On the possibility of biosensors based on split ring resonators

Hee Jo Lee, Hyun Seok Lee, Kyung Hwa Yoo, Jong Gwan Yook

Research output: Chapter in Book/Report/Conference proceedingConference contribution

12 Citations (Scopus)

Abstract

An investigation on the feasibility of a biosensor based on split ring resonator (SRR) is reported in this paper. A two-pair SRR array is used for the biosensor device. The compact SRR composite is excited by a microstrip transmission line which can generate the quasi-TEM mode. The device showed sensitivity to the biosensing parameters of S21 resonant frequency and loaded Q values, due to the coupling of nano-size biomaterials. The feasibility of and the applications for a biosensor based on based on SRRs are also briefly discussed.

Original languageEnglish
Title of host publicationProceedings of the 38th European Microwave Conference, EuMC 2008
Pages1222-1225
Number of pages4
DOIs
Publication statusPublished - 2008
Event38th European Microwave Conference, EuMC 2008 - Amsterdam, Netherlands
Duration: 2008 Oct 272008 Oct 31

Publication series

NameProceedings of the 38th European Microwave Conference, EuMC 2008

Other

Other38th European Microwave Conference, EuMC 2008
CountryNetherlands
CityAmsterdam
Period08/10/2708/10/31

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering

Fingerprint Dive into the research topics of 'On the possibility of biosensors based on split ring resonators'. Together they form a unique fingerprint.

  • Cite this

    Lee, H. J., Lee, H. S., Yoo, K. H., & Yook, J. G. (2008). On the possibility of biosensors based on split ring resonators. In Proceedings of the 38th European Microwave Conference, EuMC 2008 (pp. 1222-1225). [4751681] (Proceedings of the 38th European Microwave Conference, EuMC 2008). https://doi.org/10.1109/EUMC.2008.4751681