Numerical simulation of Y-type perfobond rib shear connectors using finite element analysis

Kun Soo Kim, Oneil Han, Munkhtulga Gombosuren, Sang Hyo Kim

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

This study presents finite element analysis (FEA) on a Y-type perfobond rib shear connection using Abaqus software. The performance of a shear connection is evaluated by conducting a push-out test. However, in practice, it is inefficient to verify the performance by conducting a push-out test with regard to all design variables pertaining to a shear connector. To overcome this problem, FEA is conducted on various shear connectors to accurately estimate the shear strength of the Y-type perfobond rib shear connection. Previous push-out test results for 14 typical push-out test specimens and those obtained through FEA are compared to analyze the shear behavior including consideration of the design variables. The results show that the developed finite element model successfully reflects the effects of changes in the design variables. In addition, using the developed FEA model, the shear resistance of a stubby Y-type perfobond rib shear connector is evaluated based on the concrete strength and transverse rebar size variables. Then, the existing shear resistance formula is upgraded based on the FEA results.

Original languageEnglish
Pages (from-to)53-67
Number of pages15
JournalSteel and Composite Structures
Volume31
Issue number1
DOIs
Publication statusPublished - 2019 Jan 1

Fingerprint

Finite element method
Computer simulation
Shear strength
Concretes

All Science Journal Classification (ASJC) codes

  • Civil and Structural Engineering
  • Building and Construction
  • Metals and Alloys

Cite this

Kim, Kun Soo ; Han, Oneil ; Gombosuren, Munkhtulga ; Kim, Sang Hyo. / Numerical simulation of Y-type perfobond rib shear connectors using finite element analysis. In: Steel and Composite Structures. 2019 ; Vol. 31, No. 1. pp. 53-67.
@article{99dc430817dc4048890dd9245a6b5f23,
title = "Numerical simulation of Y-type perfobond rib shear connectors using finite element analysis",
abstract = "This study presents finite element analysis (FEA) on a Y-type perfobond rib shear connection using Abaqus software. The performance of a shear connection is evaluated by conducting a push-out test. However, in practice, it is inefficient to verify the performance by conducting a push-out test with regard to all design variables pertaining to a shear connector. To overcome this problem, FEA is conducted on various shear connectors to accurately estimate the shear strength of the Y-type perfobond rib shear connection. Previous push-out test results for 14 typical push-out test specimens and those obtained through FEA are compared to analyze the shear behavior including consideration of the design variables. The results show that the developed finite element model successfully reflects the effects of changes in the design variables. In addition, using the developed FEA model, the shear resistance of a stubby Y-type perfobond rib shear connector is evaluated based on the concrete strength and transverse rebar size variables. Then, the existing shear resistance formula is upgraded based on the FEA results.",
author = "Kim, {Kun Soo} and Oneil Han and Munkhtulga Gombosuren and Kim, {Sang Hyo}",
year = "2019",
month = "1",
day = "1",
doi = "10.12989/scs.2019.31.1.053",
language = "English",
volume = "31",
pages = "53--67",
journal = "Steel and Composite Structures",
issn = "1229-9367",
publisher = "Techno Press",
number = "1",

}

Numerical simulation of Y-type perfobond rib shear connectors using finite element analysis. / Kim, Kun Soo; Han, Oneil; Gombosuren, Munkhtulga; Kim, Sang Hyo.

In: Steel and Composite Structures, Vol. 31, No. 1, 01.01.2019, p. 53-67.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Numerical simulation of Y-type perfobond rib shear connectors using finite element analysis

AU - Kim, Kun Soo

AU - Han, Oneil

AU - Gombosuren, Munkhtulga

AU - Kim, Sang Hyo

PY - 2019/1/1

Y1 - 2019/1/1

N2 - This study presents finite element analysis (FEA) on a Y-type perfobond rib shear connection using Abaqus software. The performance of a shear connection is evaluated by conducting a push-out test. However, in practice, it is inefficient to verify the performance by conducting a push-out test with regard to all design variables pertaining to a shear connector. To overcome this problem, FEA is conducted on various shear connectors to accurately estimate the shear strength of the Y-type perfobond rib shear connection. Previous push-out test results for 14 typical push-out test specimens and those obtained through FEA are compared to analyze the shear behavior including consideration of the design variables. The results show that the developed finite element model successfully reflects the effects of changes in the design variables. In addition, using the developed FEA model, the shear resistance of a stubby Y-type perfobond rib shear connector is evaluated based on the concrete strength and transverse rebar size variables. Then, the existing shear resistance formula is upgraded based on the FEA results.

AB - This study presents finite element analysis (FEA) on a Y-type perfobond rib shear connection using Abaqus software. The performance of a shear connection is evaluated by conducting a push-out test. However, in practice, it is inefficient to verify the performance by conducting a push-out test with regard to all design variables pertaining to a shear connector. To overcome this problem, FEA is conducted on various shear connectors to accurately estimate the shear strength of the Y-type perfobond rib shear connection. Previous push-out test results for 14 typical push-out test specimens and those obtained through FEA are compared to analyze the shear behavior including consideration of the design variables. The results show that the developed finite element model successfully reflects the effects of changes in the design variables. In addition, using the developed FEA model, the shear resistance of a stubby Y-type perfobond rib shear connector is evaluated based on the concrete strength and transverse rebar size variables. Then, the existing shear resistance formula is upgraded based on the FEA results.

UR - http://www.scopus.com/inward/record.url?scp=85065254890&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85065254890&partnerID=8YFLogxK

U2 - 10.12989/scs.2019.31.1.053

DO - 10.12989/scs.2019.31.1.053

M3 - Article

AN - SCOPUS:85065254890

VL - 31

SP - 53

EP - 67

JO - Steel and Composite Structures

JF - Steel and Composite Structures

SN - 1229-9367

IS - 1

ER -