T1 - Optical coherence tomography analysis of strut coverage in biolimus- and sirolimus-eluting stents
T2 - 3-Month and 12-month serial follow-up
AU - Kim, Byeong Keuk
AU - Hong, Myeong Ki
AU - Shin, Dong Ho
AU - Kim, Jung Sun
AU - Ko, Young Guk
AU - Choi, Donghoon
AU - Jang, Yangsoo
N1 - Copyright:
Copyright 2013 Elsevier B.V., All rights reserved.
PY - 2013/10/12
Y1 - 2013/10/12
N2 - Background No randomized studies have been conducted to investigate serial changes in optical coherence tomography (OCT) analyses following implantation of biolimus-A9-eluting stents (BES) and sirolimus-eluting stents (SES). Methods A total of 60 patients fulfilling the study criteria were randomly assigned into BES (n = 30) and SES (n = 30) implantation groups. Serial OCT evaluation at post-procedure, 3- and 12-month follow-up was performed in 46 patients [BES (n = 22) and SES (n = 24)]. OCT analyses were compared according to the type of stents and the follow-up time intervals. The percentage of uncovered struts was defined as the ratio of uncovered struts to total struts in all cross-sections. The primary endpoint was the percentage change (Δ) of uncovered struts in the 3- and 12-month follow-up samples. Results The percentage of uncovered struts at the 3-month time period was not significantly different in the BES and SES groups; the median value (interquartile range) was 14.7% (0.0-23.4) versus 8.6% (0.7-21.5) (p = 0.98), respectively. However, OCT at the 12-month follow-up showed a significantly lower percentage of uncovered struts [2.6% (0.8-5.6) versus 6.2% (1.7-14.7), (p = 0.028), respectively] without significant difference of neointimal thickness. BES showed a greater reduction of percentage Δ of uncovered struts from 3-12 months than that of SES [- 17.2 ± 14.5% versus - 7.7 ± 16.3%, respectively (p = 0.043)]. Conclusions Both drug-eluting stents showed a high percentage of incomplete strut coverage at 3 months. However, BES showed a significantly lower percentage of uncovered struts at 12 months compared to that of SES. This was achieved by superior strut coverage from 3 to 12 months.
AB - Background No randomized studies have been conducted to investigate serial changes in optical coherence tomography (OCT) analyses following implantation of biolimus-A9-eluting stents (BES) and sirolimus-eluting stents (SES). Methods A total of 60 patients fulfilling the study criteria were randomly assigned into BES (n = 30) and SES (n = 30) implantation groups. Serial OCT evaluation at post-procedure, 3- and 12-month follow-up was performed in 46 patients [BES (n = 22) and SES (n = 24)]. OCT analyses were compared according to the type of stents and the follow-up time intervals. The percentage of uncovered struts was defined as the ratio of uncovered struts to total struts in all cross-sections. The primary endpoint was the percentage change (Δ) of uncovered struts in the 3- and 12-month follow-up samples. Results The percentage of uncovered struts at the 3-month time period was not significantly different in the BES and SES groups; the median value (interquartile range) was 14.7% (0.0-23.4) versus 8.6% (0.7-21.5) (p = 0.98), respectively. However, OCT at the 12-month follow-up showed a significantly lower percentage of uncovered struts [2.6% (0.8-5.6) versus 6.2% (1.7-14.7), (p = 0.028), respectively] without significant difference of neointimal thickness. BES showed a greater reduction of percentage Δ of uncovered struts from 3-12 months than that of SES [- 17.2 ± 14.5% versus - 7.7 ± 16.3%, respectively (p = 0.043)]. Conclusions Both drug-eluting stents showed a high percentage of incomplete strut coverage at 3 months. However, BES showed a significantly lower percentage of uncovered struts at 12 months compared to that of SES. This was achieved by superior strut coverage from 3 to 12 months.
UR - http://www.scopus.com/inward/record.url?scp=84886397754&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84886397754&partnerID=8YFLogxK
U2 - 10.1016/j.ijcard.2013.07.160
DO - 10.1016/j.ijcard.2013.07.160
M3 - Article
C2 - 23932862
AN - SCOPUS:84886397754
VL - 168
SP - 4617
EP - 4623
JO - International Journal of Cardiology
JF - International Journal of Cardiology
SN - 0167-5273
IS - 5
ER -