To assess the clinical utility of the breath-hold turbo spin-echo T2- weighted MRI in patients with acute myocardial infarction, the results of MRI were compared with those of electrocardiography, coronary angiography, and thallium-201 single photon emission tomography (SPECT) in 23 patients and 5 healthy volunteers. To compare MRI and thallium-SPECT, the left ventricle was divided into five segments, and the presence of myocardial infarction was determined in each segment. MR/demonstrated an abnormally bright signal in 49 of 140 segments (five segments each from 23 patients and 5 volunteers); thallium-SPECT showed a fixed perfusion defect in 52 segments, for an 85% diagnostic concordance rate. The size of the myocardial infarction measured on MRI corresponded well to that measured on thallium-SPECT (r = .70, P < .01). Breath-hold turbo spin-echo T2 MRI can be used for detection of acute myocardial infarction in conjunction with thallium-SPECT, especially when accurate localization of lesion, increased spatial resolution, and anatomic landmarks are needed.

Original languageEnglish
Pages (from-to)996-1001
Number of pages6
JournalJournal of Magnetic Resonance Imaging
Volume7
Issue number6
DOIs
Publication statusPublished - 1997 Nov 1

Fingerprint

Thallium
Single-Photon Emission-Computed Tomography
Myocardial Infarction
Anatomic Landmarks
Coronary Angiography
Photons
Heart Ventricles
Volunteers
Healthy Volunteers
Electrocardiography
Perfusion
Tomography

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Cite this

Lim, Tae Hwan ; Hong, Myeongki ; Lee, Jin Seong ; Mun, Chi Woong ; Park, Seung Jung ; Park, Seong Wook ; Ryu, Jin Sook ; Lee, Jung Hee ; Chien, Daisy ; Laub, Gerhard. / Novel application of breath-hold turbo spin-echo T2 MRI for detection of acute myocardial infarction. In: Journal of Magnetic Resonance Imaging. 1997 ; Vol. 7, No. 6. pp. 996-1001.
@article{a246fcdb16e54b978ffee90edb3ccfe0,
title = "Novel application of breath-hold turbo spin-echo T2 MRI for detection of acute myocardial infarction",
abstract = "To assess the clinical utility of the breath-hold turbo spin-echo T2- weighted MRI in patients with acute myocardial infarction, the results of MRI were compared with those of electrocardiography, coronary angiography, and thallium-201 single photon emission tomography (SPECT) in 23 patients and 5 healthy volunteers. To compare MRI and thallium-SPECT, the left ventricle was divided into five segments, and the presence of myocardial infarction was determined in each segment. MR/demonstrated an abnormally bright signal in 49 of 140 segments (five segments each from 23 patients and 5 volunteers); thallium-SPECT showed a fixed perfusion defect in 52 segments, for an 85{\%} diagnostic concordance rate. The size of the myocardial infarction measured on MRI corresponded well to that measured on thallium-SPECT (r = .70, P < .01). Breath-hold turbo spin-echo T2 MRI can be used for detection of acute myocardial infarction in conjunction with thallium-SPECT, especially when accurate localization of lesion, increased spatial resolution, and anatomic landmarks are needed.",
author = "Lim, {Tae Hwan} and Myeongki Hong and Lee, {Jin Seong} and Mun, {Chi Woong} and Park, {Seung Jung} and Park, {Seong Wook} and Ryu, {Jin Sook} and Lee, {Jung Hee} and Daisy Chien and Gerhard Laub",
year = "1997",
month = "11",
day = "1",
doi = "10.1002/jmri.1880070611",
language = "English",
volume = "7",
pages = "996--1001",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "6",

}

Lim, TH, Hong, M, Lee, JS, Mun, CW, Park, SJ, Park, SW, Ryu, JS, Lee, JH, Chien, D & Laub, G 1997, 'Novel application of breath-hold turbo spin-echo T2 MRI for detection of acute myocardial infarction', Journal of Magnetic Resonance Imaging, vol. 7, no. 6, pp. 996-1001. https://doi.org/10.1002/jmri.1880070611

Novel application of breath-hold turbo spin-echo T2 MRI for detection of acute myocardial infarction. / Lim, Tae Hwan; Hong, Myeongki; Lee, Jin Seong; Mun, Chi Woong; Park, Seung Jung; Park, Seong Wook; Ryu, Jin Sook; Lee, Jung Hee; Chien, Daisy; Laub, Gerhard.

In: Journal of Magnetic Resonance Imaging, Vol. 7, No. 6, 01.11.1997, p. 996-1001.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Novel application of breath-hold turbo spin-echo T2 MRI for detection of acute myocardial infarction

AU - Lim, Tae Hwan

AU - Hong, Myeongki

AU - Lee, Jin Seong

AU - Mun, Chi Woong

AU - Park, Seung Jung

AU - Park, Seong Wook

AU - Ryu, Jin Sook

AU - Lee, Jung Hee

AU - Chien, Daisy

AU - Laub, Gerhard

PY - 1997/11/1

Y1 - 1997/11/1

N2 - To assess the clinical utility of the breath-hold turbo spin-echo T2- weighted MRI in patients with acute myocardial infarction, the results of MRI were compared with those of electrocardiography, coronary angiography, and thallium-201 single photon emission tomography (SPECT) in 23 patients and 5 healthy volunteers. To compare MRI and thallium-SPECT, the left ventricle was divided into five segments, and the presence of myocardial infarction was determined in each segment. MR/demonstrated an abnormally bright signal in 49 of 140 segments (five segments each from 23 patients and 5 volunteers); thallium-SPECT showed a fixed perfusion defect in 52 segments, for an 85% diagnostic concordance rate. The size of the myocardial infarction measured on MRI corresponded well to that measured on thallium-SPECT (r = .70, P < .01). Breath-hold turbo spin-echo T2 MRI can be used for detection of acute myocardial infarction in conjunction with thallium-SPECT, especially when accurate localization of lesion, increased spatial resolution, and anatomic landmarks are needed.

AB - To assess the clinical utility of the breath-hold turbo spin-echo T2- weighted MRI in patients with acute myocardial infarction, the results of MRI were compared with those of electrocardiography, coronary angiography, and thallium-201 single photon emission tomography (SPECT) in 23 patients and 5 healthy volunteers. To compare MRI and thallium-SPECT, the left ventricle was divided into five segments, and the presence of myocardial infarction was determined in each segment. MR/demonstrated an abnormally bright signal in 49 of 140 segments (five segments each from 23 patients and 5 volunteers); thallium-SPECT showed a fixed perfusion defect in 52 segments, for an 85% diagnostic concordance rate. The size of the myocardial infarction measured on MRI corresponded well to that measured on thallium-SPECT (r = .70, P < .01). Breath-hold turbo spin-echo T2 MRI can be used for detection of acute myocardial infarction in conjunction with thallium-SPECT, especially when accurate localization of lesion, increased spatial resolution, and anatomic landmarks are needed.

UR - http://www.scopus.com/inward/record.url?scp=13144261674&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=13144261674&partnerID=8YFLogxK

U2 - 10.1002/jmri.1880070611

DO - 10.1002/jmri.1880070611

M3 - Article

VL - 7

SP - 996

EP - 1001

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 6

ER -