 6.75 ± 0.15, 37°C) for 3 months. We used brackets, tubes, and bands made by Tomy (Tokyo, Japan). Four groups were established according to the appliance manufacturer and the type of metal in the .016 × .022-in archwires. Groups A and B were stainless steel archwires from Ormco (Glendora, Calif) and Dentaurum (Ispringen, Germany), respectively, and groups C and D were both NiTi archwires with Ormco’s copper NiTi and Tomy’s Bioforce sentalloy, respectively. Stainless steel archwires were heat treated in an electric furnace at 500°C for 1 minute and quenched in water. We measured the amount of metal released from each group by immersion time. Our conclusions were as follows: (1) there was no increase in the amount of chromium released after 4 weeks in group A, 2 weeks in group B, 3 weeks in group C, and 8 weeks in group D; (2) there was no increase in the amount of nickel released after 2 weeks in group A, 3 days in group B, 7 days in group C, and 3 weeks in group D; and (3) there was no increase in the amount of iron released after 2 weeks in group A, 3 days in group B, and 1 day in groups C and D. In our 3-month-long investigation, we saw a decrease in metal released as immersion time increased.",
author = "ChungJu Hwang and Shin, {Ji Soo} and Cha, {Jung Yul}",
year = "2001",
month = "1",
day = "1",
doi = "10.1067/mod.2001.117911",
language = "English",
volume = "120",
pages = "383--391",
journal = "American Journal of Orthodontics and Dentofacial Orthopedics",
issn = "0889-5406",
publisher = "Mosby Inc.",
number = "4",

}

Metal release from simulated fixed orthodontic appliances. / Hwang, ChungJu; Shin, Ji Soo; Cha, Jung Yul.

In: American Journal of Orthodontics and Dentofacial Orthopedics, Vol. 120, No. 4, 01.01.2001, p. 383-391.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Metal release from simulated fixed orthodontic appliances

AU - Hwang, ChungJu

AU - Shin, Ji Soo

AU - Cha, Jung Yul

PY - 2001/1/1

Y1 - 2001/1/1

N2 - Most orthodontic appliances and archwires are stainless steel or nickel-titanium (NiTi) alloys that can release metal ions, with saliva as the medium. To measure metal released from the fixed orthodontic appliances currently in use, we fabricated simulated fixed orthodontic appliances that corresponded to half of the maxillary arch and soaked them in 50 mL of artificial saliva (pH 6.75 ± 0.15, 37°C) for 3 months. We used brackets, tubes, and bands made by Tomy (Tokyo, Japan). Four groups were established according to the appliance manufacturer and the type of metal in the .016 × .022-in archwires. Groups A and B were stainless steel archwires from Ormco (Glendora, Calif) and Dentaurum (Ispringen, Germany), respectively, and groups C and D were both NiTi archwires with Ormco’s copper NiTi and Tomy’s Bioforce sentalloy, respectively. Stainless steel archwires were heat treated in an electric furnace at 500°C for 1 minute and quenched in water. We measured the amount of metal released from each group by immersion time. Our conclusions were as follows: (1) there was no increase in the amount of chromium released after 4 weeks in group A, 2 weeks in group B, 3 weeks in group C, and 8 weeks in group D; (2) there was no increase in the amount of nickel released after 2 weeks in group A, 3 days in group B, 7 days in group C, and 3 weeks in group D; and (3) there was no increase in the amount of iron released after 2 weeks in group A, 3 days in group B, and 1 day in groups C and D. In our 3-month-long investigation, we saw a decrease in metal released as immersion time increased.

AB - Most orthodontic appliances and archwires are stainless steel or nickel-titanium (NiTi) alloys that can release metal ions, with saliva as the medium. To measure metal released from the fixed orthodontic appliances currently in use, we fabricated simulated fixed orthodontic appliances that corresponded to half of the maxillary arch and soaked them in 50 mL of artificial saliva (pH 6.75 ± 0.15, 37°C) for 3 months. We used brackets, tubes, and bands made by Tomy (Tokyo, Japan). Four groups were established according to the appliance manufacturer and the type of metal in the .016 × .022-in archwires. Groups A and B were stainless steel archwires from Ormco (Glendora, Calif) and Dentaurum (Ispringen, Germany), respectively, and groups C and D were both NiTi archwires with Ormco’s copper NiTi and Tomy’s Bioforce sentalloy, respectively. Stainless steel archwires were heat treated in an electric furnace at 500°C for 1 minute and quenched in water. We measured the amount of metal released from each group by immersion time. Our conclusions were as follows: (1) there was no increase in the amount of chromium released after 4 weeks in group A, 2 weeks in group B, 3 weeks in group C, and 8 weeks in group D; (2) there was no increase in the amount of nickel released after 2 weeks in group A, 3 days in group B, 7 days in group C, and 3 weeks in group D; and (3) there was no increase in the amount of iron released after 2 weeks in group A, 3 days in group B, and 1 day in groups C and D. In our 3-month-long investigation, we saw a decrease in metal released as immersion time increased.

UR - http://www.scopus.com/inward/record.url?scp=0035487472&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035487472&partnerID=8YFLogxK

U2 - 10.1067/mod.2001.117911

DO - 10.1067/mod.2001.117911

M3 - Article

VL - 120

SP - 383

EP - 391

JO - American Journal of Orthodontics and Dentofacial Orthopedics

JF - American Journal of Orthodontics and Dentofacial Orthopedics

SN - 0889-5406

IS - 4

ER -